InstructIons for:

laser Wheel alignment gauge

MoDEL no:

 

ga50.V3

thank  you  for  purchasing  a  sealey  product.  Manufactured  to  a  high  standard  this  product  will,  if  used  according  to  these  instructions 

and properly maintained, give you years of trouble free performance.

1.  saFetY instruCtiOns

IMPORTANT:

 

Please reaD these instruCtiOns CareFullY. nOte the saFe OPeratiOnal reQuirements, Warnings & CautiOns. 

use  the  PrODuCt  COrreCtlY  anD  With  Care  FOr  the  PurPOse  FOr  WhiCh  it  is  intenDeD.  Failure  tO  DO  sO  maY  Cause 

Damage anD/Or  PersOnal  inJurY anD  Will  inValiDate  the  WarrantY.  Please  KeeP  instruCtiOns  saFe  FOr  Future  use.

1.1  general saFetY

 

Warning!

 

Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this equipment.

 

Maintain the

 

gauge in good condition (use an authorised service agent).

 

replace or repair damaged parts. 

Use genuine parts only. Non-authorised parts may be dangerous and will invalidate the warranty.

 

Locate gauge in a suitable working area, keep area clean and tidy and free from unrelated materials. 

 

Warning! 

use gauge on level and solid ground.

 

Keep the gauge clean to ensure accurate performance.

 

DO nOt

 use outside in damp or wet weather conditions. 

 

DO nOt

 allow untrained persons to operate the gauge.

 

DO nOt

 leave the gauge unattended.

 

Warning! 

When setting front end alignment on commercial vehicles never make adjustments to drop arms or interconnecting links. 

 

Doing so could result in serious tyre, wheel and steering problems.

 

Any alignment changes deemed necessary as a result of using this equipment must be made strictly in accordance with the vehicle  

 

 

manufacturer’s recommendations.

2.  intrODuCtiOn & sPeCiFiCatiOn

3.  assemblY & CalibratiOn

updated version of optical system uses low radiation laser beam to indicate toe-in or toe-out. single leg configuration and reversible contact 

probes allows on-ramp use. Works on practically all cars and light commercials with rim diameters from 200 to 600mm. Powered by 2 x AA 

cells and includes operating instructions.

Wheel rim capacities:

  . . . . . . . . . . . . . . . . . . 8” - 24” rim diameter 

  measuring range:

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +/- 2deg

laser beam height:

  . . . . . . . . . . . . . . . . . . . . . . . . . . under 50mm  

laser:

 . . . . . . . . . . . . . class II, 1.0 milliwatt, Wavelength 620 - 680nm

battery:

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 x type AA 1.4 volts 

estimated battery life:

. . . . . . . . . . . 6 - 12 months, dependant on use

switch:

  . . . . . . . . . . . . . . . . . . . . . . . Momentary operator pressure 

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . (Power off when not depressed)

 

Warning!

 

Do not switch on the laser unit when detached from the main gauge. When correctly assembled to the gauge the laser  

 

 

should only be switched on when the two sides of the gauge are correctly positioned in relation to each other either for calibration  

 

 

purposes or for wheel alignment use.

3.1  assemblY.

 Your gauge has been supplied in flat pack form for quick and easy assembly.

3.1.1 take each ready assembled side frame in turn and slide the leg away from the alignment peg in the main tube and turn the leg through  

 

90° so that it faces in the same direction as the indents on the main arms. slide the leg back onto the alignment peg and insert and    

 

tighten a thumbscrew.

3.1.2 Place the two frames opposite each other with each extended bar portion positioned to the right hand side. the frame nearest to you is  

 

the one to which the laser unit should be attached. 

3.1.3 Place the laser unit onto the tube and slide it to the left until it stops against the end of the tube. Insert and tighten a thumbscrew on the  

 

back of the unit to secure it to the main bar. the thumb screw will be used later to adjust the tilt of the laser unit

3.1.4 slip the mirror unit onto the main bar of the other frame and insert and tighten a thumbscrew to secure it. (use the built in spirit level to   

 

ensure that the mirror is vertical).

3.1.5 Attach a contact bar to each of the upright arms. firstly loosen the thumb screw on the contact bar holder and place it through the  

 

 

upright arm. slide the square portion of a contact bar through an indent on the upright, through the holder, then through the other indent.  

 

tighten the thumbscrew to secure.

3.1.6 Each contact bar may be fitted either to the left or the right of its respective support arm and may be reversed to use the long or short    

 

contact arm. this is to allow the gauge to handle all tyres on 8” to 24” diameter rims and to allow close contact when required e.g. when  

 

in use on a vehicle lift.

3.2  CalibratiOn. 

the gauge will be calibrated each time it is used as part of the process of checking wheel alignment. calibration will be  

 

done with the two halves of the gauge facing each other with the contact bars touching. for further details refer to the operating  

 

 

instructions which follow.

1.2  laser saFetY

   

GA50.V3 utilises a class II laser that emits low levels of visible radiation (i.e. wavelengths between 400 and 700 nanometres) which are  

   

safe for the skin but not inherently safe for the eyes. the class II emission limit is set at the maximum level for which eye protection is  

   

normally afforded by natural aversion responses to bright light. Accidental eye exposure is therefore normally safe, although the natural  

   

aversion response can be overridden by deliberately staring into the beam, and can also be influenced by the use of alcohol or drugs.

  

 

Warning!

 

Do not look or stare into the laser beam as permanent eye damage could result. 

  

 

DO nOt

 direct the laser beam at any person’s (or animal’s) eyes as eye damage could result. If the beam is obstructed by 

   

a person during use, release the contact switch immediately.

  

 

DO nOt

 use the equipment while under the influence of alcohol, drugs or whilst on medication.

  

  Be aware that reflections of the laser beam from mirrors or other shiny surfaces can be as hazardous as direct eye exposure. 

GA50.V3    Issue no.1 - 04/09/09