OWNER
’
S MANUAL
(
SEA ISUZU FSR/FSD EV)
SEA-OWS-QA-004/5
ISSUE DATE:
30/05/2020
Page
39
of
56
11- Trouble Shooting Guide
Caution:
Under no circumstances are users to carry out work on high voltage components. This must only be
done by a SEA-Electric technician.
•
The vehicle does not start
Fault diagnosis
Handling methods
12/24v start battery has gone flat
Charge or replace the battery
Isolator switch is in off position
Cycle switch
and ensure it is firmly in the ‘On’
position
Ensure handbrake is on and brake pedal is
depressed while attempting to start
If these conditions are met, contact SEA-Electric
to arrange diagnostic
•
Vehicle has derated (Become sluggish or accelerating poorly)
Fault diagnosis
Handling methods
The coolant level has dropped
Top up cooling system (Refer to section 9)
The radiator fans are not running
Check Low voltage fuse (as per diagram FB01).
If fine, check connectors are ok.
The Cooling pump is not running
Check Relay is in correctly (as per diagram FB02)
If fine, check connectors are ok.
•
Poor braking performance
Fault diagnosis
Handling methods
Vacuum pump failure
(For vacuum over hydraulic system only)
Ensure that vacuum pump is running when
ignition is turned on
Check fuse in FB01
Brake fluid level has dropped
(For vacuum over hydraulic system only)
Top up brake fluid level.
If OK, Contact SEA-Electric for diagnostic
Air compressor failure
(For air brake system only)
Ensure that air filter on compressor is not blocked
If OK, Contact SEA-Electric for diagnostic
•
Brake deviation
Fault diagnosis
Handling methods
Tyre pressures are not uniform.
Adjust to specified pressure.
Tyre tread wear is uneven
Wheel alignment and tyre replacement required
Unbalanced load
Average the load.
The clearance between the brake drum and the
brake shoes uneven.
Refer to OEM for adjustment