background image

  1.  SAFETY INSTRUCTIONS

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. 

USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE 

DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions 

and properly maintained, give you years of trouble free performance.

INSTRUCTIONS FOR:

SHOT BLASTING CABINET

MODEL No:

 

SB970.V3

1.1.  

ELECTRICAL  SAFETY 

REGARDING DIRECT MAINS POWER USE WITH THE TRANSFORMER PLUG.

 

WARNING!

 It is the user’s responsibility to read, understand and comply with the following electrical instructions:

You must ensure the risk of electric shock is minimised by the installation of appropriate safety devices. An RCCB (Residual Current Circuit 

Breaker) should be incorporated in the main distribution board. We also recommend that an RCD (Residual Current Device) is used with all 

electrical products, particularly portable equipment which is plugged into an electrical supply not protected by an RCCB.

You must

 also read and understand the following instructions concerning electrical safety:

1.1.1.

 The 

Electricity At Work Act 1989

 requires all portable electrical appliances, if used on business premises, to be tested by

 

 

a qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2.

 The 

Health & Safety at Work Act 1974

 makes owners of electrical appliances responsible for the safe condition of the appliance 

 

 

and the safety of the appliance operator. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3.

 

You must ensure that you:

  Inspect the transformer plug, cable, and plug for wear and damage to ensure items are safe before connecting to the mains power supply.  If  

 

worn or damaged 

DO NOT

 use and immediately replace, or contact a qualified electrician.

  Check cables are always protected against short circuit and overload.

 

Important:

 Check that the voltage marked on the transformer plug is the same as the power supply to be used.

  Uncoil the lead from the transformer before use.

 

DO NOT

 attempt to pull the transformer plug from the mains socket by the lead.

 

DO NOT

 use any other type of transformer with the cabinet. 

 

DO NOT

 try to open or disassemble the transformer plug or charging base.

 

DO NOT

 use the transformer plug to power any other electrical item.

 

DO NOT

 get the transformer wet, or use in wet, damp conditions (for indoor use only).

 

WARNING!

 

NEVER

 substitute a standard 13Amp 3 pin plug, or any other type of plug, for the transformer plug .

1.2  

GENERAL SAFETY

 

WARNING!

 Ensure Health & Safety, government and local authority regulations relating to the the use of shot blasting are adhered to when

 

using this equipment. Familiarise yourself with the applications, limitations and potential hazards peculiar to the cabinet.

 

WARNING!

 

Disconnect the cabinet from the mains power and the air supply before attempting to change accessories or carry out any    

 

servicing or maintenance.

 

Maintain the

 

cabinet in good condition Replace or repair damaged parts. 

Use genuine parts only. Unauthorised parts may be dangerous 

 

and will invalidate the warranty.

 

Locate cabinet in a suitable work area and keep area clean, tidy and free from unrelated materials. Ensure there is adequate lighting.

 

Use only dry abrasives such as proprietary brands of glass beads, silicon carbide, aluminium oxide and silica sand. We recommend Sealey  

 

item B5KG. Never use fluids or mix fluids with another media in the unit.

 

WARNING! 

Always wear approved eye or face and ear protection when operating the cabinet. 

 

Keep the unit lid closed and secured when in use.

 

WARNING!

 Ensure correct air pressure is maintained and not exceeded. (Max 90psi).

 

Always keep the blast nozzle directed at the workpiece. Never use outside the unit and always use with the lid closed.

 

Regularly check that the exhaust vent at the back of the cabinet is clear and not blocked and that there is space between it and any wall.

 

Maintain correct balance and footing. Ensure the floor is clean and free from blasting media spillage. Wear non-slip shoes.

 

Remove ill fitting clothing. Remove ties, watches, rings, and other loose jewellery and contain and/or tie back long hair.

 

Keep children and non-essential persons away from the work area.

 

DO NOT

 use the cabinet for a task it is not designed to perform.

 

DO NOT

 operate the cabinet if any parts are damaged or missing as this may cause failure and/or personal injury.

 

DO NOT

 operate the cabinet with the lid open.

 

DO NOT

 stand on the cabinet.

 

DO NOT

 get the cabinet wet or use in damp or wet locations or areas where there is condensation.

 

DO NOT

 operate the cabinet when you are tired or under the influence of alcohol, drugs or intoxicating medication.

 

DO NOT

 leave the cabinet operating unattended.

  When not in use disconnect from the electrical mains and the air supply.

NOTE! We strongly recommend that a suitable dust extraction system is used with this unit.

If dust extraction is not used, media may be forced out of the joints as pressure builds up. You can alleviate this to some extent 

by removing the white blanking plug (Fig.1) situated on the upper left corner at the rear of the tank when viewed from the front. 

This however will not substitute a suitable dust extraction system. 

Original Language Version

SB970.V3    Issue: 1 - 25/07/13

© Jack Sealey Limited 