Modem in an industrial metal aluminum case which 
is  suitable  for  installation  into  a  control  cabinet. 
Modem has two communication ports (RS232 and 
USB) with adjustable watchdog. The modem is equipped with a GSM module Gemalto 
(Cinterion) BGS5  rel.2.  Thanks  to  standard  RS232  and  USB  interface,  the  modem  is 
suitable for fast implementation in devices that require remote communication. It also 
includes the monitoring of communication with the master device (watchdog), both via 
RS232 serial port as well as the USB. 
The modem has JAVA OPEN PLATFORM in which you can write your own program, for 
example a program for downloading and sending data from connected technology. 
For RS232 and USB parameter setting see the chapter 7.4. 
Modem can be powered directly from the USB connector. 

2.

 

Package Content 

1pc  GSM modem  
1pc  2-pin connector 3,5mm  

3.

 

Recommended Accessories 

3.1

 

Antenna 

GSM-ANT11K 

2dB, Whip jointed antenna, without cable  

GSM-ANT01S 

5dB, magnetic, cable 3m  

GSM-ANT51S 

9dB, magnetic, cable 3m 

GSM-ANT07S 

9,5dB log–per, cable 10m  

3.2

 

Power Supply 

GSM-PWR12 

Power supply adapter into socket 230V

AC 

/ 12V

DC

, 1A 

 

GSM-PWR1  

DIN rail mounted supply module  230VAC / 12VDC, 1.25A 

Note: for DIN rail mounting inside of a cabinet suitable: 
GSM-75-DIN 

Plastic DIN rail holder      or 

GSM-ZIP50  

Industrial 3M Dual-Lock ZIP 25x50mm for wall mounting 

3.3

 

Cables 

HW-11.99.6218 

CANON MD9-FD9 (connected as an extension), length 1.8 m  

HW-11.99.8752 

USB 2.0 AB (micro USB to a modem), length 1.8m 

4.

 

Technical Specification 

Parametr 

Symbol 

MIN. 

TYP. 

MAX. 

Unit 

Power Supply 

(PWR) 

Voltage DC 

 

7 V

DC

 

8 až 30 

 

33 V 

V

DC

 

Standby power. 
consumption 

Max. power. 
consumption 

connected to 

GSM network 

(call o GPRS) 

0,36 (30mA for 12 V

DC

 

2.1 

 

POWER 
supply conn. 

2-pin removable screw terminal block, pitch 3.5 mm (PWR), 

or micro USB connector 

Power supply 

via  USB 

Voltage  

Current 

 

 

120 

 

360 

mA 

Ingress 

Protection 

IP 

 

 

40 

 

 

Temperature 

Storage 

tSTG 

-40 

 

+85 

°C 

Operating 

tA 

-30 

 

+65 

°C 

Humidity 

Operating 

 

 

 

95 

% R.V. 

Dimensions 

Width 

54 

mm 

Height 

24 

mm 

Length 

82 

mm 

Weight 

 

 

0.103 

kg 

Note: If the power supply and USB connectors are connected at the same time, current 
goes only from power supply connector. 

5.

 

Modem Parameters 

Parameter 

Description 

GSM , GPRS 12  

 

850/900/1800/1900 MHz 
(GPRS 85.6 kbps DL, 85.6 kbps UL) 

Antenna connector 

Device -  SMA (F), 50 Ohm 

Internet services 

TCP/UDP server/client, DNS, Ping, FTP client, HTTP client 

JAVA 

2 MB RAM and 4 MB Flash File System 

USB 2.0 

Micro USB; USB2.0 

RS232 

CANON 9F; 120 to 921600 bps fix bit rate. Autobauding is available. 

Factory setting is 115200 baud, 8 data bits, no parity, 1 stop bit 

HW watchdog 

HW Watchdog is available for both RS232 and USB. Note: Watchdog 

setting is available only via RS232. 

6.

 

Documentation 

USB driver

 (driver for RS232 port is not needed), a list of 

AT

 

commands

 and other 

information, visit the 

www.seapraha.cz

 , type “GSM-BGS5-E2N” into the search box.  

In the Name field, enter the text 

sea

. In the Password box, type 

siemens

 

If you are using WIN10 and you will use only control via AT commands, do not 
download the driver, WIN10 will install its own driver automatically. 

7.

 

Hardware 

7.1

 

Power supply and it’s indication 

Supply voltage is connected to terminals PWR and must be 
in the  range  of  7-33  V

DC

. The  device is protected against 

overvoltage and has a built-in refundable SMD fuse. If the external fuse is needed, use 
1.25 A fuse at V

CC

 line. As the power consumption from USB is higher than 100mA, it is 

sometimes needed to reserve the current or use powered USB hub.  
The modem can be powered directly from the USB connector, even using RS232. 
If the modem uses power supply from USB cable, the communication is posible only via 
USB (not vir RS232. For communication via RS232 you must use external power supply 
(GSM-PWR12). 
LED PWR is located on the bottom-right side of PWR connector, LED RS232 is located 
bottom-left side of RS232 connector.  

LED 

COLOR 

MEANING 

PWR 

green 

dark 

… device is not supplied, or internal power 

convertor is out of order 

light 

… device in operation state 

RS232 

yellow 

Blinking     

… communication from the GSM module

   

 

7.2

 

NANO SIM card reader and GSM state indication 

Insert  the  nano  SIM  card  into  the  holder  (cut  corner  first, 
contacts up - towards the inscription SIM). The correct insertion 
is indicated by mechanical click noise. Push gently and release 
to remove the SIM card. 
Above  the SIM card  holder is located  the  LED which  indicates 
status of GSM. 

LED 

COLOR 

MEANING 

Located 
above  SIM 

card  holder 

SIM 

blue 

Device state indication. 

Dark 

… device failure; Device was switched of using 

AT command  

blinking 1:1 

… device starting up 

1 short blink per 4 seconds

 … device operational 

7.3

 

Antenna 

The antenna is connected via SMA connector. The device is fitted with SMA female. The 
connected antenna must have SMA male. The impedance is 50 Ω. 

7.4

 

Communication ports (RS232 and micro-USB) 

To communicate with the modem (AT commands) is designed interface RS232 and USB. 
The  device  includes  a  female  connector  RS232  and  micro-USB.  The  modem  can  be 
controlled using both interfaces, for setting up of the watchdog function is possible to 
use only RS232 interface.  
Factory default baud rate for communication with the modem for RS232 is 

115200bps, 

8 data bits, no parity, 1 stop bit. 

For changing the rate, see the Chapter „RS232 

Setting“.

 

Baud rate for USB is not needed to set.  

You will see two COM ports in WIN Control panel. For sending AT commands you must 
use the port, which you find in Device Manager „Modems“ (Parameters/Modem). Other 
port is determined for JAVA application´s development.

 

7.5

 

DIN rail mounting 

If you need to place the device into the switchboard on DIN rail, screw the plastic holder 
GSM-75-DIN drilled hole in the side of the modem.  

8.

 

Warranty 

General warranty period is 24 months after purchase, when eventual malfunction device will be repaired free of charge in 

SEA spol. s r.o. while shipping to SEA is paid by customer and SEA pays for shipping back to customer. 
The warranty does not cover any damage caused by wrong use which does not comply the technical specifications and 
user instructions and any accidental damage (e.g. by water, lightening etc.). 
SEA spol. s r.o. has NO RESPONSIBILITY for any damage, lost, costs and any other problems 

direct or inducted, caused by device malfunction from any reason. 

In case of incompleteness or any damage in the packaging it is necessary to inform SEA spol. s 

r.o. immediately (within five days). 

 

CE Declaration of conformity 

in accordance with the Radio and Telecommunications Terminal Equipment Directive 
1999/5/EC (R&TTE) and Directive 2011/65/EU (ROHS). 

We 

SEA, spol. s r.o., Dolnoměcholupská 21, CZ 102 00 Praha 10, 

ID

: 47117931 (

manufacturer

)

 

declare under our sole responsibility, that  product 

GSM modem with serial ports RS232 a 

 

USB 

type   

GSM-BGS5-

E2N 

is in conformity with the following standards:

 

health and safety: 

EN 62368-1:2015 + Opr.1:2016 + A11:2017 

EMC: 

 

EN 301489-1 v2.1.1   EN 301489-52 v1.1.0 

radio frequency: 

EN 301 511 v 12.1.10 

 

  

Place of issue: 

Praha

 

Name: 

Ing. Vladimír Rosůlek

 

Date of issue: 

19.7.2018 

Grade: 

director 

 

Reviews: