Section 01 ENGINES (1503 4-TEC)
Subsection 04 (LUBRICATION SYSTEM)
Using a vernier depth gauge, measure side wear
as shown.
1
R1503motr131A
2
1. PTO housing surface
2. Vernier depth gauge
R1503motr132A
1
2
1. Oil pump outer rotor surface
2. Vernier depth gage
Difference between pump housing and outer rotor
should not exceed 0.1 mm (.004 in). If so, replace
the complete oil pump assembly.
NOTE:
When the axial clearance of the oil pump
shaft assembly increases, the oil pressure de-
creases.
Check the inside of oil pump housing and its cover
for scoring or other damages and replace if dam-
aged.
Installation
For installation, reverse the removal procedure.
Pay attention to the following details.
NOTE:
Never use oil in the press fit area of the
rotary seal.
Push coolant/oil pump shaft seal in place by using
thumb.
1
R1503motr128A
1. Oil seal
Install the new rotary seal by using the rotary seal
pusher (P/N 529 035 823).
529036014
CAUTION:
Never use a hammer for the rotary
seal or coolant/oil pump shaft installation. On-
ly use a press to avoid damaging the ceramic
component.
SMR2005-035
53
www.SeaDooManuals.net