Application

• 

24V DC Chain Motor.

• 

Natural and Smoke Ventilation 

applications

• 

Configurable:

• 

Speed

• 

Stroke

• 

Seal Relief

• 

Volt Free Contact (optional)

• 

Range of Fixing Systems.

• 

Options for customisation to meet 

application requirements.

• 

       Marked

• 

Tested to principles of EN1210-2: 2003 

Annex G

Summary of Contents for SECO Ni 24 40

Page 1: ...ns for future reference and maintenance Subject to technical modifications Diagram is not binding Application 24V DC Chain Motor Natural and Smoke Ventilation applications Configurable Speed Stroke Se...

Page 2: ...Operating Speed 600mm 12mm sec 900mm 15mm sec Ambient Operating Temp 5 C 60 C Thrust Force 400N Close Force 400N Soft Close Yes Switching Electronic Standard Finish Powder coated Grey RAL 9006 Seal Re...

Page 3: ...h attention must be paid All actuator products contain metallic plastic and electronic parts Redundant electronic products are classified as hazardous waste under the WEEE regulations Waste Electrical...

Page 4: ...f the cables in relation to the cable lengths and power consumption Care must be taken to ensure that actuator products are controlled with compatible products refer to SE Controls No liability will b...

Page 5: ...All smoke ventilation systems must be periodically annually checked serviced maintained and if necessary repaired and re tested by a authorised trained and competent safety conscious persons Maintena...

Page 6: ...Subject to technical modifications Diagram is not binding A Top hung open out window B Bottom hung open in window C Top hung open out window on sill 3 Still fixing option 4 Face fixing option 5 Open...

Page 7: ...runnion set 2 on the moving part of the window Caution misalignment will cause improper opening and closing of the window iii Fix all screws in the trunnion set and pivot bracket firmly make sure suff...

Page 8: ...nt space is allowed for the actuator body to rotate iv Fix the pin to connect the trunnion set to the top part of the chain v Switch on the power supply to test run the actuator for a few cycles make...

Page 9: ...ster House Wellington Crescent Fradley Park Lichfield Staffordshire WS13 8RZ Company No 01468061 Vat No 377 5600 30 SE Controls is a Registered Trademark Lancaster House Wellington Crescent Fradley Pa...

Reviews: