background image

 

 

 

 

SECO Ni Folding Arm Actuator

 

Fixed Version - Technical information and operating 

 

instructions

 

+44 (0)1543 443060

 

 

 

[email protected]

 

 

 

www.secontrols.com

 

Please keep these operating instructions for future reference and maintenance. 

 

Subject to technical modifications. Diagram is not binding.

 

SECO Ni Folding Arm 

 

 

 

Fixed Version

 

• 

 

24

 

V dc Fixed Folding Arm 

 

• 

 

Smoke & Environmental Ventilation 

 

applications

 

• 

 

Configurable:

 

• 

 

Speed

 

• 

 

Stroke

 

• 

 

Seal Relief

 

• 

 

Volt Free Contact

 

• 

 

Range of Fixing Systems.

 

• 

 

Options for customisation to meet 

 

application requirements.

 

• 

 

CE Marked

 

Bracket Part Numbers

 

 

 

AKS20000003 - Pivot/Slider Kit

 

AKS20000002 - Mounting Bracket Kit

 

Summary of Contents for SECO AKS20000002

Page 1: ...and maintenance Subject to technical modifications Diagram is not binding SECO Ni Folding Arm Fixed Version 24V dc Fixed Folding Arm Smoke Environmental Ventilation applications Configurable Speed St...

Page 2: ...Please keep these operating instructions for future reference and maintenance 44 0 1543 443060 Subject to technical modifications Diagram is not binding sales secontrols com www secontrols com...

Page 3: ...aw Amp 1 0A Stroke Opening Angle 0 600mm 0 90 programmable Operating Speed 15mm sec Ambient Operating Temp 5 C to 60 C Thrust Force 400N Close Force 400N Soft Close Yes Switching Electronic Standard F...

Page 4: ...hese operating instructions for future reference and maintenance 44 0 1543 443060 Subject to technical modifications Diagram is not binding sales secontrols com www secontrols com Synchronisation Opti...

Page 5: ...Please keep these operating instructions for future reference and maintenance 44 0 1543 443060 Subject to technical modifications Diagram is not binding sales secontrols com www secontrols com...

Page 6: ...tionary warning with numerous implications Danger Danger that could cause personal injury Danger of hands been crushed Warning Danger of electric shock 1 2 Health and Safety Electrical Safety Warning...

Page 7: ...Please keep these operating instructions for future reference and maintenance 44 0 1543 443060 Subject to technical modifications Diagram is not binding sales secontrols com www secontrols com...

Page 8: ...the cables in relation to the cable lengths and power consumption Care must be taken to ensure that actuator products are controlled with compatible products refer to SE Controls No liability will be...

Page 9: ...Please keep these operating instructions for future reference and maintenance 44 0 1543 443060 Subject to technical modifications Diagram is not binding sales secontrols com www secontrols com...

Page 10: ...Fire Safety Order 2005 In order to keep the equipment in optimum operating condition it is recommended that ventilation systems are similarly maintained There are no user repairable parts in this equ...

Page 11: ...Please keep these operating instructions for future reference and maintenance 44 0 1543 443060 Subject to technical modifications Diagram is not binding sales secontrols com www secontrols com...

Page 12: ...to the actuator 5 Mark up the distance from the hinge to the actuator to allow the door to be opened to the required position 8 Drive the actuator fully closed and allow the door to close ensure the...

Page 13: ...44 0 1543 443060 Technical Drawing Wiring Please keep these operating instructions for future reference and maintenance Subject to technical modification...

Page 14: ...Creating a healthier safer environment Wiring Electric Strike Wiring Magnet...

Page 15: ...Park Lichfield sales secontrols com Staffordshire WS13 8RZ www secontrols com Name registered office Loanguard Limited Lancaster House Wellington Crescent Fradley Park Lichfield Staffordshire WS13 8R...

Reviews: