background image

InstructIons for: 

AIr regulAtor, FIlter, luBrICAtor rANge 

Models: 

SA206, SA206Fr, SA206F, SA206l, SA206r, 

SA206FrAD, SA206FAD.

thank  you  for  purchasing  a  sealey  product.  Manufactured  to  a  high  standard  this  product  will,  if  used  according  to  these  instructions 

and properly maintained, give you years of trouble free performance.

1.  SAFetY INStruCtIoNS

IMPORTANT:

 

PleASe reAD tHeSe INStruCtIoNS CAreFullY. Note tHe SAFe oPerAtIoNAl reQuIreMeNtS, WArNINgS & CAutIoNS. 

uSe  tHe  ProDuCt  CorreCtlY  AND  WItH  CAre  For  tHe  PurPoSe  For  WHICH  It  IS  INteNDeD.  FAIlure  to  Do  So  MAY  CAuSe 

DAMAge AND/or  PerSoNAl  INJurY AND  WIll  INVAlIDAte  tHe  WArrANtY.  PleASe  KeeP  INStruCtIoNS  SAFe  For  Future  uSe.

 

WArNINg!

 

Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this equipment.

 

WArNINg!

 

Disconnect  the  equipment  from  the  air  supply  before  changing  accessories,  servicing  or  performing  any  maintenance.

 

Keep the equipment clean and maintain it in good condition (use an authorised service agent).

 

replace or repair damaged parts. 

Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

 

WArNINg!

 Ensure that the correct air pressure is maintained and not exceeded. 

 

Keep air hoses away from heat, oil and sharp edges. check hoses for wear before each use and ensure that all connections are secure.

 

Do Not

 direct air from the air hose at yourself, others or animals.

 

Drain the compressor air tank daily. Water in the air line will damage your equipment.

 

When work is complete ensure that the air supply is turned off.

suitable for industrial workshop air supply set-ups where high volume applications are required. regulator assemblies feature locking control 

knob for pre-setting air pressure and large easy-to-read pressure gauge. filters available with manual or auto drain facility with female 

1/8”BsP outlet. Lubricator includes oil/air mix control and sight glass. filter and lubricator are fitted with metal bowl cages for protection. 

sA206, sA206fr, sA206frAD and sA206r supplied with mounting bracket.

2.  INtroDuCtIoN & SPeCIFICAtIoNS

   Filter/lubricator/regulator - SA206

 

Max. inlet pressure . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar)

 

Max. outlet pressure . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar)

 

Max. flow rate @ 100psi (6.9 bar)  . . . . . . . . . . . . . . . .105cfm

  filter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 micron

  Lubricant . . . . . . . .sealey Air tool oil - Ato/500 or Ato/1000

  Ports-Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP

 

outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP

 

Gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4”BsP

  Filter/regulator - SA206Fr, SA206FrAD

 

Max. inlet pressure . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar)

  Max. outlet pressure . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar)

 

Max. flow rate @ 100psi (6.9 bar)  . . . . . . . . . . . . . . . .140cfm

  filter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 micron

  Ports-Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP

 

outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP

 

Gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4”BsP

Auto drain . . . . . . . . . . . . . . . . . . . . . . . . . . sA206frAD only

  regulator - SA206r

 

Max. inlet pressure . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar)

  Max. outlet pressure . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar)

 

Max. flow rate @ 100psi (6.9 bar)  . . . . . . . . . . . . . . . .210cfm

  Ports-Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP

 

outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP

 

Gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4”BsP

  Filter - SA206F, SA206FAD

 

Max. inlet pressure . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar)

  Max. outlet pressure . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar)

 

Max. flow rate @ 100psi (6.9 bar)  . . . . . . . . . . . . . . . .140cfm

  filter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 micron 

  Ports-Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP

 

outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP

Auto drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . sA206fAD only

 

  lubricator - SA206l

 

Max. inlet pressure . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar)

  Max. outlet pressure . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar)

 

Max. flow rate @ 100psi (6.9 bar)  . . . . . . . . . . . . . . . .175cfm 

  Lubricant . . . . . . . .sealey Air tool oil - Ato/500 or Ato/1000

  Ports-Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP

 

outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP

WArNINg! Filter and lubricator bowls are manufactured    

from polycarbonate and must not be used at temperatures   

over 125

°

F (52

°

C) or for pressures over 218psi (15 bar).

Polycarbonate can be damaged and may fail if exposed to  

certain solvents either internally or externally - strong 

alkalies,  compressor oils containing aromatic hydrocarbons  

or fire retardant oils, or the fumes of any of these.  

Clean with warm water only.

SA206

SA206Fr & SA206FrAD

SA206F & SA206FAD

SA206l

SA206r

sA206/206fr/206f/206L/206r/206fAD/206frAD

Issue: 2 - 05/09/08

Reviews: