SELECT RADOME FAB ASS'Y 109119 AS PER
SPECIFICATIONS IN CUSTOMERS SALES ORDERS.
1.
NOTES: UNLESS OTHERWISE SPECIFIED
2.
APPLY MASKING TAPE ALONG VERTICAL AND
HORIZONTAL EDGES OF ALL PANELS PRIOR TO CAULKING.
USE SILICON ADHESIVE TO SEAL VERTICAL AND
HORIZONTAL EDGES OF ALL PANELS, RADOME CAP, AND
BASE PAN UNDER PANELS.
3.
APPLY ADHESIVE PER SEA TEL SPEC 121730 TO ALL
THREADED FASTENERS AT TIME OF FINAL ASSEMBLY AND
TORQUE TO SEA TEL SPEC. 122305.
4.
BASED ON WIND VELOCITY OF 100 MPH:
HORIZONTAL WIND SHEAR: 870 LBS.
VERTICAL LIFT EACH LEG MAX.: 580 LBS.
OVERTURNING MOMENT: 6,380 FT. LBS.
5.
USE DRAWING IN CONJUNCTION WITH P/N: 124818-3.
6.
ORIENT RADOME PANEL FAB W/SIDE ACCESS SO
A SIDE SEAM IS INLINE WITH THE PAN ACCESS (AFT).
7
RADOME HW KIT (P/N: 124818-3) CONTAINS EXTRA HW.
8.
LK
STRAIN RELIEF WAS 109258-8
11-7-05
5050
N
CK
ADDED DASH 27
10-17-07
N/A
N1
SL
UPDATE BOM PER RED LINES. UPDATE VIEW TO SHOW DETAIL ASSY. UPDATE DASH TABLE AND RE-NUMBERS FOR NOTES
PER RED LINES. UPDATE UNITS FOR NOTE 5.
02-10-10
7046
P
K.D.H.
ADD -28; UPDATE TITLE BLOCK.
9-2-10
N/A
P1
DASH TABLE
DASH NO.
CONFIGURATION
COLOR
FOAM
SIDE ACCESS
-2
WHITE
YES
NO
-17
WHITE
YES
YES
-18
WHITE
YES
YES
-21
US NAVY GREY
YES
YES
-26
DANISH NAVY GREY
YES
YES
-27
SNOW WHITE
YES
YES
-28
DANISH NAVY GREY
YES
NO
X.XXX =
.020
X.XX =
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
WEIGHT:
DESIGNER/ENGINEER:
PROJECTION
FINISH:
MATERIAL:
DRAWN BY:
APPROVED BY:
TITLE:
FIRST USED:
SIZE
SCALE:
SHEET NUMBER
DRAWING NUMBER
REV
B
MAB
6/13/1997
1:35
111365
P1
1 OF 2
DRAWN DATE:
APPROVED DATE:
RADOME ASS'Y, 144 IN
REVISION HISTORY
REV ECO# DATE
DESCRIPTION
BY
2
1
.5
INTERPRET TOLERANCING PER ASME Y14.5 - 2009
916.915 LBS.
UNLESS OTHERWISE SPECIFIED
Tel. 925-798-7979 Fax. 925-798-7986
SURFACE ROUGHNESS:
.005
ANGLES:
N/A
N/A
3rd ANGLE
DIMENSIONS ARE IN INCHES.
X.X = .050
This drawing and specifications are the property
of Cobham PLC. Neither this document, the
information, or the specifications disclosed shall
be reproduced or transferred in whole or in part
for any purpose without the specific written
authorization of Cobham PLC. This restriction
is applicable regardless of the source from which
the document is obtained. Any violation of this policy
is a violation of the Trade Secrets Act and subject
to prosecution to the fullest extent of the law.
DETAIL B
SEE DETAIL C
SEE DETAIL A
SEE
1
BASE FRAME ASS'Y
REF ONLY
PAN ACCESS
INSIDE
W/SIDE ACCESS
RADOME CAP
OUTSIDE
RADOME PANAL FAB
72 SPH.
RAD.
RAD. MIN.
70.5 SPH.
RADOME PANEL FAB 7
Summary of Contents for 9711QOR-86
Page 4: ......
Page 14: ...Table of Contents xiv This Page Intentionally Left Blank ...
Page 26: ...Site Survey 9711QOR 86 C Ku Band TXRX 2 8 This Page Intentionally Left Blank ...
Page 70: ...Installation 9711QOR 86 C Ku Band TXRX 3 44 This Page Intentionally Left Blank ...
Page 74: ...Basic Setup of the ACU 9711QOR 86 C Ku Band TXRX 4 4 This Page Intentionally Left Blank ...
Page 78: ...Setup Ships Gyro Compass 9711QOR 86 C Ku Band TXRX 6 2 This Page Intentionally Left Blank ...
Page 80: ...Setup Band Reflector Select 9711QOR 86 C Ku Band TXRX 7 2 This Page Intentionally Left Blank ...
Page 86: ...Setup Home Flag Offset 9711QOR 86 C Ku Band TXRX 9 4 This Page Intentionally Left Blank ...
Page 90: ...Setup Targeting 9711QOR 86 C Ku Band TXRX 10 4 This Page Intentionally Left Blank ...
Page 96: ...Setup Searching 9711QOR 86 C Ku Band TXRX 11 6 This Page Intentionally Left Blank ...
Page 122: ...Antenna Specific Operation 9711QOR 86 C Ku Band TXRX 16 12 This Page Intentionally Left Blank ...
Page 126: ...Functional Testing 9711QOR 86 C Ku Band TXRX 17 4 This Page Intentionally Left Blank ...
Page 190: ...Drawings 9711QOR 86 C Ku Band TXRX 23 2 This Page Intentionally Left Blank ...
Page 196: ......
Page 199: ......
Page 233: ......
Page 234: ......
Page 239: ......
Page 241: ......
Page 243: ......