background image

InstructIons for:

battery chargerS

IMPORTANT:

 

PLeaSe reaD theSe INStrUctIONS careFULLy. NOte the SaFe OPeratIONaL reQUIreMeNtS, WarNINgS aND caUtIONS. USe thIS 

PrODUct cOrrectLy aND WIth care FOr the PUrPOSe FOr WhIch It IS INteNDeD. FaILUre tO DO SO May caUSe DaMage aND/Or PerSONaL 

INJUry aND WILL INVaLIDate the WarraNty. PLeaSe retaIN theSe INStrUctIONS FOr FUtUre USe.

thank you for purchasing a sealey product. Manufactured to a high standard this product will give you years of trouble free performance if these instructions are carefully followed and the 

product is correctly maintained.

  1.  SaFety INStrUctIONS

MoDEL no:

 charge6, charge8, charge10, charge15

1.1. 

eLectrIcaL SaFety

  

WarNINg!

 It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other 

connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A 

residual current circuit Breaker (rccB) should be incorporated in the main distribution board. We also recommend that a residual current 

Device (rcD) is used. It is particularly important to use an rcD with portable products that are plugged into a supply which is not protected 

by an rccB. If in any doubt consult a qualified electrician. You may obtain a residual current Device by contacting your sealey dealer. 

you must

 also read and understand the following instructions concerning electrical safety.

1.1.1.  the 

electricity at Work act 1989 

requires that all portable electrical appliances, if used on business premises, are tested by a  

 

 

qualified electrician, using a Portable Appliance tester (PAt), at least once a year.

1.1.2.  the 

health & Safety at Work act 1974 

makes owners of electrical appliances responsible for the safe condition of those appliances  

 

and the safety of the appliance operators. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3.  Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. see 1.1.1. and 1.1.2.    

 

and use a Portable Appliance tester.

1.1.4.  Ensure that cables are always protected against short circuit and overload.

1.1.5.  regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none is loose.

1.1.6. 

Important:

 Ensure that the voltage marked on the appliance matches the power supply 

 

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7. 

DO NOt

 pull or carry the appliance by the power cable.

1.1.8. 

DO NOt 

pull the plug from the socket by the cable.

1.1.9. 

DO NOt

 use worn or damaged cables, plugs or connectors. Immediately have any faulty 

 

item repaired or replaced by a qualified electrician. When a Bs 1363/A uK 3 pin plug is  

 

 

damaged, cut the cable just above the plug and 

dispose of the plug safely. 

 

fit a new plug according to the following instructions (uK only).

 

a)  connect the brOWN live wire to the live terminal ‘L’.

 

b)  connect the bLUe neutral wire to the neutral terminal ‘N’.

 

c)  after wiring, check that there are no bare wires, that all wires have been correctly    

 

connected, that the cable outer insulation extends beyond the cable restraint and  

 

 

that the restraint is tight.

 

Double insulated products, which are always marked with this symbol      , are fitted with live  

 

(brown) and neutral (blue) wires only. to rewire, connect the wires as indicated above - 

DO NOt

 connect either wire to the earth  

 

 

terminal.

1.1.10.  If an extension reel is used it should be fully unwound before connection. A reel with an rcD fitted is preferred since any appliance    

 

plugged into it will be protected. the cable core section is important and should be at least 1.5mm², but to be absolutely sure that the  

 

capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use   

 

of 2.5mm² section cable.

1.2. 

geNeraL SaFety

 

WARNING!

 

Disconnect the charger from the mains power before servicing or performing any maintenance.

 

Disconnect the charger from the mains power before connecting to, or disconnecting from the battery.

 

Maintain the

 

charger in good condition (use an authorised service agent only).

 

WARNING!

 

the charger has components such as switches and relays which may cause sparks or arcs. When using the charger in a  

 

  garage or workshop, make sure that it is in a safe location.

 

Keep the charger clean for best and safest performance.

 

WARNING!

 

Ensure that there are no sources of  ignition in or near the work area i.e. naked flames, cigarettes, heaters etc. as the charging  

  process produces explosive gases.

 

WARNING!

 Ensure that the work area is well ventilated as the gases produced are explosive.

 

Locate the charger in a suitable work area and keep the area clean and tidy and free from unrelated materials. Ensure that there is  

 

  adequate lighting.

 

Wear approved safety eye protection (standard spectacles are not adequate).

 

remove ill fitting clothing. remove ties, watches, rings and other loose jewellery and contain long hair.

 

read vehicle manufacturer’s manual to check for any specific battery charging information.

 

Disconnect the battery from the vehicle and move it to a safe, dry, level area for charging. If the battery cannot be removed from the  

 

  vehicle refer to manufacturer’s manual.

 

check that the electrolyte level in the battery is above the plates. If not, add distilled water to cover them by 5 - 10mm. Do not touch the  

  battery fluid as it is corrosive.

 

clean the charger clamps and battery terminals, before connecting the charger, to ensure good contact.

 

Ensure that the correct polarity clamp  is attached to the correct terminal of the battery. PosItIVE is indicated by + and red and  

 

  nEGAtIVE is indicated by - and black. If there are no identifiable symbols, the nEGAtIVE terminal is the one which is connected directly   

  to the vehicle body.

 

remove the battery electrolyte cover or caps to allow the gases produced by charging to escape. 

 

Keep children and unauthorised persons away from the work area.

 

Do not attempt to charge a non-rechargeable battery.

FUSe ratINg

 

3 aMP

Blue 

Neutral 

Wire

Cable 

Restraint

Brown

Live 

Wire

Original Language Version

cHArGE6, cHArGE8, cHArGE10, cHArGE15    Issue: 2 - 05/03/10

Summary of Contents for CHARGE6

Page 1: ...t the BROWN live wire to the live terminal L b Connect the BLUE neutral wire to the neutral terminal N c After wiring check that there are no bare wires that all wires have been correctly connected that the cable outer insulation extends beyond the cable restraint and that the restraint is tight Double insulated products which are always marked with this symbol are fitted with live brown and neutr...

Page 2: ...battery to the vehicle secure according the manufacturer s instructions and re connect the power leads Check to ensure that all tools are removed before closing the bonnet or boot 3 4 WARNING LOW MAINTENANCE or SEALED NO MAINTENANCE BATTERY CHARGING 3 4 1 When charging a low or no maintenance battery take very special care Continually monitor the voltage across the battery terminals and when it re...

Page 3: ...ig 4A 4 2 Two 12 volt batteries may be charged in series using the 24 volt output of Charge15 as shown in fig 4B This is only recommended if both batteries are of similar capacity and are in a similar state of discharge fig 4 NOTE It is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice IMPORTANT No liab...

Page 4: ...amp 9 120 712624 Work Clamp 10 120 802256 Kit 10 Fuses 15A 11 120 990460 Kit Ammeter CHARGE 8 CHARGE 10 CHARGE 15 CHARGE 6 ITEM PART NO DESCRIPTION 2 120 122190 Fuse T500mA 4 120 164173 Transformer 5 120 322432 Cap Kit 6 120 712623 Positive Clamp 7 120 712624 Work Clamp 8 120 802319 Kit 10 Fuses 4A NOTE It is our policy to continually improve products and as such we reserve the right to alter data...

Reviews: