Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

 

PlEasE rEad THEsE iNsTrUCTiONs CarEFUllY. NOTE THE saFE OPEraTiONal rEQUirEMENTs, WarNiNGs aNd 

CaUTiONs. UsE THis PrOdUCT COrrECTlY aNd WiTH CarE FOr THE PUrPOsE FOr WHiCH iT is iNTENdEd. FailUrE TO dO sO MaY 

CaUsE daMaGE Or PErsONal iNJUrY aNd Will iNValidaTE THE WarraNTY. PlEasE KEEP iNsTrUCTiONs saFE FOr FUTUrE UsE.

  1.  saFETY iNsTrUCTiONs

1.1. 

ElECTriCal saFETY. 

WarNiNG! it is the user’s responsibility to read, understand and comply with the following:

You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs and 

all electrical connections for wear or damage. You must ensure the risk of electric shock is minimised by the installation of appropriate safety 

devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board. We also recommend that an RCD

(Residual Current Device) is used with all electrical products. It is particularly important to use an RCD with portable products that are plugged 

into an electrical supply not protected by an RCCB. If in doubt consult a professional electrician. You may obtain a Residual Current Device by 

contacting your Sealey dealer. 

You must

 also read and understand the following instructions concerning electrical safety.

1.1.1.  The 

Electricity At Work Act 1989

 requires all portable electrical appliances, if used on business premises, to be tested by 

 

a qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2.  The 

Health & Safety at Work Act 1974

 makes owners of electrical appliances responsible for the safe condition of those appliances, 

 

and the safety of appliance operators. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3.  Ensure the insulation on all cables and the product itself is safe before connecting to the mains power supply. 

 

See 1.1.1. & 1.1.2. above and use a Portable Appliance Tester (PAT).

1.1.4.  Ensure that cables are always protected against short circuit and overload.

1.1.5.  Regularly inspect power supply leads and plugs for wear or damage and connections to ensure that none is loose. 

1.1.6. 

Important: 

Ensure the voltage marked on the product is the same as the electrical power    

 

supply to be used, and check that plugs are fitted with the correct capacity fuse. A 13 amp plug  

 

may require a fuse smaller than 13 amps for certain products (

subject to 1.1.10. below).

 

1.1.7.  DO NOT pull or carry the powered appliance by its power supply lead. Products such as

 

welders must not be pulled or carried by their output cables.

1.1.8.  DO NOT pull power plugs from sockets by the power cable.

1.1.9.  DO NOT use worn or damage leads, plugs or connections. Immediately replace or have  

 

 

repaired by a qualified electrician. Where a U.K. 3 pin plug with ASTA/BS approval is fitted, in  

 

case of damage, cut off and fit a new plug according to the following instructions (discard old  

 

plug safely).

 

(UK only - see diagram at right). 

Ensure the unit is correctly earthed via a three-pin plug. 

 

a)   Connect the gREEN/YEllOW earth wire to the earth terminal ‘E’.

 

b)  Connect the bROWN live wire to the live terminal ‘l’.

 

c)   Connect the bluE neutral wire to the neutral terminal ‘N’.

 

 

After wiring, check there are no bare wires, that all wires have been correctly  

 

 

 

connected, that the cable outer insulation extends past the cable restraint and that the cable restraint is tight.

 

 

Double insulated products are often fitted with live (BROWN) and neutral (BLUE) wires only. Double insulated products are always    

 

marked with this symbol      . 

To re-wire, connect the brown & blue wires as indicated above.

 

DO NOT connect the brown or blue  

 

wires to the earth terminal.

1.1.10. 

NOTE: 

If this product requires more than a 13 amp electrical supply, then 

NO

 plug is fitted. 

You must

  therefore contact a qualified    

 

electrician to ensure a 30 amp fused supply is available. We recommend you discuss the installation of a industrial round pin plug &    

 

socket with your electrician. 

1.1.11. 

