Installation and Operations Manual

 

 

 
 
 
 
 
 
 
 
   
 
 
 
 
 
 

 

Seaira Global, LLC 

 

 

14021 NC Highway 50 

Surf City, NC 28445

(910) 660-0962

WatchDog NXT120

Summary of Contents for WatchDog NXT120

Page 1: ...Installation and Operations Manual Seaira Global LLC 14021 NC Highway 50 Surf City NC 28445 910 660 0962 WatchDog NXT120...

Page 2: ...ow it Works Installation Requirements Installation Key Functions Indicator Lights Remote Control Operating Instructions Unit Diagram Maintenance Dehumidifier Storage Ducted Applications Troubleshootin...

Page 3: ...ted with at least 15 amp capacity The use of any other type of wiring will void your warranty Install dehumidifier according to all applicable local state and national codes Be sure to follow your GFC...

Page 4: ...il which is cooler than the dew point of air This means moisture will condense out of the air The air is then reheated through the condenser coil and distributed back into the room Installation Requir...

Page 5: ...into a 3 4 elbow 3 Attach PVC elbow to a 3 4 OD length of PVC to drain Keep the length of PVC as short as possible 4 Insert the open end of dehumidifier drain tube into 6 piece of PVC so that it does...

Page 6: ...mally closed on the external device Note that you may need to unplug the unit to reset the error code To set the unit to run continuously regardless of humidity simply use the down arrow key to set th...

Page 7: ...ted If the humidity is above the setpoint the light will be solid green and the machine will operate If the humidity is below the setpoint the unit will be in standby mode and the light will be flashi...

Page 8: ...Button Press the on off button and the machine will start running Press the button again to turn the machine off 2 Up Button Down Button Use the up and down arrows to adjust the humidity level 3 Mode...

Page 9: ...difier will stop Note that the fan will continue to operate for 1 minute after the unit has shut off DO NOT DISCONNECT THE POWER CORD TO FORCE THE UNIT TO STOP 4 Water Drainage During normal operation...

Page 10: ...re doing any maintenance Cleaning the Machine Body Use a soft damp cloth to clean the exterior of unit Do not use any soap or solvents Coil Maintenance Once per year clean the coils with an approved c...

Page 11: ...the control board cover Mix a 16 ounce solution of bleach 1 oz bleach 15 oz water OR vinegar 4 oz white vinegar 12 oz water Remove filter s so you have access to the drain tray Disconnect power to deh...

Page 12: ...ifier allows the unit to be in one room while conditioning an adjacent room Both the inlet return grille and the supply grille are designed for 10 flex ducting Ducting Installation Notes Be sure to se...

Page 13: ...12 Troubleshooting...

Page 14: ...13 Spare Parts...

Page 15: ...the day the shipment left the warehouse Please be sure to record serial and date of installation in the spaces provided on page 2 of the manual You will need this information to receive an RA number 2...

Page 16: ...D LIABILITIES SET FORTH ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED IN LAW OR IN FACT INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE SEAIRA GLOBAL S TO...

Reviews: