background image

INSTRUCTIONS FOR:

12V ROADSTART UniT 

MODEL No: 

RS131.V2

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions 
and properly maintained, give you years of trouble free performance.

IMPORTANT: BEFORE USinG THiS PRODUCT, PLEASE READ THE inSTRUCTiOnS CAREFULLY. MAKE CAREFUL nOTE OF SAFETY inSTRUCTiOnS, WARninGS 
AnD CAUTiOnS. THiS PRODUCT SHOULD OnLY BE USED FOR iTS inTEnDED PURPOSE. FAiLURE TO FOLLOW THESE inSTRUCTiOnS MAY CAUSE DAMAGE 
AnD/OR PERSOnAL inJURY AnD WiLL inVALiDATE THE WARRAnTY. RETAin THESE inSTRUCTiOnS FOR FUTURE USE.

  1.  FEATURES

IMPORTANT: 

To reduce the risk of a battery explosion, follow these instructions and those published by the battery manufacturer and the manu-

facturer of any equipment you intend to use in the vicinity of the battery. Remember to review warning marks on all products and on engines.

3.1. 

PERSOnAL PRECAUTiOnS

  Ensure there is another person within hearing range, or close enough to come to your aid should a problem arise, when working near 

 

a lead-acid battery.

  Have fresh water and soap nearby in case battery acid contacts skin, clothing or eyes.

  Wear safety eye protection and protective clothing. Avoid touching eyes while working with a battery.

  Wash immediately with soap and water if battery acid contacts skin or clothing. If acid enters eye, flush eye immediately with cool, clean 

 

running water for at least 15 minutes and seek immediate medical attention.

  Remove personal metallic items such as rings, bracelets, necklaces and watches. A lead-acid battery can produce a short-circuit current 

 

high enough to weld a ring or the like to metal, which may cause severe burns.

3.2. 

OTHER iMPORTAnT RS131 SAFETY inSTRUCTiOnS

  Familiarise yourself with the applications, limitations and potential hazards of the Roadstart.

  Keep the unit in good working order and condition (take immediate action to repair or replace damaged parts).

  Use only recommended parts. To use unapproved parts may be dangerous and will invalidate your warranty. 

  The Roadstart must only be opened and checked by qualified service personnel. 

DO nOT

 disassemble the RS131 for any reason. 

  Keep children and unauthorised persons away from the work area.

  Keep work area clean and tidy and free from unrelated materials. Ensure that there is adequate lighting.

  If the RS131 receives a sharp knock or blow, it must be checked by a qualified service agent before being used.

  When not in use re-charge every six months. 

 

DO nOT

 smoke or allow a spark, or flame in the vicinity of the battery or engine.

 

DO nOT

 drop any metal tool onto the battery as it may spark or short circuit the battery, which could cause an explosion. 

 

DO nOT

 use RS131 to recharge dry cell batteries that are commonly used with home appliances. These batteries may burst and cause

 

injury to persons and/or damage to property.   

 

 

DO nOT

 charge or boost a frozen battery.

 

DO nOT

 recharge the unit for more than 36 hours continuously. 

 

DO nOT

 use attachments other than those recommended. To do so may risk damage to the unit and other equipment and possible personal 

injury. 

 

DO nOT

 pull or carry the RS131 by its cables and do not pull the negative and positive clamps from the battery terminals.

 

DO nOT

 operate in vicinity of flammable liquids or gases.

 

DO nOT

 recharge the RS131 with plugs, cables or attachments that are damaged. Replace such items immediately.

 

DO nOT

 use this product to perform a task for which it is not designed.

  3.   SAFETY inSTRUCTiOnS

 

DANGER! - RISK OF EXPLOSIVE GASES.

WORKING IN THE VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY 
OPERATION. FOR THIS REASON, IT IS VERY IMPORTANT TO READ AND FOLLOW EXACTLY THESE INSTRUCTIONS, EACH TIME YOU  USE THE RS131.

1.1.  GEnERAL FEATURES

  600 amps initial peak power for starting. May also be used in DEEP CYCLE applications.

  The Roadstart is also a portable power source for 12V DC accessories equipped 

 

with a male cigarette lighter plug. The DC outlet has thermal cut-out protection.

  Test switch and LEDs.

 

Integral work light.

1.2.  SAFETY FEATURES

  Clamp storage prevents accidental sparking of clamps. 

  The Roadstart contains the latest technology, a 12 volt sealed battery. This means 

 

that the Roadstart RS131 may be stored in any position without fear of leakage.

IMPORTANT:  READ SAFETY INSTRUCTIONS BEFORE ATTEMPTING TO 
USE THE ROADSTART.

 

Original Language Version

RS131.V2    Issue: 2 - 19/10/09

  2.   SPECiFiCATiOn

 Built-in Battery  . . . . . . . .Sealed, maintenance free, re-chargeable. 

 DC Output . . . . . . . . . . . .12 volts.
 Boost Rate  . . . . . . . . . . .900 amps (peak).
 Cold Cranking Current  . .250 amps.
 Charging Time  . . . . . . . .Approximately 20 hours with AC charging
  

adaptor & approximately 11 hours with DC   

 

charging cable.

 Battery Capacity . . . . . . .18Ah.

 Thermal Cut-out  . . . . . . .12 amp.
 Light Bulb  . . . . . . . . . . . .12V 3W.
 Weight. . . . . . . . . . . . . . .5.5kg.
 Dimensions . . . . . . . . . . .245 x 275 x 145mm.