devices that require a large starting current. this is not a malfunction.
4.3.4.
Ac pilot light (green)
The AC pilot light fig.3.(2) comes on when the engine starts and produces power.
4.4.
Dc protector
4.4.1.
The DC protector turns to “OFF” fig.4.(2) automatically when electric device being
connected to the generator is operating at a higher current than the max stated in
specifications.
4.4.2.
to turn the power on press the button to the “on” (1) position.
n.B. reduce the load before restarting.
4.5.
Economy control switch (ECS) fig.5
4.5.1.
“on” (1)
When the ecs switch is turned to “on” the economy control unit controls the engine speed according to the connected load. the
results are better fuel consumption and less noise.
4.5.2.
“off” (2)
When the ecs switch is turned to “off” the engine runs at the rated speed (3600r/min) regardless of whether a load is connected or
not.
4.5.3.
the ecs must be turned to “off” when using electric devices that require a larger starting current.
4.6.
Earth terminal fig.4
4.6.1.
Earth terminal fig.5.(1) connects the earth line to prevent electric shock.
n.B if the device is earthed the generator must be earthed.
4.7.
fueL
4.7.1.
Do not
overfill the fuel tank, otherwise it may
overflow when the fuel warms up and expands.
4.7.2.
After filling ensure tank cap is tightened securely.
4.7.3.
Wipe off any fuel that has been spilled.
4.7.4.
use only unleaded petrol.
4.7.5.
Remove the fuel tank cap fig.6.
4.7.6.
Pour in fuel up to the red line fig.7. (1)
4.7.7.
Fuel level fig.8. (2)
4.8.
engine oil
n.B. the generator has been transported without engine oil.
Do not
start the
engine until filled with sufficient engine oil.
4.8.1.
Place the generator on a level surface.
4.8.2.
remove the oil gauge.
4.8.3.
Fill the generator with the amount of engine oil specified.
4.8.4.
Replace oil gauge fig.9.
4.8.5.
Recommended engine oil SAE SJ 15W-40.
4.8.6.
Engine oil capacity 0.45L.
4.9.
standard atmospheric conditions
Ambient temperature 25
o
c
Barometric pressure 100kPa
relative humidity 30%
the output of the generator will vary dependant on the deviation from the standard conditions.
fig.4
fig.5
fig.6
fig.7
fig.8
fig.9