background image

INSTRUCTIONS FOR:

HAND LAMP C/W GRIPPER

MODEL No:

 

ML100/GP

Thank  you  for  purchasing  a  Sealey  Product.  Manufactured  to  a  high  standard  this  product  will,  if  used  according  to  these 

instructions and properly maintained, give you years of trouble free performance.

IMPORTANT:

   

PLEASE  READ  THESE  INSTRUCTIONS  CAREFULLY.  NOTE  THE  SAFE  OPERATIONAL 

REQUIREMENTS, WARNINGS AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE 

PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY 

AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

1

.

1.  SAFETY

FUSE RATING

THIS PRODUCT MUST BE 

FITTED WITH A 

5

 

AMP FUSE

Cable

restraint

Brown

Live 

wire

Blue 

Neutral 

wire

1.1. 

ELECTRICAL SAFETY.  

  

WARNING!

 It is the user’s responsibility to read, understand and comply as follows. 

You must

 check all electrical  

 

equipment and appliances to ensure they are safe before using. 

You must

 inspect power supply leads, plugs and all  

 

electrical connections for wear and damage. 

You must

 ensure the risk of electric shock is minimised by the installation of  

 

appropriate safety devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution  

 

board. We also recommend that an RCD (Residual Current Device) is used with all electrical products. It is particularly  

 

important to use an RCD  together with portable products that are plugged into an electrical supply not protected by an  

 

RCCB. If in doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your 

 

Sealey dealer. 

You must

 ace operator. If in doubt about electrical safety, contact a qualified electrician.

1.1.3.  Ensure the insulation on all cables and the product itself is safe before connecting to the mains power

 

supply. See 1.1.1. & 1.1.2. above and use a Portable Appliance Tester (PAT).

1.1.4.  Ensure that cables are always protected against short circuit and overload.

1.1.5.  Regularly inspect power supply, leads and plugs for wear and damage and inspect connections to ensure that

 

none is loose. 

1.1.6.  Important: Ensure the voltage marked on the product is the same as the electrical power supply to be used, and check  

 

that plugs are fitted with the correct capacity fuse. A 13 amp plug may require a fuse smaller than 13 amps for certain  

 

products (subject to 1.1.10. below) see fuse rating at right. 

1.1.7.  DO NOT pull or carry the powered appliance by its power supply lead. 

1.1.8.  DO NOT pull power plugs from sockets by the power cable.

1.1.9.  DO NOT use worn or damaged leads, plugs or connections.

 

Immediately replace or have repaired by a qualified electrician.

 

A U.K. 3 pin plug with ASTA/BS approval is fitted. In case of damage,

  

cut off and fit a new plug according to the following instructions (discard 

 

old plug safely). (UK only - see diagram at right). 

 

Ensure the unit is correctly earthed via a three-pin plug. 

 

a) Connect the green/yellow earth wire to the earth terminal ‘E’.

 

b) Connect the brown live wire to live terminal ‘L’.

 

c) Connect the blue neutral wire to the neutral terminal ‘N’.

 

d) After wiring, check that there are no bare wires, that all wires have 

 

    been correctly connected, that the cable outer insulation extends 

 

    beyond the cable resraint and that the restraint is tight.

 

Double insulated products are often fitted with live (BROWN) and 

 

neutral (BLUE) wires only. Double insulated products are always marked 

 

with this symbol      . To re-wire, connect the brown and blue wires as 

 

indicated above. DO NOT connect the brown or blue to the earth terminal.

1.1.10.  Cable extension reels. When a cable extension reel is used it should be fully

 

unwound before connection. A cable reel with an RCD fitted is recommended 

 

since any product which is plugged into the cable reel will be protected.

1.2. 

GENERAL SAFETY

 

WARNING! Disconnect lamp from mains power before changing bulb or  

 

performing any maintenance.

  Replace or repair damaged parts. 

Use genuine Sealey parts only. Non-authorised  

 

parts may be dangerous and will invalidate the warranty.

 

Maintain the lamp in good condition.

 

DO NOT

 use the lamp if damaged.

 

DO NOT

 use lamp close to paint fumes, solvents or other flammable liquids or flammable waste, such as wipes or cleaning  

 

rags. 

 

DO NOT

 fit a bulb larger than 100 watts.

  When not in use switch off the lamp and remove plug from power supply.

 

Remember that the wire guard will be hot during 

and after

 use.

 

Use gripper on secure, non-flammable supports only.

Yellow & Green 

Earth wire 

Original Language Version

ML100/GP     Issue: 2 - 19/10/09