SDC 1591U EMLOCK Installation Instructions Download Page 1

1591U EMLOCK

®

INSTALLATION INSTRUCTIONS

1.

Prepare door jamb for EMLock per template drawing.

2.

Locate reinforcement plate and mounting tabs as shown.

3.

Center Armature Plate to the centerline of the lock.  The cutout for the armature must be 1-1/2” wide
and 6-1/2” long.

4.

Install an armature reinforcement plate or the Amp mounting plate so that there is a 5/8” pocket when 
measured from the leading edge of the door. The AMP mounting plate is used to reinforce the mortise cutout 
in a wood door. It is secured to the door with four (4) #10 wood screws and then the EMLock armature is 
secured to the mounting plate with a 5/16”-18 x 3/4” bolt.

NOTE: The AMP mounting plate is an option available from SDC.

5.

Attach the EMLock wire leads to the power source and then install the EMLock and the armature with screws 
provided.

SYSTEM WIRING

ELECTRONICS

24V CONFIGURATION

BLK

RED

ORG
WHT

(+) RED/BLK

TO 24VDC (+/-10%)
FUSED, REGULATED 
& FILTERED POWER 
SOURCE

(-) WHT/BLK

RED

RED

ACCESS, EGRESS

AND 

REMOTE CONTROLS

+

-

ELECTRONICS

12V CONFIGURATION

BLK

RED

ORG

WHT

(+) RED/BLK

(-) WHT/BLK

RED

RED

ACCESS, EGRESS

AND 

REMOTE CONTROLS

+

-

IMPORTANT WIRING INFORMATION:

Use the system wiring diagram to configure the EMLock for 12 VDC or 24 VDC operation. 

Although using a DC power supply is recommended, a transformer with a bridge rectifier may also be used as a 
DC power source. If you are using a transformer and rectifier, a transformer with the correct output voltage must 
be used. Access controls must not be wired to the AC side of the bridge rectifier or power supply. Access 
controls must always be wired to break the DC side of the power source. 

P:\INSTALLATION INST\Electromagnetic Locks\INST-1591U.vsd       REV C       01-17       Page 1

801 Avenida Acaso, Camarillo, Ca. 93012  •   (805) 494-0622  •
www.sdcsecurity.com  •  E-mail: [email protected]

N/O

COM

N/C

GRY

YEL

ORG

(POLARITY SHOWN WITH 

THE DOOR OPEN)

1591U – DPS OPTION

TO 12VDC (+/-10%)
FUSED, REGULATED 
& FILTERED POWER 
SOURCE