Section 04 FUEL SYSTEM
Subsection 03 (FUEL TANK AND FUEL PUMP)
Set the vacuum/pressure pump to vacuum.
smr2009-031-013_a
1. Vacuum selected
Install a
SMALL HOSE PINCHER (P/N 295 000 076)
near outlet valve.
295000076
Connect vacuum/pressure pump to the vent hose
end.
smr2009-031-015_a
TEST SETUP
Squeeze the vacuum/pressure pump handle sev-
eral times to draw air in through the inlet valve.
Air should be drawn in freely and vacuum pres-
sure indication on gauge should remain at zero. If
vacuum value rises, replace inlet valve.
Set vacuum/pressure pump to pressure.
smr2009-031-012_a
1. Pressure selected
Squeeze the vacuum/pressure pump handle sev-
eral times to pressurize air to the inlet valve.
smr2009-031-015_b
TEST SETUP
Valve should hold 34.5 kPa (5 PSI) without leak-
age. Otherwise, replace inlet valve.
When replacing valve, always reinstall it with the
black side as shown.
smr2006-026-004
Reinstall valve in its grommet.
Reinstall remaining removed components.
smr2009-031
261
Summary of Contents for GTX Limited iS 255 2009
Page 1: ......
Page 2: ...2009 Shop Manual RXT iS 255 GTX LIMITED iS 255 ...
Page 23: ...XX smr2009 011 ...
Page 27: ...4 ...
Page 29: ...6 ...
Page 33: ...10 ...
Page 37: ...14 ...
Page 47: ...24 ...
Page 53: ...30 ...
Page 59: ...36 ...
Page 81: ...58 ...
Page 107: ...84 ...
Page 171: ...148 ...
Page 195: ...172 ...
Page 209: ...186 ...
Page 235: ...212 ...
Page 275: ...252 ...
Page 303: ...280 ...
Page 319: ...296 ...
Page 335: ...312 ...
Page 381: ...358 ...
Page 395: ...372 ...
Page 449: ...426 ...
Page 489: ...466 ...
Page 551: ......
Page 552: ...NOTES ...
Page 553: ...NOTES ...
Page 554: ...2009 Sea Doo 4 TEC iTC iS Series RXT iS 255 GTX Limited iS 255 smr2009 045 001 ...
Page 555: ...IGNITION SYSTEM CHARGING SYSTEM STARTING SYSTEM smr2009 045 002 ...