Sea Tel COBHAM Installation And Operation Manual Download Page 1

 

 

Sea Tel, Inc.  
(trading as Cobham SATCOM) 
4030 Nelson Avenue 
Concord, CA   94520 
Tel:   +1 (925) 798-7979 
Fax:  +1 (925) 798-7986 
 

 

Thrane and Thrane A/S  
(trading as Cobham SATCOM)  
Lundtoftegaardsvej 93 D, 2800 Kgs.  
Lyngby, Denmark 
Tel:   +45 3955 8800  
Fax:  +45 3955 8888 
 

Web: 

 

http://www.cobham.com/satcom

                                

Email:  

[email protected]

 

December 15, 2017   

Document No. 99-158223-A  

Sea Tel Marine Radome Air Conditioner   

Installation and Operation Manual

 

 

 

 

 

 

 

 

 
 

 

Summary of Contents for COBHAM

Page 1: ...7986 Thrane and Thrane A S trading as Cobham SATCOM Lundtoftegaardsvej 93 D 2800 Kgs Lyngby Denmark Tel 45 3955 8800 Fax 45 3955 8888 Web http www cobham com satcom Email satcom ohc cobham com Decembe...

Page 2: ...Sea Tel is an ISO 9001 2008 registered company Certificate Number 13690 originally issued on March 14 2011 and renewed reissued on March 10 2014 Copyright Notice Copyright 2017 Sea Tel Inc All Rights...

Page 3: ...Sea Tel Marine Radome Air Conditioner iii Revision History REV ECO Date Description By A December 15 2017 Production Release ECM...

Page 4: ...Sea Tel Marine Radome Air Conditioner iv This Page Intentionally Left Blank...

Page 5: ...e control 3 7 3 3 1 Protection function 3 7 3 3 2 Additional function 3 7 3 3 3 Fault code table 3 7 3 3 4 4 INSPECTION AND OPERATIONAL NOTES 4 8 4 1 INSPECTIONS 4 8 4 2 COMPRESSOR OVERLOAD PROTECTOR...

Page 6: ...ompressor with powerful cooling capacity Pre charged and pre wired system for convenient use Intelligent control system designed to be easy to operate Designed to operate in a harsh marine environment...

Page 7: ...ly conductive dust is present such as from Iron carbon casting aluminum etc Electric shock or fire caused by a short circuit can occur Keep away from fire The unit can become deformed or short circuit...

Page 8: ...ation in the 1 dome that will not interfere with the movement of the antenna Internal units must be accessible and have a clear area below the dome for condenser 2 intake discharge openings There must...

Page 9: ...ch supplies the ADE BDE equipment of the Marine SATCOM Terminal Be EXTREMELY cautious of length of the run for voltage loss and gauge of the wires for the current that is expected to be drawn The Powe...

Page 10: ...2 This icon will be lit and flashing when the compressor is not running 3 This icon will not be displayed when the machine is turned off Wind Speed Icon 1 This icon will be lit when the machine is tu...

Page 11: ...ns Temperature control 3 3 1 When the machine reaches within 1 of the set point temperature the unit will automatically switch to proper operational state The control logic where Ts Set Point Temp is...

Page 12: ...cord and the circuit breaker connected correctly If not connect them correctly Are the ducts deformed or torn Replace ducts with new ones Are the fins of the heat exchanger broken Return the unit for...

Page 13: ...hose clamp please install these in the A C drain port and route discharged water as required The amount of condensed water that the unit produces depends on the temperature and humidity of the enviro...

Page 14: ...pply then open electric box check wiring diagram and correct if necessary 7 The compressor overload protector has tripped The unit will reset itself automatically Wait for the unit to reset press the...

Page 15: ...ance Internal maintenance 5 1 1 Check the condenser coil for build up of dust or soot Wipe with a dry cloth Clean as needed and check annually To clean fan and other internal parts please consult with...

Page 16: ...Sea Tel Marine Radome Air Conditioner Troubleshooting Maintenance 5 12 99 158223 A 5 3 Main PCB Wiring Diagram 5 4 Controller Wiring Connection Diagram...

Page 17: ...Troubleshooting Maintenance Sea Tel Marine Radome Air Conditioner 5 13 99 158223 A 5 5 Product Diagram...

Page 18: ...Troubleshooting Maintenance Sea Tel Marine Radome Air Conditioner 5 1 99 158223 A This Page Intentionally Left Blank...

Page 19: ...Consumption 1700W 2100W Max Weight 55 kg 121 3 lbs Protection Class IPX4 Full Load Amps 7 7A 9 5A Max Refrigerant Type R407C Refrigerant Mass 830g 29 3 Oz Max Discharge Pressure 2 8MPa Max Suction Pr...

Page 20: ...223 A 7 Drawings 7 1 Sea Tel Marine Air Conditioner Drawings Drawing Title 88 207254 000 Air Conditioner External Outline Demensions 7 3 37 156302 Power Cord Cir BRK to Air Conditioner 6ft 7 4 97 1581...

Page 21: ...Sea Tel Marine Radome Air Conditioner Drawings 7 2 99 158223 A This Page Intentionally Left Blank...

Page 22: ...O INSTALL SELECTED PIPE FITTING SLIP HOSE CLAMP OVER HOSE END C SLIDE HOSE OVER SELECTED PIPE FITTING AND D TIGHTEN HOSE CLAMP DISCARD SURPLUS PIPE FITTING OR RETAIN FOR E USE ELSEWHERE IP 56 CONTROL...

Page 23: ...19364 BELDEN 2 EA 3 121899 14 TERMINALS PIN 14 AWG GRY 9004730000 WEIDMILLER 3 EA 3 111398 2 SPADE TERMINAL BLU INSULATED 6 18 14 AWG 14RB 6F THOMAS BETTS 4 EA 2 31 207380 003 RING TERMINAL BARE SHAN...

Page 24: ...ING RADOME BASE 123724 ASSEMBLY DRAWING RADOME BASE FRAME 41 123726 NNNN DRAWING RADOME BASE PAN 75 TOOLS REQUIRED Phillip head screw driver Flat tip screw driver 7 16 wrench socket wrench Channel loc...

Page 25: ...ble gland Kit using a Phillips head screw driver and the hardware that comes with the kit 2 Install item 4 DRAIN HOSE STRAIN RELIEF KIT using channel lock pliers 3 Using item 5 apply the 1 inch gasket...

Page 26: ...exhaust face the new vent hole using a 7 16 wrench socket wrench 5 Using item 20 through 29 Loctite the 1 4 20 bolts are to be torque to 50 in oz 20 28 28 29 4X 6 Using a 1 Phillips head screw drive...

Page 27: ...lamp over the hose and fitting and tighten with the flat tip screw driver as shown 32 31 30 8 Mount controller to side of AC a Remove the cover of the controller using a Phillips tip screw driver b Mo...

Page 28: ...INSTRUCTION NUMBER REV 97 158189 A 01 SHEET 5 OF 5 10 Route the power cable to the air conditioner circuit breaker...