InstructIons for:
AIr regulAtor, FIlter, luBrICAtor rANge
Models:
SA206, SA206Fr, SA206F, SA206l, SA206r,
SA206FrAD, SA206FAD.
thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
1. SAFetY INStruCtIoNS
IMPORTANT:
PleASe reAD tHeSe INStruCtIoNS CAreFullY. Note tHe SAFe oPerAtIoNAl reQuIreMeNtS, WArNINgS & CAutIoNS.
uSe tHe ProDuCt CorreCtlY AND WItH CAre For tHe PurPoSe For WHICH It IS INteNDeD. FAIlure to Do So MAY CAuSe
DAMAge AND/or PerSoNAl INJurY AND WIll INVAlIDAte tHe WArrANtY. PleASe KeeP INStruCtIoNS SAFe For Future uSe.
WArNINg!
Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this equipment.
WArNINg!
Disconnect the equipment from the air supply before changing accessories, servicing or performing any maintenance.
Keep the equipment clean and maintain it in good condition (use an authorised service agent).
replace or repair damaged parts.
Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
WArNINg!
Ensure that the correct air pressure is maintained and not exceeded.
Keep air hoses away from heat, oil and sharp edges. check hoses for wear before each use and ensure that all connections are secure.
Do Not
direct air from the air hose at yourself, others or animals.
Drain the compressor air tank daily. Water in the air line will damage your equipment.
When work is complete ensure that the air supply is turned off.
suitable for industrial workshop air supply set-ups where high volume applications are required. regulator assemblies feature locking control
knob for pre-setting air pressure and large easy-to-read pressure gauge. filters available with manual or auto drain facility with female
1/8”BsP outlet. Lubricator includes oil/air mix control and sight glass. filter and lubricator are fitted with metal bowl cages for protection.
sA206, sA206fr, sA206frAD and sA206r supplied with mounting bracket.
2. INtroDuCtIoN & SPeCIFICAtIoNS
Filter/lubricator/regulator - SA206
Max. inlet pressure . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar)
Max. outlet pressure . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar)
Max. flow rate @ 100psi (6.9 bar) . . . . . . . . . . . . . . . .105cfm
filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 micron
Lubricant . . . . . . . .sealey Air tool oil - Ato/500 or Ato/1000
Ports-Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP
outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP
Gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4”BsP
Filter/regulator - SA206Fr, SA206FrAD
Max. inlet pressure . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar)
Max. outlet pressure . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar)
Max. flow rate @ 100psi (6.9 bar) . . . . . . . . . . . . . . . .140cfm
filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 micron
Ports-Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP
outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP
Gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4”BsP
Auto drain . . . . . . . . . . . . . . . . . . . . . . . . . . sA206frAD only
regulator - SA206r
Max. inlet pressure . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar)
Max. outlet pressure . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar)
Max. flow rate @ 100psi (6.9 bar) . . . . . . . . . . . . . . . .210cfm
Ports-Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP
outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP
Gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4”BsP
Filter - SA206F, SA206FAD
Max. inlet pressure . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar)
Max. outlet pressure . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar)
Max. flow rate @ 100psi (6.9 bar) . . . . . . . . . . . . . . . .140cfm
filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 micron
Ports-Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP
outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP
Auto drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . sA206fAD only
lubricator - SA206l
Max. inlet pressure . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar)
Max. outlet pressure . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar)
Max. flow rate @ 100psi (6.9 bar) . . . . . . . . . . . . . . . .175cfm
Lubricant . . . . . . . .sealey Air tool oil - Ato/500 or Ato/1000
Ports-Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP
outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP
WArNINg! Filter and lubricator bowls are manufactured
from polycarbonate and must not be used at temperatures
over 125
°
F (52
°
C) or for pressures over 218psi (15 bar).
Polycarbonate can be damaged and may fail if exposed to
certain solvents either internally or externally - strong
alkalies, compressor oils containing aromatic hydrocarbons
or fire retardant oils, or the fumes of any of these.
Clean with warm water only.
SA206
SA206Fr & SA206FrAD
SA206F & SA206FAD
SA206l
SA206r
sA206/206fr/206f/206L/206r/206fAD/206frAD
Issue: 2 - 05/09/08