Seagate ST1600FM0003 Product Manual Download Page 1

100773817, Rev. A

September 2015

1200.2 SSD

SAS Product Manual

High Endurance models

Standard drives

ST400FM0323
ST200FM0133

Self-Encrypting drives

ST400FM0333
ST200FM0143

Scalable Endurance

models

Standard drives

ST3840FM0043
ST1920FM0043

Self-Encrypting drives

ST3840FM0053
ST1920FM0053

Mainstream Endurance models

Standard drives

ST3200FM0023
ST1600FM0003

ST800FM0173
ST400FM0233

Self-Encrypting drives

ST3200FM0033
ST1600FM0013

ST800FM0183
ST400FM0243

SED FIPS 140-2 Models 

(Review Pending)

ST3200FM0043
ST1600FM0023

ST800FM0213
ST400FM0293

Light Endurance models

Standard drives

ST3840FM0003
ST3200FM0063
ST1920FM0003
ST1600FM0073

ST960FM0003
ST800FM0233
ST480FM0003
ST400FM0303

Self-Encrypting drives

ST3840FM0023
ST3200FM0073
ST1920FM0023
ST1600FM0083

ST960FM0013
ST800FM0243
ST480FM0013
ST400FM0343

Summary of Contents for ST1600FM0003

Page 1: ...durance models Standard drives ST3200FM0023 ST1600FM0003 ST800FM0173 ST400FM0233 Self Encrypting drives ST3200FM0033 ST1600FM0013 ST800FM0183 ST400FM0243 SED FIPS 140 2 Models Review Pending ST3200FM0043 ST1600FM0023 ST800FM0213 ST400FM0293 Light Endurance models Standard drives ST3840FM0003 ST3200FM0063 ST1920FM0003 ST1600FM0073 ST960FM0003 ST800FM0233 ST480FM0003 ST400FM0303 Self Encrypting driv...

Page 2: ...g to drive capacity one gigabyte or GB equals one billion bytes and one terabyte or TB equals one trillion bytes Your computer s operating system may use a different standard of measurement and report a lower capacity In addition some of the listed capacity is used for formatting and other functions and thus will not be available for data storage Actual quantities will vary based on various factor...

Page 3: ...lock Provisioning 14 3 8 2 Thin Provisioning capabilities 14 3 8 3 UNMAP 14 3 8 4 FORMAT UNIT command 14 3 8 5 Protection Information PI and Security SED 15 4 0 Performance characteristics 16 4 1 Internal drive characteristics 16 4 2 Performance characteristics 16 4 2 1 Response time 16 4 2 2 FORMAT UNIT command execution time for 512 byte LBA s minutes 17 4 2 3 Performance 18 4 3 Start stop time ...

Page 4: ... cleanliness 46 6 3 6 Corrosive environment 46 6 3 7 Electromagnetic susceptibility 46 6 4 Mechanical specifications 47 7 0 About FIPS 49 8 0 About self encrypting drives 50 8 1 Data encryption 50 8 2 Controlled access 50 8 2 1 Admin SP 50 8 2 2 Locking SP 50 8 2 3 Default password 50 8 3 Random number generator RNG 50 8 4 Drive locking 51 8 5 Data bands 51 8 6 Cryptographic erase 51 8 7 Authentic...

Page 5: ...11 3 SCSI commands supported 58 11 3 1 INQUIRY data 63 11 3 2 MODE SENSE data 64 11 4 Miscellaneous operating features and conditions 65 11 4 1 SAS physical interface 65 11 4 2 Physical characteristics 68 11 4 3 Connector requirements 68 11 4 4 Electrical description 68 11 4 5 Pin descriptions 68 11 4 6 SAS transmitters and receivers 69 11 4 7 Power 69 11 5 Signal characteristics 69 11 5 1 Ready L...

Page 6: ...ance vs Power Limit Settings IOPs chart 38 Figure 11 960GB Light Endurance Performance vs Power Limit Settings IOPs chart 39 Figure 12 480GB Light Endurance Performance vs Power Limit Settings IOPs chart 39 Figure 13 3840GB Scalable Endurance Performance vs Power Limit Settings IOPs chart 40 Figure 14 1920GB Scalable Endurance Performance vs Power Limit Settings IOPs chart 40 Figure 15 Current pro...

