Coolant Filter, Change
NOTICE!
Only applies to engines using Volvo Penta
Coolant (green). Engines using Volvo Penta Coolant
VCS are not fitted with coolant filters.
1 Turn the tap (1) 90° to stop the flow through the
coolant filter.
2 Remove the coolant filter with a suitable extractor.
Make sure that no residue from the old seal
remains in the housing.
3 Put a thin layer of engine oil on the new coolant
filter seal. Screw the coolant filter on by hand until
the seal comes into contact with the mating surface
of the filter bracket. Then tighten the coolant filter
a further 1/2 turn.
4 Turn the tap (1) 90° to release the flow through the
coolant filter again.
5 Start the engine and perform a leakage check.
6 Switch the engine off and check the coolant level.
Coolant Level, Checking and Topping
.
Cooling System, Cleaning
Cooling performance is reduced by deposits in the
radiator and cooling galleries. The cooling system
should be cleaned out when the coolant is changed.
IMPORTANT!
Cleaning must not be done if there is any risk of the
cooling system freezing, since the cleaning solution
does not have any frost prevention ability.
IMPORTANT!
It is extremely important that the correct concentration
and volume of coolant is put in the system. Mix in a
separate clean vessel before filling the cooling system.
Make sure that the liquids mix.
1 Empty the cooling system. Refer to
2 Put a hose into the expansion tank filling hole and
flush with clean water, as specified by Volvo Penta–
refer to section Water quality in
until the water draining out is com-
pletely clear.
3 If there should still be some contamination left after
flushing for a long time, cleaning can be done with
coolant. Otherwise, continue as in item 8 below.
4 Fill the cooling system with 15-20 % mixture of con-
centrated coolant. Use only Volvo Penta recom-
mended concentrated coolant mixed with clean
water.
Open
1
P0002099
Closed
1
P0002100
Maintenance
7748681 12-2011
71
199/297
Summary of Contents for R570U
Page 1: ...User and maintenance manual for generating sets R570U 33504081501NE_1_1 ...
Page 15: ...Alternator Cabinet Figure 1 3 Examples of identification plates 13 297 ...
Page 18: ...Sockets voltage 208 120V 16 297 ...
Page 125: ...9 Appendix 9 1 Appendix A Engine user and maintenance manual 123 297 ...
Page 126: ...124 297 ...
Page 128: ...126 297 ...
Page 129: ...OPERATOR S MANUAL Generating set and industrial engines 16 liter EMS 2 127 297 ...
Page 159: ...157 297 ...
Page 218: ...216 297 ...
Page 220: ...218 297 ...
Page 222: ...7748681 English 12 2011 220 297 ...
Page 223: ...9 2 Appendix B Alternator user and maintenance manual 221 297 ...
Page 224: ...222 297 ...
Page 226: ...224 297 ...
Page 250: ...www leroy somer com 248 297 ...
Page 261: ...Installation and maintenance R250 A V R 4067 en 2009 05 b LEROY SOMER 11 259 297 ...
Page 281: ...2012 03 e LEROY SOMER 19 Installation and maintenance R 450 AVRs 4531 en 279 297 ...
Page 282: ...www leroy somer com 280 297 ...