D-RFID-PR3 - v1.04 / 2012-09-21 

Strana 1 z 2 

D-RFID-PR3 Manual  

 

1.

 

Introduction 

D-RFID-PR3

 (

PR3

  for short)  is external RF receiver module for PLC FATEK.  PR3 

receives  codes  from  433 MHz  transmitters  (

in  system  SEA  D-RFID

)  and  sends 

them to RS485 serial channel (9600 Baud, 7 bits, even parity, 1 stop bit) in protocol 
FATEK. 

 

 

Main Features 

 

External RF receiver module for PLC FATEK 

 

RF Data coding - 

system SEA D-RFID

 

 

Operates in free 433 MHz band 

 

Serial communication: RS485 – FATEK protocol 

 

 
 

2.

 

Package 

1 pc  

PR3

 (order code D-RFID-PR3) 

 

 

 

Warning 

Transmitter 

D-RFID

 and 

PLC FATEK

 are not part of 

PR3

 package and 

has to be ordered separately. 

PR3

 can be connected to any PLC FATEK, 

which  is  equipped  with  RS 485  communication  port  (e.g.  FAC-FBS-CB5). 

PR3

 

accepts only RF signals transmitted in system SEA D-RFID (e.g. 

D-RFID

 which can 

transmit codes for 2 year on internal battery). 

 
 

 
 

 

 
 

3.

 

Typical application 

  

 
 

4.

 

Installation 

1.

 

Connect PR3 to PLC and switch on the power supply. All LEDs on PR3 are 

dark.  (In  case  the  red  LED  lights,  check  the  PLC  serial  port  3  setting 
(9600Bd, even parity, 1 stop bit), if it does not help, try to exchange A and 

B RS485 wires). 

2.

 

Locate the D-RFID transmitter near PR3. The green LED RF diode on PR3 

starts to blink once per 10 sec. 

3.

 

Test the simple PLC program using WinProladder. (see the simple example 
at the end of this document)  

 
 

5.

 

Technical specification 

Parameter 

Symbol 

Conditions 

MIN. 

TYP 

MAX 

Unit 

Dimensions 

Width 

w/o cables 

 

70 

 

mm 

Height  

 

 

70 

 

mm 

Depth 

 

 

27 

 

mm 

Supply 

Voltage  DC 

V

CC

 

(typically 
car battery) 

12 

30 

V

DC

 

Current 

I

CC

 

V

CC

 = 12V  

 

 

 

mA 

 

 

 

 

 

Output 
RS 485 

Number 

 

 

 

Protocol FATEK 

 

http://fatek.esea.cz 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature 

Operational 

t

A

 

 

-20 

 

+55 

°C 

Rel. humidity 

Operational 

h

A

 

 

 

 

90 

 

 
 

6.

 

Hardware 

 
  

 

 
 

 
 

 

 
 

 
 

 

 
 

 
 

 
 

 

 

 

6.1

 

Indicators (LED diodes), Attenuator 

 

 

 

 
 

 
 

 

 
 

 
 

 
 

 

 

 

6.2

 

Connector 

 

 

 
 

 

 
 

 
 

 
 
 

 
 

 

7.

 

Control 

 

7.1

 

Common operation 

Whenever any valid data  packet  is received the 

green RF  LED

 shortly blinks and 

M1801 register in connected PLC is set. 

 

 

7.2

 

Received signal gain setting 

Turn the red rod on attenuator until the requested gain of PR3 is reached. 
 

 

8.

 

Communication protocol 

8.1

 

Common operation 

PR3

  sends  data  (using  FATEK  protocol)  to  RS 485  serial  line  with  information 

concerning  received  data  from  D-RFID  transmitters.  Serial  line  setting  is  this: 
9600 Baud, 7 bits, even parity, 1 Stop bit.  

 

Example of debug data: 
<#02>014708R030005052010800000000000D000000000037AE<#03><#0D> 

 
Example of data concerning D-RFID transmitters: 

<#02>014904M18011DR03008443932C1DR0301000002C9DDR03012000000A518<
#03><#0D> 

 

 
 

 

Name 

LED diode 

Description 

RF 

LED green 

Lights whenever valid RF data 
packet is received. 

ERR 

LED red 

Lights whenever any problem in 
communication with PLC appears   

DBG 

LED red 

For debug purposes only 

ATT 

Attenuator 

RF signal gain setting  

Pushbutton 

Not used 

Pin 

 

Description 

Supply: +8 to +30 V

DC

 

RS 485: A (Data +) 

RS 485: B (Data -) 

GND 

Ground: (Supply and RS 485) 

 

+8 to +30 V

DC

RS 485: A
RS 485: B

GND

Attenuator

Min gain

Max gain

LED ERR

LED RF