Section 01 ENGINES (1503 4-TEC)
Subsection 03 (PTO HOUSING AND MAGNETO)
Installation
Reinstall removed parts in the reverse order.
CAUTION:
When installing PTO seal on super-
charged engines, make sure to position the
Oetiker clamps as shown in the picture.
1
R1503motr367A
1. Oetiker clamps
COUPLING
Removal
Lock crankshaft with locking tool (P/N 529 035
821). Refer to CYLINDER BLOCK section.
Remove:
– PTO seal as described above
– coupling
no. 12
using impeller remover/installer
(P/N 529 035 820).
529035820
CAUTION:
Apply some oil on the tool to protect
the seal located in the PTO coupling.
R1503motr48A
TYPICAL
Inspection
Check if seal
no. 13
is brittle, cracked or hard.
Check coupling for worn splines.
If damaged, replace faulty part.
R1503motr49A
Installation
For installation, reverse the removal procedure.
However, pay attention to the following.
Torque PTO coupling to 250 N•m (184 lbf•ft). Ap-
ply Loctite anti-seize (P/N 293 800 070) on threads.
STATOR
Removal
Remove:
– PTO housing (refer to PTO HOUSING RE-
MOVAL elsewhere in this section)
– holding plate
no. 14
with CPS
no. 15
smr2005-032
35