Page 7: ... regarding Warranty Support visit http www seagate com support warranty and replacements For information regarding data recovery services visit http www seagate com services software seagate recovery services recover For Seagate OEM Distribution partner portal and reseller portal visit http www seagate com partners Seagate Technology Support Services ...

Page 8: ...D D and Self Encrypting Drive models Note Previous generations of Seagate Self Encrypting Drive models were called Full Disk Encryption FDE models before a differentiation between drive based encryption and other forms of encryption was necessary Note The Self Encrypting Drive models indicated on the cover of this product manual have provisions for Security of Data at Rest based on the standards d...

Page 9: ...ed on the TCG Storage Architecture Core Specification and the TCG Storage Workgroup Security Subsystem Class Enterprise_A specification with additional vendor unique features as noted in this product manual 2 2 1 Electromagnetic compatibility The drive as delivered is designed for system integration and installation into a suitable enclosure prior to use The drive is supplied as a subassembly and ...

Page 10: ... of Measurement Korean KCC If these drives have the Korean Communications Commission KCC logo they comply with KN22 and KN24 Taiwanese BSMI If this model has the Taiwanese certification mark then it complies with Chinese National Standard CNS13438 2 2 3 European Union Restriction of Hazardous Substances RoHS The European Union Restriction of Hazardous Substances RoHS Directive restricts the presen...

Page 11: ... number 100293071 ANSI SAS Documents SFF 8144 54mm x 78 5mm Form Factor with micro serial connector SFF 8223 2 5 Drive Form Factor with Serial Connector SFF 8460 HSS Backplane Design Guidelines SFF 8470 Multi Lane Copper Connector SFF 8482 SAS Plug Connector ANSI INCITS xxx Serial Attached SCSI SAS 3 Standard T10 2212 D ISO IEC 14776 xxx SCSI Architecture Model 5 SAM 5 Standard T10 2104 D ISO IEC ...

Page 12: ... and do not attempt to service items in the enclosure The drive does not contain user replaceable parts Opening for any reason voids the drive warranty 3 1 Standard features 1200 2 SSD drives have the following standard features 3 0 6 0 12 0 Gb Serial Attached SCSI SAS interface Integrated dual port SAS controller supporting the SCSI protocol Support for SAS expanders and fanout adapters 128 deep ...

Page 13: ...h 524 and 528 byte block sizes Table 1 Formatted Capacity Block Count 3 2TB 1 6TB 800GB 400GB models Capacity Blocks Block Size 3840GB 3200GB 1920GB Decimal Hex Decimal Hex Decimal Hex 512 7 814 037 168 1D1C0BEB0h 6 251 233 968 1749A42B0h 3 907 029 168 E8E088B0h 520 7 648 717 976 1C7E62C98h 6 118 974 384 16CB823B0h 3 824 358 992 E3F31650h 524 7 546 770 672 1C1D294F0h 6 037 416 536 167DBAA58h 3 773...

Page 14: ...d and other factors Single unit shipping pack The drive is normally shipped in bulk packaging to provide maximum protection against transit dam age Units shipped individually require additional protection as provided by the single unit shipping pack Users planning single unit distribution should specify this option The Safety and Regulatory Agency Specifications part number 75789512 is usually inc...

Page 15: ... 100293068 A logical block provisioning management enabled LBPME bit set to one indicates that the logical unit implements logical block provisioning management An LBPME bit set to zero indicates that the logical unit is fully provisioned and does not implement logical block provisioning management A logical block provisioning read zeros LBPRZ bit set to one indicates that for an unmapped LBA spec...

Page 16: ...eld returned in the READ CAPACITY 16 parameter data If the host attempts to access an unmapped LBA on a drive that has been formatted with Protection Information PI the drive shall return scrambled PI data for that LBA Depending on the value of the RDPROTECT field in the data access command CDB this may result in the drive returning a standard PI error to the host If the host reduces the addressab...

Page 17: ...an average of all possible page to page accesses for a sequentially preconditioned drive Average response time is a true statistical random average of at least 5000 measurements of accesses between programma ble pages on a randomly preconditioned drive Table 4 Typical Response Time μsec All capacities 1 2 1 Execution time measured from receipt of the Command to the Response 2 Assumes no errors 3 T...

