1.  sAfEtY instrUCtions

IMPORTANT:

 

PLEAsE rEAd thEsE instrUCtions CArEfULLY. notE thE sAfE oPErAtionAL rEQUirEMEnts, WArninGs And CAUtions. UsE 

thE  ProdUCt  CorrECtLY  And  With  CArE  for  thE  PUrPosE  for  WhiCh  it  is  intEndEd.  fAiLUrE  to  do  so  MAY  CAUsE 

dAMAGE And/or PErsonAL inJUrY And WiLL inVALidAtE thE WArrAntY. PLEAsE KEEP instrUCtions sAfE for fUtUrE UsE.

1.1. 

ELECtriCAL sAfEtY

  

WArninG!

 It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other con-

nectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A 

residual current circuit Breaker (rccB) should be incorporated in the main distribution board. We also recommend that a residual current 

device (rcd) is used. It is particularly important to use an rcd with portable products that are plugged into a supply which is not protected by 

an rccB. If in any doubt consult a qualified electrician. You may obtain a residual current device by contacting your sealey dealer. 

You must

 also read and understand the following instructions concerning electrical safety.

1.1.1.  the 

Electricity at Work Act 1989 

requires all portable electrical appliances, if used on business premises, to be tested by a qualified  

 

electrician, using a Portable Appliance tester (PAt), at least once a year.

1.1.2.  the 

health & safety at Work Act 1974 

makes owners of electrical appliances responsible for the safe condition of those appliances  

 

and the safety of the appliance operators. 

if in any doubt about electrical safety, contact a qualified electrician.

1.1.3.  ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. see 1.1.1. and 1.1.2. and  

use a Portable Appliance tester.

1.1.4.  ensure that cables are always protected against short circuit and overload.

1.1.5.  regularly inspect power supply cables and plugs for wear or damage and check all

 

connections to ensure that none is loose.

1.1.6. 

important:

 ensure that the voltage marked on the appliance matches the power supply 

 

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7. 

do not

 pull or carry the appliance by the power cable.

1.1.8. 

do not 

pull the plug from the socket by the cable.

1.1.9. 

do not

 use worn or damaged cables, plugs or connectors. Immediately have any faulty 

 

item repaired or replaced by a qualified electrician. When an AstA/Bs approved uK 

 

3 pin plug is damaged, cut the cable just above the plug and 

dispose of the plug safely. 

 

fit a new plug according to the following instructions (uK only).

 

a)  Connect the GrEEn/YELLoW earth wire to the earth terminal ‘E’.

 

b)  Connect the BroWn live wire to the live terminal ‘L’.

 

c)  Connect the BLUE neutral wire to the neutral terminal ‘n’.

 

d)  After wiring, check that there are no bare wires, that all wires have been correctly  

 

connected, that the cable outer insulation extends beyond the cable restraint and that the restraint is tight.

 

double insulated products, which are always marked with this symbol      , are fitted with live (brown) and neutral (blue) wires only.   

 

to rewire, connect the wires as indicated above - 

do not

 connect either wire to the earth terminal.

1.1.10.  If an extension reel is used it should be fully unwound before connection. A reel with an rcd fitted is preferred since any appliance  

 

plugged into it will be protected. the cable core section is important and should be at least 2.5m².  

1.2.   GEnErAL sAfEtY instrUCtions

  

WARNING! If a fuse blows, identify and rectify the fault, ensure it is replaced with a fuse of identical type and rating.

  

WARNING! Ensure there is nobody in front of the lamp when it is switched on.

 

disconnect the panel dryer from the power supply before servicing, changing accessories, or  

  performing any maintenance.

  ensure that the panel dryer is in good condition before use. If in any doubt do not use the unit  

  and contact an electrician.

  familiarise yourself with the application and limitations of the panel dryer.     

  check that lamp guards are in place, undamaged and firmly attached. 

  Keep tools and other items away from the panel dryer when it is in use.

  Keep the work area clean and clear of unnecessary items.

 

remember that the lamp panel will get hot, allow to cool after use.

 

 

maintain the panel dryer in good condition. use authorised agent for servicing. 

 

Keep the dryer clean, but 

do not

 use solvents.

 

use only genuine parts and accessories. 

Unauthorised parts and accessories may be  

  dangerous and will invalidate your warranty.

  do not use this product to perform a task for which it has not been designed.

 

do not use the panel dryer outdoors, or in damp, or wet locations, and do not operate within  

  the vicinity of flammable liquids, gases or solids.

  

WARNING! Never use in explosive situations.

  Keep children and unauthorised persons away from the work area.

  When not in use, store the panel dryer carefully in a safe, dry, childproof location.

fUsE rAtinG

 

13 AMP

2.  introdUCtion

Blue 

Neutral 

Wire

Yellow & Green 

Earth Wire 

Cable 

Restraint

Brown

Live 

Wire

the Ir3000 has three 1kW high output short wave lamps, fitted into three individual cassettes. lamps emit short wave infrared heat ideal for 

optimizing drying of water-borne paints. this flexible system allows each cassette to be adjusted and locked into position around the contours of 

the vehicle body, ensuring maximum area coverage.

Height adjustment is made using the high performance locking gas strut, offering a near weightless movement to the cassette support arm.

Original Language Version

Ir3000    Issue: 2 - 14/04/10