01/08/02

P:\INSTALLATION INST\Access Controls\INST-E3\INST-E3 Expansion Guide\INST-E3 Expansion Guide.doc     0102     Page 1

Summary of Contents for EntryCheck E3

Page 1: ...01 08 02 P INSTALLATION INST Access Controls INST E3 INST E3 Expansion Guide INST E3 Expansion Guide doc 0102 Page 1...

Page 2: ...the Door Status Contact if used 6 You must install the supplied Transorbs at the door strike as described in the installation guide 7 Connect the Door Strike or Door Lock 8 Double check all connection...

Page 3: ...01 08 02 P INSTALLATION INST Access Controls INST E3 INST E3 Wiring Guide INST E3 Wiring Guide doc 0102 Page 1...

Page 4: ...l the Door Status Contact if used 6 You must install the supplied Transorbs at the door strike as described in the installation guide 7 Connect the Door Strike or Door Lock 8 Double check all connecti...

Page 5: ...E3 EntryCheck Programming Manual FOR E3 FIRMWARE VERSION GREATER THAN 2 00 00 SDC 3580 Willow Lane Westlake Village CA Phone 805 494 0622 FAX 805 494 8861 www sdcsecurity com...

Page 6: ...OAD INSTRUCTION LOCATED IN ALL ORIGINAL E3 CD 0 1 2 E3 EntryCheck Release Notes E3 Status screen shows the Door Status The E3 Status screen will indicate if the door is locked or unlocked Particularly...

Page 7: ...ogramming 8 4 1 Configuration Wizard 8 4 1 1 Company Information 8 4 1 2 New Open Client Feature 9 4 1 3 Door Names 9 4 1 4 Door Assignments 10 4 1 5 Daylight Savings 10 4 2 Door Configuration 11 4 2...

Page 8: ...ultiple Panel SMMP 28 5 1 1 Panel Loop 29 5 2 Modem SMMP Programming 30 5 2 1 Computer Configuration 31 5 2 2 Modem Configuration 32 5 2 3 E3 EntryCheck Panel Communications 33 P INSTALLATION INST Acc...

Page 9: ...tware To install E3 EntryCheck for Windows 2000 XP the following requirements must be met Windows 2000 or Windows XP must be installed on the host computer User must have knowledge of mouse and keyboa...

Page 10: ...to find out what is the letter name of the CD ROM drive 2 Click on the Start Menu and then select Run 3 Type in the Letter of the CD ROM drive followed by setup Click OK This will start the loading pr...

Page 11: ...ortcut E3 will open to it s main page NOTE Section 3 0 is devoted to describing the basic layout of the E3 EntryCheckTM program and its different sub menus To continue with the programming of E3 pleas...

Page 12: ...ause the controllers to operate in a standalone mode until the program is restarted 3 1 2 View Menu Selection History Transactions Allows the operator to view all transactions as they are received fro...

Page 13: ...site codes 1 16 Site Codes Organize Database Optimizes and repairs database Export Data Allows an administrator to export the current E3 parameters Import Data Allows an administrator to import the c...

Page 14: ...n off 3 1 6 Window Menu Selection Close All Windows Closes all windows previously opened Reset Default Sizes Restores all windows to default sizes Cascade Arranges selected windows in a cascaded orien...

Page 15: ...figuration Wizard Configure Door Parameters Card Management Tool Authorization Groups Standard Time Periods Unlock Lock Door s Reset Windows to Default Sizes Close All Windows Author and Version More...

Page 16: ...ecurity com 1 Enter Your Name Company Name Address Phone number 2 Select Apply or OK Select Clear to begin over again 3 The Regional Setting will adjust Holiday List for E3 EntryCheck 4 Password will...

Page 17: ...e and reopen E3 EntryCheck This will default the settings of the software and will be ready to be changed It is mandatory to close and reopen E3 whenever switching between clients for changes to be ma...

Page 18: ...igned to each panel 2 Select Apply or OK to store the names 4 1 5 Daylight Savings The daylight savings times have been factory set until 2012 To correct or change any of the default dates you can cha...

Page 19: ...installed and is to be used to allow for push button opening of a controlled door Request to Exit Supervised Check box if the REX circuit is monitored for tampering using 4 state supervision Valid Ca...

Page 20: ...of extended time that the door will remain open until an alarm is triggered in those cases where additional time is required to get through the door Maximum setting is 255 seconds Auto Unlock Time Per...

Page 21: ...Configuration screen 4 2 3 1 Entry Exit on a Single Door E3 EntryCheck has the ability for entry exit capability on a single door By installing readers on either or both sides of an access point E3 c...

Page 22: ...ent someone from passing his or her card back to another user to allow entry into the door or gate Entry Exit Assignment Allows access to area controlled by a single panel two doors only Important Ins...

Page 23: ...or Decrement area inputs The High Count will turn on Local Alarm Maximum count will DISABLE door relays NOTE Area Counter is controlled by only one panel Each area is controlled one panel not multipl...

Page 24: ...either end and adjust its length to your requirements This will automatically update the Start and End columns as you change the size of the red bar OR 2 Double click a Start End and use the up down...

Page 25: ...idnight Use the same steps to change the Holiday Periods as you did above in the Standard Time Periods NOTE NEVER and ALWAYS are factory defaults and cannot be altered Select Apply or OK to save your...

Page 26: ...e current time is checked with the Time Period associated with the AG If the time is not valid an Invalid Time Period transaction will be generated and access will be denied To set up authorization gr...

Page 27: ...Click on the Detail tab to bring up the Detail screen NOTE The Activation Date defaults to today s date If the card activates on a different date than today then change the date NOTE All cards have a...

Page 28: ...time the door can stay open without triggering an alarm 11 Picture will add JPEG Picture File to card detail NOTE Must apply before moving to the next card detail to save any changes 12 Click on the r...

Page 29: ...ypad PIN is last 2 4 digits of PIN number Combine Alarm PIN User Number with Keypad PIN for user PIN number i e 01 and 11 pin number is 0111 4 7 3 Bulk Change Bulk Change allows data to be populated i...

Page 30: ...u the Import window appear 2 Select the E3 features that you wish to import see below 3 Click the OK button Save In window will appear with the title Choose a database to restore from with the default...

Page 31: ...ow appears 2 Select the E3 features that you wish to export to a different copy of E3 see below Click the OK button 3 A Save As window will appear with the title Choose a database file to back up to w...

Page 32: ...ppears near the bottom of the screen to give you the current status Broadcast to All Panels will download all panels on a loop To set Factory Defaults 1 Select the File menu item 2 Click the Factory D...

Page 33: ...rchive button You will be asked for the number of days prior to today to archive To archive the last week enter 7 to archive the last month enter 30 Archive will remove transaction from E3 Archive loc...

Page 34: ...th or without Site Code separation 1 Select Site codes from the Database top menu or vertical menu selection 2 Highlight dashes in Site Code column and type in site code number 3 Click on one of the S...

Page 35: ...rt you wish to print by highlighting it with the mouse 3 Now select the sorting mode you want 4 Select Preview to view the report on the screen before printing it out 5 Selecting the Print button afte...

Page 36: ...CABLEP N 04 10344 001 CABLEP N 04 10291 001 PWR LINE LINE PWR LiNC EZ PCSC COM 5 0 E3 EntryCheck Communication 5 1 Single Modem Multiple Panel SMMP E3 EntryCheck Cross Over Cable Null Cable IQX2 E3 2...

Page 37: ...Parity odd Stop bits 1 No Flow Control Wait for dial tone before dialing checked 5 1 1 Panel Loop The Panel Loop can handle 1 32 panels All panels must be wired as directed in installation manual RS...

Page 38: ...one number If no Secondary Phone number present then phone line will incorrectly dial second number Loop Phone Number Enter Phone number for panel Loop Dial button Will dial Loop Phone number Hang Up...

Page 39: ...the pop up window select the Hardware tab and click on Device Manager 2 Find and open Ports and double click on Communications Port COM 1 3 Select the Port Settings tab and change the settings to 9600...

Page 40: ...n Phone and Modem Options 2 Click on the New button in the Dialing Rules tab 3 Type in the location name and select the Country region and type in the area code Make sure that the Tone is selected for...

Page 41: ...pe from Serial to Modem and click on the Apply button 3 Click on the TAPI Modem tab and in the Loop Phone Number box type in the phone number to the E3 panel This is for communication between the PC a...