Page 18: ... Provisioned DCRT 1 IP 0 5 5 5 5 Non SED Fully Provisioned DCRT 0 IP 1 10 10 10 10 Non SED Fully Provisioned DCRT 1 IP 1 10 10 10 10 SED Default Thin Provisioned DCRT 0 IP 0 5 5 5 5 SED Default Thin Provisioned DCRT 1 IP 0 5 5 5 5 SED Fully Provisioned DCRT 0 IP 1 430 430 430 430 SED Fully Provisioned DCRT 1 IP 1 280 280 280 280 Configuration Format Mode DCRT Bit IP Bit 960GB 8000GB 480GB 400GB 20...

Page 19: ...Mix 3 45 000 Standard 2 5 Models Mainstream Endurance Notes ST3200FM0023 ST3200FM0033 ST3200FM0043 ST1600FM0003 ST1600FM0013 ST1600FM0023 ST800FM0173 ST800FM0183 ST800FM0213 ST400FM0233 ST400FM0243 ST400FM0293 Maximum Burst Transfer Rate 2000 MB s Sustained sequential 128KB read write data transfer rate MB s max 1 1900 850 1900 625 Sustained 4KB random read write command rate IOPs 2 200 000 80 000...

Page 20: ... time The drive accepts the commands listed in the SAS Interface Manual less than 4 seconds after DC power has been applied If the drive receives a NOTIFY ENABLE SPINUP primitive through either port and has not received a START STOP UNIT command with the START bit equal to 0 the drive becomes ready for normal operations within 10 seconds excluding the error recovery procedure If the drive receives...

Page 21: ...s the ability of the data to be written to non volatile medium in the event of an unexpected power loss The SYNCHRONIZE CACHE command may be used to force the drive to write all cached write data to the medium Upon completion of a SYNCHRONIZE CACHE command all data received from previous WRITE commands will have been written to the medium Section 11 3 2 shows the mode default settings for the driv...

Page 22: ... op erating and storage temperature over the specified product life For the specific workload to achieve this level of endurance please reference JEDEC Specification JESD218 TBW is defined as 1x1012 Bytes 4 Limited Warranty with Media Usage provides coverage for the warranty period or until the SSD Percentage Used Endurance Indicator as defined in Section 5 2 6 reaches 100 whichever comes first Un...

Page 23: ... needed to ensure reliable product operation 5 2 2 Garbage Collection Garbage Collection is a technique used by the drive to consolidate valid user data into a common cell range freeing up unused or obsolete locations to be erased and used for future storage needs Garbage Collection is automatically managed by the drive and requires no user interaction The Seagate algorithm is tuned to operate onl...

Page 24: ...al units The AFR MTBF specification is based on the following assumptions for Enterprise Storage System environments 8760 power on hours per year 250 average on off cycles per year Operations at nominal voltages Systems will provide adequate cooling to ensure the case temperatures specified in Section 6 3 are not exceeded Temperatures outside the specifications in Section 6 3 will increase the pro...

Page 25: ...saved to the media so that the events that caused a predictive failure can be recreated The drive measures and saves parameters once every hour subject to an idle period on the drive interfaces The process of measuring off line attribute data and saving data to the media is interruptible The maximum on line only processing delay is summarized below Reporting control Reporting is controlled by the ...

Page 26: ... bit and the reporting mechanism is controlled by the Method of Reporting Informational Exceptions field MRIE on the Informational Exceptions Control IEC mode page 1Ch 5 3 6 Drive Self Test DST Drive Self Test DST is a technology designed to recognize drive fault conditions that qualify the drive as a failed unit DST validates the functionality of the drive at a system level There are two test cov...

Page 27: ... the extended test option is to empirically test critical drive components The read operation tests the media contents The integrity of the media is checked through a read verify scan of the media The anticipated length of the Extended test is reported through the Control Mode page 5 3 6 2 4 Log page entries When the drive begins DST it creates a new entry in the Self test Results Log page The new...

Page 28: ...original box Seagate approved containers are easily identified by the Seagate Approved Package label Shipping a drive in a non approved container voids the drive warranty Seagate repair centers may refuse receipt of components improperly packaged or obviously damaged in transit Contact the authorized Seagate distributor to purchase additional boxes Seagate recommends shipping by an air ride carrie...

Page 29: ...starting current must be available to each device 6 1 1 Conducted noise immunity Noise is specified as a periodic and random distribution of frequencies covering a defined frequency Maximum allowed noise values given below are peak to peak measurements and apply at the drive power connector 6 1 2 Power sequencing The drive does not require power sequencing The drive protects against inadvertent wr...

Page 30: ...o media access com mands having been received from the host 6 2 1 Direct Current Consumption by Voltage Rail Table 7 Mainstream Endurance 2 5 model DC power requirements Parameter 3200GB 12 0Gb Mainstream Endurance Regulation 4 5 5 2 Voltage 5V 12V 2 Current A Current A Power W Average idle current 1 DC 0 59 0 20 5 40 Maximum starting current peak DC DC 0 94 0 61 12 06 peak AC AC 2 05 1 01 22 37 D...

Page 31: ...ed start max DC 1 3 3σ 0 53 0 13 4 19 Operating current random read Typical DC 1 DC 0 69 0 14 5 13 Maximum DC 1 3σ 0 71 0 15 5 37 Maximum peak DC 3σ 0 98 0 24 7 78 Operating current random write Typical DC DC 0 76 0 30 7 44 Maximum DC 3σ 0 78 0 33 7 90 Maximum peak DC 3σ 1 72 0 82 18 44 Operating current sequential read Typical DC DC 0 96 0 21 7 33 Maximum DC 3σ 0 98 0 22 7 56 Maximum peak DC 3σ 2...

Page 32: ...ed start max DC 1 3 3σ 0 49 0 02 2 75 Operating current random read Typical DC 1 DC 0 71 0 06 4 27 Maximum DC 1 3σ 0 72 0 06 4 37 Maximum peak DC 3σ 1 10 0 18 7 66 Operating current random write Typical DC DC 0 68 0 20 5 74 Maximum DC 3σ 0 70 0 21 6 01 Maximum peak DC 3σ 1 22 0 50 12 10 Operating current sequential read Typical DC DC 0 80 0 09 5 10 Maximum DC 3σ 0 81 0 10 5 20 Maximum peak DC 3σ 1...

Page 33: ...4 Delayed start max DC 1 3 3σ 0 56 0 26 5 89 Operating current random read Typical DC 1 DC 0 71 0 22 6 17 Maximum DC 1 3σ 0 72 0 24 6 42 Maximum peak DC 3σ 0 96 0 52 Operating current random write Typical DC DC 0 77 0 44 9 18 Maximum DC 3σ 0 79 0 50 9 90 Maximum peak DC 3σ 1 40 0 96 Operating current sequential read Typical DC DC 1 02 0 35 9 29 Maximum DC 3σ 1 04 0 38 9 72 Maximum peak DC 3σ 2 12 ...

Page 34: ... ground returns 3 Where power is provided to multiple drives from a common supply careful consideration for individual drive power require ments should be noted Where multiple units are powered on simultaneously the peak starting current must be available to each device 4 Parameters other than start are measured after a 10 minute warm up Table 11 Light Endurance 2 5 model DC power requirements Par...

Page 35: ... Manual Rev A 34 6 2 2 Drive Performance Based on Power Setting Figure 1 3200GB Mainstream Endurance Performance vs Power Limit Settings IOPs chart Figure 2 1600GB Mainstream Endurance Performance vs Power Limit Settings IOPs chart ...

Page 36: ...te 1200 2 SAS SSD Product Manual Rev A 35 Figure 3 800GB Mainstream Endurance Performance vs Power Limit Settings IOPs chart Figure 4 400GB Mainstream Endurance Performance vs Power Limit Settings IOPs chart ...

Page 37: ...eagate 1200 2 SAS SSD Product Manual Rev A 36 Figure 5 3200GB Light Endurance Performance vs Power Limit Settings IOPs chart Figure 6 1600GB Light Endurance Performance vs Power Limit Settings IOPs chart ...

Page 38: ...Seagate 1200 2 SAS SSD Product Manual Rev A 37 Figure 7 800GB Light Endurance Performance vs Power Limit Settings IOPs chart Figure 8 400GB Light Endurance Performance vs Power Limit Settings IOPs chart ...

Page 39: ...agate 1200 2 SAS SSD Product Manual Rev A 38 Figure 9 3840GB Light Endurance Performance vs Power Limit Settings IOPs chart Figure 10 1920GB Light Endurance Performance vs Power Limit Settings IOPs chart ...

Page 40: ...eagate 1200 2 SAS SSD Product Manual Rev A 39 Figure 11 960GB Light Endurance Performance vs Power Limit Settings IOPs chart Figure 12 480GB Light Endurance Performance vs Power Limit Settings IOPs chart ...

Page 41: ...te 1200 2 SAS SSD Product Manual Rev A 40 Figure 13 3840GB Scalable Endurance Performance vs Power Limit Settings IOPs chart Figure 14 1920GB Scalable Endurance Performance vs Power Limit Settings IOPs chart ...

Page 42: ...ent profiles The 12V and 5V current profiles for the Seagate 1200 2 SAS SSD 2 5 drives are shown below Figure 15 Current profiles for 800GB standard and 400GB High Endurance models Figure 16 Current profiles for 400GB standard and 200GB high endurance models ...

Page 43: ...Seagate 1200 2 SAS SSD Product Manual Rev A 42 Figure 17 Current profiles for 200GB standard and 100GB high endurance models ...

Page 44: ...e drive assumes the operating environment is designed to maintain nominal internal temperature The rated MTBF is based upon a sustained internal temperature of 122 F 50 C Occasional excursions in operating temperature between the rated MTBF temperature and the maximum drive operating internal temperature may occur without impact to the rated MTBF temperature However continual or sustained operatio...

Page 45: ...on 10 3 6 3 4 1 Shock a Operating normal The drive as installed for normal operation shall operate error free while subjected to intermittent shock not exceeding 1000 Gs at a maximum duration of 0 5ms half sinewave Shock may be applied in the X Y or Z axis Shock is not to be repeated more than once every 2 seconds Note This specification does not cover connection issues that may result from testin...

Page 46: ... does not cover connection issues that may result from testing at this level b Operating abnormal Equipment as installed for normal operation shall not incur physical damage while subjected to periodic vibration Vibration occurring at these levels may degrade operational performance during the abnormal vibration period Specified opera tional performance will continue when normal operating vibratio...

Page 47: ...on exposing any electronic components to uncontrolled chemical pollutants and corrosive chemicals as electronic drive component reliability can be affected by the installation environment The silver copper nickel and gold films used in Seagate products are especially sensitive to the presence of sulfide chloride and nitrate contaminants Sulfur is found to be the most damaging Materials used in cab...

Page 48: ...or detailed mounting configuration dimensions See Section 10 3 Drive mounting Note These dimensions conform to the Small Form Factor Standard documented in SFF 8201 and SFF 8223 found at www sffcommittee org Figure 19 Mounting configuration dimensions 2 5 7mm models Weight 2 5 models 0 220 pounds 100 grams ...

Page 49: ...Seagate 1200 2 SAS SSD Product Manual Rev A 48 Figure 20 Mounting configuration dimensions 2 5 15mm models ...

Page 50: ...tested National Voluntary Laboratory Accreditation Program NVLAP accredited laboratories perform cryptographic module compliance conformance testing Seagate Enterprise SED The SEDs referenced in this Product Manual have been validated by CMVP and have been thoroughly tested by a NVLAP accredited lab to satisfy FIPS 140 2 Level 2 requirements In order to operate in FIPS Approved Mode of Operation t...

Page 51: ... unique data encryption key is used for each of the drive s possible16 data bands see Section 8 5 8 2 Controlled access The drive has two security providers SPs called the Admin SP and the Locking SP These act as gatekeepers to the drive security services Security related commands will not be accepted unless they also supply the correct credentials to prove the requester is authorized to perform t...

Page 52: ... drive is configured with a single data band called Band 0 also known as the Global Data Band which comprises LBA 0 through LBA max The host may allocate Band1 by specifying a start LBA and an LBA range The real estate for this band is taken from the Global Band An additional 14 Data Bands may be defined in a similar way Band2 through Band15 but before these bands can be allocated LBA space they m...

Page 53: ...A and a commensurate increase of about 150mW in power consumption There is no additional drain on the 12V supply See the tables in Section 6 2 1 for power requirements on the standard non SED drive models 8 9 Supported commands The SED models support the following two commands in addition to the commands supported by the standard non SED models as listed in Table 15 SECURITY PROTOCOL OUT B5h SECUR...

Page 54: ...o more information on the drive Error Recovery philosophy is presented in the SAS Interface Manual The drive uses a vendor unique format to report defects via the READ DEFECT DATA command pending T10 standardization of a format for Solid State Devices This format defect type is defined as 110b in the SCSI FORMAT UNIT command The definition of the 110b format is defined in the following table Table...

Page 55: ...ere are 4 types of Protection Information Type 0 Describes a drive that is not formatted with PI information bytes This allows for legacy support in non PI systems Type 1 Provides support of PI protection using 10 and 16 byte commands The RDPROTECT and WRTPROTECT bits allow for checking control through the CDB Eight bytes of Protection Information are transmitted at LBA boundaries across the inter...

Page 56: ...e drive is only required if the application requires a different logical block size Figure 22 Physical interface 10 1 Drive orientation The drive may be mounted in any orientation All drive performance characterizations however have been done with the drive in horizontal level and vertical drive on its side orientations which are the two preferred mounting orientations 10 2 Cooling Cabinet cooling...

Page 57: ...ction of the fourth mounting point when a known force F is applied to the fourth point 10 4 Grounding Signal ground PCBA and case ground are connected together in the drive and cannot be separated by the user The equipment in which the drive is mounted is connected directly to the drive with no electrically isolating shock mounts If it is desired for the system chassis to not be connected to the d...

Page 58: ...ddress The two ports have the capability of independent port clocking e g both ports can run at 12Gb s or the first port can run at 12Gb s while the second port runs at 6Gb s The supported link rates are 1 5 3 0 6 0 or 12 0 Gb s Subject to buffer availability the Seagate 1200 2 SAS SSD drives support Concurrent port transfers The drive supports receiving COMMAND TASK management transfers on both p...

Page 59: ...aracteristics page B1h Y Date Code page C1h Y Device Behavior page C3h Y Device Identification page 83h Y Extended Inquiry Data page 86h Y Firmware Numbers page C0h Y Jumper Settings page C2h N Power Conditions page 8Ah Y Power Consumption page 8Dh Y Supported Vital Product Data page 00h Y Thin Provisioning page B2h Y Unit Serial Number page 80h Y Vendor Unique page D1h Y Vendor Unique page D2h Y ...

Page 60: ...ode Sense 6 15h Y 3 Mode Select 10 Same Pages As Mode Sense 6 55h Y Mode Sense 6 1Ah Y 3 Caching Parameters page 08h Y Control Mode page 0Ah Y Disconnect Reconnect 02h Y Error Recovery page 01h Y Format page 03h N Information Exceptions Control page 1Ch Y Background Scan mode subpage 1Ch 01h Y Notch and Partition Page 0Ch N Protocol Specific LUN mode page 18h Y Protocol Specific Port page 19h Y Ph...

Page 61: ...rted 3Ch Y non SED drives only Error history 3Ch 1Ch Y Read Capacity 10 25h Y Read Capacity 16 9Eh 10h Y Read Defect Data 10 37h Y Read Defect Data 12 B7h Y Read Long 10 3Eh Y non SED drives only Read Long 16 9Eh 11h Y non SED drives only Reassign Blocks 07h Y Receive Diagnostic Results 1Ch Y Supported Diagnostics pages 00h Y Translate page 40h N Release 6 17h Y Release 10 57h Y Report Identifying...

Page 62: ... Diagnostics 1Dh Y Supported Diagnostics pages 00h Y Translate page 40h N Set Identifying Information A4h 06h Y Set Timestamp A4h 0Fh Y Start Unit stop Unit 1Bh Y Synchronize Cache 35h Y Synchronize Cache 16 91h Y Test Unit Ready 00h Y Unmap 42H Y Verify 10 2Fh Y BYTCHK bit Y Verify 12 AFh N Verify 16 8Fh Y Verify 32 7Fh 000Ah Y Write 6 0Ah Y Write 10 2Ah Y DPO bit Y FUA bit Y Write 12 AAh N Write...

Page 63: ...d is supported N No Command is not supported A Support is available on special request Write Buffer Modes 0 2 Supported 3Bh Y non SED drives only Write Buffer 3Bh Download Application Log 3Bh 1Ch Y Firmware Download option modes 5 7 Ah and Bh 2 Y non SED drives only Firmware Download option modes 4 5 7 Y SED drives only Write Long 10 3Fh Y Write Long 16 9Fh 11h Y Write Same 10 41h Y PBdata N LBdat...

Page 64: ...FM0023 53 54 31 39 32 30 46 4D 30 30 32 33 ST1920FM0043 53 54 31 39 32 30 46 4D 30 30 34 33 ST1920FM0053 53 54 31 39 32 30 46 4D 30 30 35 33 ST1600FM0003 53 54 31 36 30 30 46 4D 30 30 30 33 ST1600FM0013 53 54 31 36 30 30 46 4D 30 31 31 33 ST1600FM0023 53 54 31 36 30 30 46 4D 30 31 32 33 ST1600FM0073 53 54 31 36 30 30 46 4D 30 31 37 33 ST1600FM0083 53 54 31 36 30 30 46 4D 30 32 38 33 ST960FM0003 53...

Page 65: ... standard OEM drives the saved values are taken from the default values list and stored into the saved values storage location on the media prior to shipping 3 Current values Current values are volatile values being used by the drive to control its operation A MODE SELECT command can be used to change the values identified as changeable values Originally current values are installed from saved or ...

Page 66: ...ovided within this section The operational aspects of the Seagate SAS drives are provided in the SAS Interface Manual Figure 24 Physical interface Table 17 Miscellaneous features Supported Feature or condition N Automatic contingent allegiance N Asynchronous event notification Y Segmented caching N Zero latency read Y Queue tagging up to 128 queue tags supported Y Deferred error handling Y Paramet...

Page 67: ... 08 1 27 6X 1 27 14X 15 875 0 35MIN 15 875 33 43 0 05 B 4 90 0 08 0 84 0 05 22X 0 15 B P15 P1 S7 S1 SEE Detail1 0 30 0 05 4X 4 00 0 08 0 15 D 0 30 0 05 2X 41 13 0 15 B B C C A A 0 20 B 42 73 REF C OF DATUM D L 1 10 R0 30 0 08 4X 2 00 3X 5 08 0 45 0 03 7X 0 10 M E 4 65 0 80 6X 7 62 5 92 0 52 0 08 x 45 ...

Page 68: ... 05 x 45 5X 0 40 0 05 X 45 3X CORING ALLOWED IN THIS AREA 2 25 0 05 4 85 0 05 0 10 B E S14 S8 4 40 0 15 SEE Detail 2 3 90 0 15 SECTION A A SECTION C C A 0 35 0 05 45 R0 30 0 08 C 1 95 0 08 0 08 0 05 1 23 0 05 0 08 0 05 Detail 2 CONTACT SURFACE FLUSH TO DATUM A 0 03 65 30 1 90 0 08 SECTION B B 2 40 0 08 0 10 A D ...

Page 69: ...in descriptions This section provides a pin out of the SAS device and a description of the functions provided by the pins Table 19 SAS pin descriptions Short pin to support hot plugging 1 Behind a SAS Drive plug connector P1 and P2 are only connected to each other NC No connection in the drive Pin Signal name Signal type Pin Signal name Signal type S1 Port A Ground P1 Reserved 1 S2 Port A_in Diff ...

Page 70: ... as possible among the pins Current to the drive through the long power pins may be limited by the system to reduce inrush current to the drive during hot plugging 11 5 Signal characteristics This section describes the electrical signal characteristics of the drive s input and output signals See Table 19 for signal type and signal name information 11 5 1 Ready LED Out The Ready LED Out signal is d...

Page 71: ...he DFE circuit can derive an optimal equalization characteristic to compensate for many of the receive losses in the system 2 A Feed Forward Equalizer FFE optimized to provide balanced receive margins over a range of channels bounded by the best and worst case channels as defined by the relevant ANSI standard 11 7 Additional information Please contact the Seagate representative for SAS electrical ...

Page 72: ...ited States 408 658 1000 ASIA PACIFIC Seagate Singapore International Headquarters Pte Ltd 7000 Ang Mo Kio Avenue 5 Singapore 569877 65 6485 3888 EUROPE MIDDLE EAST AND AFRICA Seagate Technology SAS 16 18 rue du Dôme 92100 Boulogne Billancourt France 33 1 4186 10 00 Publication Number 100773817 Rev A September 2015 ...