background image

INSTRUCTIONS FOR:  
AIR REGULATOR, FILTER, LUBRICATOR RANGE

Models: 

SA106, SA106FR, SA106F, SA106L, SA106R

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions 
and properly maintained, give you years of trouble free performance.

1.

SAFETY INSTRUCTIONS

IMPORTANT:

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.

USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

!

WARNING!

Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this equipment.

!

WARNING!

Disconnect the equipment from the air supply before changing accessories, servicing or performing any maintenance.

"

Keep the equipment clean and maintain it in good condition (use an authorised service agent).

"

Replace or repair damaged parts. 

Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

!

WARNING!

Ensure that the correct air pressure is maintained and not exceeded. 

"

Keep air hoses away from heat, oil and sharp edges. Check hoses for wear before each use and ensure that all connections are secure.

#

DO NOT

direct air from the air hose at yourself, others or animals.

"

Drain the compressor air tank daily. Water in the air line will damage your equipment.

"

When work is complete ensure that the air supply is turned off.

Suitable for workshop air supply set-ups. Regulator features locking control knob for pre-setting air pressure and pressure gauge. Filter has
manual drain facility with female 1/8”BSP outlet. Lubricator includes oil/air mix control and sight glass. Filter and lubricator are fitted with
metal bowl cages for protection. SA106, SA106FR and SA106R supplied with mounting bracket.

2.

INTRODUCTION & SPECIFICATIONS

Filter/Lubricator/Regulator - SA106

Max. inlet pressure  . . . . . . . . . . . . . . . . . . .150psi (10.3 bar)
Max. outlet pressure  . . . . . . . . . . . . . . . . . . .125psi (8.6 bar)
Max. flow rate @ 100psi (6.9 bar)  . . . . . . . . . . . . . . . .60cfm
Filter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 micron
Lubricant  . . . . . . .Sealey Air Tool Oil - ATO/500 or ATO/1000
Ports-Inlet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4”BSP

Outlet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4”BSP
Gauge  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/8”BSP

Filter/Regulator - SA106FR

Max. inlet pressure  . . . . . . . . . . . . . . . . . . .150psi (10.3 bar)
Max. outlet pressure  . . . . . . . . . . . . . . . . . . .125psi (8.6 bar)
Max. flow rate @ 100psi (6.9 bar)  . . . . . . . . . . . . . . . .70cfm
Filter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 micron
Ports-Inlet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4”BSP

Outlet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4”BSP
Gauge  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/8”BSP

Regulator - SA106R

Max. inlet pressure  . . . . . . . . . . . . . . . . . . .150psi (10.3 bar)
Max. outlet pressure  . . . . . . . . . . . . . . . . . . .125psi (8.6 bar)
Max. flow rate @ 100psi (6.9 bar)  . . . . . . . . . . . . . . . .88cfm
Ports-Inlet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4”BSP

Outlet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4”BSP
Gauge  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/8”BSP

Filter - SA106F

Max. inlet pressure  . . . . . . . . . . . . . . . . . . .150psi (10.3 bar)
Max. outlet pressure  . . . . . . . . . . . . . . . . . . .125psi (8.6 bar)
Max. flow rate @ 100psi (6.9 bar)  . . . . . . . . . . . . . . . .53cfm
Filter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 micron
Ports-Inlet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4”BSP

Outlet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4”BSP

Lubricator - SA106L

Max. inlet pressure  . . . . . . . . . . . . . . . . . . .150psi (10.3 bar)
Max. outlet pressure  . . . . . . . . . . . . . . . . . . .125psi (8.6 bar)
Max. flow rate @ 100psi (6.9 bar)  . . . . . . . . . . . . . . . .60cfm
Lubricant  . . . . . . .Sealey Air Tool Oil - ATO/500 or ATO/1000
Ports-Inlet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4”BSP

Outlet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4”BSP

WARNING! Filter and lubricator bowls are manufactured
from polycarbonate and must not be used at temperatures 
over 125

O

F (52

O

C) or for pressures over 218psi (15 bar).

Polycarbonate can be damaged and may fail if exposed to
certain solvents either internally or externally - strong 
alkalies, compressor oils containing aromatic hydrocarbons 
or fire retardant oils, or the fumes of any of these. 
Clean with warm water only.

SA106/106FR/106F/106L/106R - 1 - 120406

SA106

SA106FR

SA106F

SA106L

SA106R

Reviews: