SDC Emlock 1511 Manual Download Page 1

sdcsecurity.com     [email protected]

SECURITY DOOR CONTROLS

EZ Option Upgrade Kits - 

Emlock© 1511, 1513, 1571, 1573

EMLock EZ Kits 

Field Upgradeable Option Modules for 1511, 1513, 1571, 1573

SDC’s patented EMLock design represents the pinnacle of magnetic lock evolution.

The modular EMLock assembly makes them easy to stock, install, upgrade and maintain.

 EZ-B-10 MAGNETIC 

BOND SENSOR

Modular Kit 

EZ-T-10 TIMER INPUT MODULE

Modular Kit

EZ-D-10: DOOR POSITION SENSOR

Modular Kit

 EZ-A: ANTI-TAMPER SWITCH

 Modular Kit

Field Upgradeable by Distributors, Installers and Maintenance Staff

No need to ever remove a lock from the frame to upgrade or exchange 

internal components.

FIELD UPGRADE

 

  • Relock Delay Timer 

  • Magnetic Bond Sensor

  • Door Status Sensors

  • Anti-Tamper Switch 

  • Holding Force Upgrade

  • Energy Saver Upgrade

Summary of Contents for Emlock 1511

Page 1: ...s them easy to stock install upgrade and maintain EZ B 10 MAGNETIC BOND SENSOR Modular Kit EZ T 10 TIMER INPUT MODULE Modular Kit EZ D 10 DOOR POSITION SENSOR Modular Kit EZ A ANTI TAMPER SWITCH Modul...

Page 2: ...1 3670 SECURITY DOOR CONTROLS 8 sdcsecurity com service sdcsecurity com EZ T 10 TIMER INPUT MODULE Modular Kit Relock Delay Timer Adjustable 1 to 30 Seconds Application The Timer Input Module delays r...

Page 3: ...en or closed SDC s Magnetic Bond Sensor provides higher security monitoring by indicating the locked unlocked mode tampering and low holding force The use of both the door status and magnetic bond sen...

Page 4: ...A 93011 3670 SECURITY DOOR CONTROLS 8 sdcsecurity com service sdcsecurity com EZ D 10 DOOR POSITION SENSOR Modular Kit Indicates the door is open and closed Application Door position status annunciati...

Page 5: ...l EZ 1570W Energy Saver Upgrade Save on power supply and long term energy costs by exchanging 8 4 Watt 1650 lb coil with 3 Watt 1200 lb holding force coil Eliminate labor shipping costs and time assoc...

Page 6: ...date qty vendor SECURITY DOOR CONTROLS www sdcsecurity com service sdcsecurity com t 800 413 8783 805 494 0622 f 805 494 8861 801 Avenida Acaso Camarillo CA 93012 PO Box 3670 Camarillo CA 93011 3670 S...

Page 7: ...tus module to each armature EZ D 10 DOOR POSITION SENSOR Modular Kit EZ A ANTI TAMPER SWITCH Modular Kit EMLock EZ Upgrade Kits Field Upgradeable Option Modules for 1512 and 1572 SDC s patented EMLock...

Page 8: ...Remove cover plate 2 6 Position timer modules between posts Cradle Position Posts 9 Attach cover plate T Timer input module Remove cover plate screws 1 Attach magnetic core wire connector to timer mo...

Page 9: ...p 4 3 4 5 6 7 8 Remove cover plate screws 1 2 Remove cover plate 6 9 Attach cover plate Place magnetic coil firmly between core lamination as shown Connect magnetic bond sensor wires to the input modu...

Page 10: ...Core Connector 12 or 24 VDC LOCKED NO COM UNLOCKED NC CLOSED NO COM OPEN NC Locked 3 4 3 4 Input module wiring Annunciation Replace cover plate Anti tamper wiring Com No NC B Option Connector B Option...

Page 11: ...B Option connector as shown 5 Connect upgrade coils 3 4 5 6 7 8 Input module wiring 8 B Option Connector B Option Magnetic Bond Sensor D Option Door Status Sensor Magnetic Core Connector 12 or 24 VDC...

Page 12: ...m t 800 413 8783 805 494 0622 f 805 494 8861 801 Avenida Acaso Camarillo CA 93012 PO Box 3670 Camarillo CA 93011 3670 SECURITY DOOR CONTROLS 8 sdcsecurity com service sdcsecurity com 2010 Security Doo...

Page 13: ...late Place anti tamper switch as shown Position cover depresses switch arm when mounted Anti tamper wiring Com No NC Locked Unlocked 3 4 2 NOT USED POWER DPS CO NC NO Magnetic Core Connector B Option...

Page 14: ...etic Secure se in place w screw as shown 5 The Magnetic Bond Sensor should be positioned as shown below after step 4 9 Attach co 4 Remove 1 screw from the case bottom Place the Magnetic Bond Sensor at...

Page 15: ...CLOSED NO COM OPEN NC 3 4 2 Input module wiring Annunciation Install lock per installation instructions Replace cover plate Place anti tamper switch as shown Position cover depresses switch arm when...

Page 16: ...Place the Magnetic Bond Sensor at the base of the Magnetic Core Secure sensor in place with screw as shown 8 Attach cover plate Cradle Position Posts PC Board 3 4 5 6 Remove cover plate screws 1 2 Rem...

Reviews: