background image

BENCH DRILLS

MODEL NO’S:  

GDM50B.V2, GDM92B, 

GDM120B.V2, GDM150B.V2, GDM180B.V2,   

   

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAFETY

1. 

ELECTRICAL SAFETY

 

‰

  

WARNING! 

It is the user’s responsibility to check the following:

 

Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and all    

 

electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical    

 

products. You may obtain an RCD by contacting your local Sealey dealer. 

 

if the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable Appliance  

 

Test) tested.

 

Electrical safety information:

 it is important that the following information is read and understood.

1.2. 

Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. 

1.3.

 

Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

1.4. Important

: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the correct  

 

fuse - see fuse rating in these instructions.

 

8

DO NOT

 pull or carry the appliance by the power cable.

 

8

DO NOT

 pull the plug from the socket by the cable. 

 

8

DO NOT

 use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or replaced immediately by a 

qualified electrician.

1.5.

 

This product is fitted with a BS1363/A 13 Amp 3 pin plug. 

          If the cable or plug is damaged during use, switch the electricity supply and remove from use. 

         Ensure that repairs are carried out by a qualified electrician.

       

Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.

 

A) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

B) Connect the BROWN live wire to the live terminal ‘L’.

 

C) Connect the BLUE neutral wire to the neutral terminal ‘N’.

         Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. 

         Sealey recommend that repairs are carried out by a qualified electrician.

1.2. 

GENERAL SAFETY

 

‰

 

WARNING! Disconnect drill from mains power before changing accessories, servicing or  

  

performing any maintenance.

 

‰

 

WARNING!

 

Keep all guards and holding screws in place, tight and in good working order. Check  

 

regularly for damaged parts. 

 

9

 A guard or any other part that is damaged should be replaced, before the tool is used, to ensure 

            that it operates properly and perform its intended function. The safety guard is a mandatory fitting where drill is used in premises covered  

            by the Health & Safety at Work Act. 

 

 

9

 Check alignment of moving parts and check for possible broken parts. 

 

9

 Replace or repair damaged parts. 

Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

 

9

 Ensure the set screws of the head frame are screwed tight before using the drill. 

 

9

 Secure the drill to the workbench or floor.

 

9

 Drill is designed for use with drill bits only. 

 

9

 Ensure the chuck is securely fastened to the spindle.

 

9

 Remove adjusting keys, chuck key and wrenches from the machine and working area before switching on.

 

9

 Use clamps or a vice (not included; available from your Sealey stockist) to secure the workpiece. 

DO NOT

 attempt to hold the  

 

workpiece by hand. 

 

9

 Refer to speed chart for recommended drilling speeds.

 

‰

 

WARNING! Always wear approved eye or face protection when operating this drill. Use face or dust mask if dust is generated.

 

9

 Keep drill bits clean and sharp for best and safest performance. Follow the instructions for lubrication and changing accessories.

 

9

 Remove ill fitting clothing. Remove ties, watches, rings and other loose jewellery and contain long hair.

 

9

 Locate the drill in a suitable work area, keep area clean and tidy and free from unrelated materials. Ensure there is adequate lighting.

 

9

 Exclude children and non-essential persons from the work area.

 

9

Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.

 

9

Avoid unintentional starting.

GDM Series 50B.V2, 92B, 120B.V2, 150B.V2, 180B.V2  ....Issue1       22/06/21

Original Language Version

© Jack Sealey Limited

Refer to 

instructions

 Wear eye 

protection

 Wear ear 

protection

 Wear a mask

Recommended fuse 

rating:

 

13A

 Indoor use only

Summary of Contents for GDM50B.V2

Page 1: ...ELLOW earth wire to the earth terminal E B Connect the BROWN live wire to the live terminal L C Connect the BLUE neutral wire to the neutral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 2 GENERAL SAFETY WARNING Disconnect drill from mains power before chang...

Page 2: ... to Column 127mm 127mm 165mm Spindle Travel 60mm 60mm 80mm Number of Speeds 5 12 16 Speed Range 460 2890rpm 210 2580rpm 210 3340rpm Maximum Distance Spindle to Table 300mm 390mm 410mm Maximum Distance Spindle to Base 450mm 540mm 600mm Working Table Surface Size Ø248mm Ø248 Ø310 Working Base Surface Size 160 x 180mm 160 x 180mm 210 x 190mm Overall Base Size 345 x 215mm 345 x 215mm 520 x 320mm Colum...

Page 3: ...into chuck jaws to 1 25mm deep avoid inserting small bits too far and centre bit in chuck before tightening 6 2 ADJUSTING THE TABLE 6 2 1 To adjust table up or down loosen the clamp bolt fig 2 B then turn the bracket handle fig 2 A 6 2 2 To adjust table tilt loosen the work table bolt fig 2 C remove locking pin below bolt and adjust to the desired angle using the angle scale then retighten When re...

Page 4: ...rill wobble 1 Chuck is loose 2 Bearing or spindle shaft is worn 3 Chuck is worn 4 Drill fitted incorrectly or faulty 1 Refit the chuck see 5 1 11 2 Replace worn part 3 Replace the chuck 4 Fit correctly or change drill Drill binds in the workpiece 1 Feed pressure is wrong 2 Belt is loose 3 Drill bit is loose 4 Speed is too fast 1 Apply less pressure 2 Adjust tension 3 Tighten the chuck jaws with th...

Page 5: ...e with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authority for recycling information Original Language Version Jack Sealey Limited GDM Series 50B V2 92B 120B V2 150B V2 180B V2 Issue1 22 06 21 Note It is our policy to continually improve product...

Reviews: