INSTRUCTIONS FOR:
ELECTRIC OIL FILLED HEATERS
RD1500.V5, RD2500.V5
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
1.
SAFETY INSTRUCTIONS
IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE OR PERSONAL INJURY, AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1.2.
GENERAL SAFETY
!
WARNING!
Disconnect the heater from the mains power, before servicing or performing any maintenance, which must only be carried out
by an authorised service agent. Report any oil leakage immediately to an authorised service agent.
"
Replace or repair damaged parts.
Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
"
Ensure that the heater is used in an area larger than 4m
3
.
Allow a few centimetres of clearance from any surface, and ensure there is
good overhead clearance for heat circulation.
"
Only use the heater in an upright position.
!
!
WARNING!
do not tamper with the wiring, heating element or oil. The system is a sealed unit. The
breaking of any seal may be dangerous, will damage the heater and will invalidate the warranty.
#
DO NOT use the heater for anything other than its intended purpose. It is designed for providing
heat in enclosed areas, no smaller than 4m
3
, such as offices, homes, workshops etc. It is not
suitable for drying clothes or laundry.
#
DO NOT place the heater close to a bath, wash basin, shower, swimming pool or any other
water-filled area or wet surface. DO NOT get the heater wet or use in areas of high condensation.
#
DO NOT place the heater up against any surface such as a wall, door, furniture etc.
#
DO NOT place the heater immediately below any electrical outlet.
#
DO NOT allow the power lead to touch the radiator surface.
#
DO NOT cover the radiator or use it to dry laundry.
#
DO NOT switch the heater on whilst the electrical lead is wrapped on the storage bracket.
#
DO NOT store the electrical lead until the radiator is cold.
#
DO NOT attempt to repair a damaged heater, contact an authorised service agent.
#
DO NOT stand on the heater.
#
DO NOT touch the heating elements when the heater is on as it becomes very hot.
1.1.
ELECTRICAL SAFETY
!
WARNING!
It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other
connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices.
A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current
Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected
by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer.
You must
also read and understand the following instructions concerning electrical safety.
1.1.1. The
Electricity at Work Act 1989
requires all portable electrical appliances, if used on business premises, to be tested by a qualified
electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.1.2. The
Health & Safety at Work Act 1974
makes owners of electrical appliances responsible for the safe condition of those appliances
and the safety of the appliance operators.
If in any doubt about electrical safety, contact a qualified electrician.
1.1.3. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2.
and use a Portable Appliance Tester.
1.1.4. Ensure that cables are always protected against short circuit and overload.
1.1.5. Regularly inspect power supply cables and plugs for wear or damage and check all
connections to ensure that none is loose.
1.1.6.
Important:
Ensure that the voltage marked on the appliance matches the power supply
to be used and that the plug is fitted with the correct fuse - see fuse rating at right.
1.1.7.
DO NOT
pull or carry the appliance by the power cable.
1.1.8.
DO NOT
pull the plug from the socket by the cable.
1.1.9.
DO NOT
use worn or damaged cables, plugs or connectors. Immediately have any faulty
item repaired or replaced by a qualified electrician. When an ASTA/BS approved UK
3 pin plug is damaged, cut the cable just above the plug and
dispose of the plug safely.
Fit a new plug according to the following instructions (UK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation
extends beyond the cable restraint and that the restraint is tight.
Double insulated products, which are always marked with this symbol , are fitted with live (brown) and neutral (blue) wires only.
To rewire, connect the wires as indicated above -
DO NOT
connect either wire to the earth terminal.
1.1.10. Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure that a
suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket with your electrician.
1.1.11. If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance
plugged into it will be protected. The cable core section is important and should be at least 1.5mm
2
, but to be absolutely sure that the
capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use of
2.5mm
2
section cable.
1.1.12.
DO NOT move the heater whilst it is ON, always disconnect from the supply and allow to cool first.
FUSE RATING RD1500.V5 - 10 AMP
FUSE RATING RD2500.V5 - 13 AMP
Blue
Neutral
Wire
Yellow & Green
Earth Wire
Cable
Restraint
Brown
Live
Wire
RD1500.V5, RD2500.V5 - 1 - 010607