Cable extension reels

. When a cable extension reel is used it should be fully unwound before connection. A cable reel with an RCD

 

fitted is recommended since any product which is plugged into the cable reel will be protected. The section of the cores in the cable

 

is important and should be at least 1.5mm², but to be absolutely sure that the capacity of the cable reel is suitable for this product and  

 

for others that may be used in the other output sockets, the use of 2.5mm² section is recommended .

1.2 

GENEral saFETY

p

 

WarNiNG! disconnect drill from mains power before changing accessories, servicing or performing any  

  maintenance.

3

 

Maintain the

 

drill in good condition (use an authorised service agent).

p

 

WarNiNG!

 

Keep all guards and holding screws in place, tight and in good working order. Check  

 

  regularly for damaged parts. a guard or any other part that is damaged should be checked, before the  

  tool is used, to ensure that it will operate properly and perform its intended function. The safety guard is  

  a mandatory fitting where drill is used in premises covered by the Health & safety at Work act. 

 

3

  Check alignment of moving parts and check for possible broken parts. 

3

  Replace or repair damaged parts. 

Use recommended parts only. Non-authorised parts may be dangerous and  

  will invalidate the warranty.

3

  Ensure the set screws of the head frame are screwed tight before using the drill. 

3

  Secure drill to the floor to avoid the machine tipping, sliding or walking. Drill is designed for use with drill bits only.

3

  Ensure the chuck is securely fastened to the spindle.

3

  Remove adjusting keys and wrenches from the machine and working area before switching on.

3

  Use clamps or a vice (not included) to secure the workpiece. Available from your Sealey dealer. DO NOT secure  

  the workpiece by hand. 

3

  Refer to speed chart for recommended drilling speeds.

p

 

WarNiNG! always wear approved eye or face protection when operating this drill. Use a face or dust  

  mask if dust is generated. 

3

  Others in the workplace should keep a safe distance from the drill, especially when it is in operation.

3

  Keep the work area as childproof as possible by using padlocks and master switches.

rEPlaCEMENT FUsEs MUsT 

BE OF THE saME TYPE aNd 

raTiNG as THE OriGiNal

blue 

Neutral 

wire

Yellow & green 

Earth wire 

Cable 

restraint

brown

live 

wire

Original Language Version

GDM120B, GDM160F    Issue: 4 - 24/02/12

Summary of Contents for GDM120B

Page 1: ...ee diagram at right Ensure the unit is correctly earthed via a three pin plug a Connect the green yellow earth wire to the earth terminal E b Connect the brown live wire to the live terminal L c Connect the blue neutral wire to the neutral terminal N After wiring check there are no bare wires that all wires have been correctly connected that the cable outer insulation extends past the cable restra...

Page 2: ...ble speed drills are suitable for light industrial agricultural and woodworking applications The drills are fitted with flip up safety guards and No Volt Release switches which prevent accidental restart after a mains power interruption A rack and pinion feed shaft with preset depth control for repetitive work is also included Both have Morse taper spindles to accept taper shank bits Mortice attac...

Page 3: ...n locking screw 6 6 3 When ready to drill simply pull the feed handle The drill will stop at the set depth 6 OPERATING INSTRUCTIONS Note Figures are illustrative and may differ in detail from your drill 5 1 Assembly 5 1 1 Place the column assembly on the base align holes and secure with the bolts and washers provided 5 1 2 Install table bracket onto column together with rack fig 1 engaging gear in...

Page 4: ...9 troubleshooting 8 1 Clean the tool after each use A coat of automobile type wax applied to the table and column will help to keep the surfaces clean 8 2 Blow out any dust that may have accumulated in the motor 8 3 Periodically lubricate the table elevation rack gear worm mechanism 8 MAINTENANCE 7 DRILL speeds Drill Speed rpm Drill Dia mm Steel Cast Iron Iron Alum Copper 3 1820 2580 2580 2580 4 1...

Reviews: