Scully Connect Quick Start Manual Download Page 1

Scully Connect

®

 Testing Cable

(P/N 092000240)

User Guide

This cable accessory is designed to be field repairable. If any part of the 
cable breaks, it can be repaired using the instructions provided.

If a wire breaks on the banana plug end of the cable:

 

1. Unscrew the fastening termination screw inside
    the banana plug and remove any broken pieces
    of wire that may be stuck inside.
2. Strip away a ¼” length of insulation from the wire
    where it is broken.
3. The exposed wire can be tinned with a soldering
    iron or twisted and left as is.
4. Insert the wire into the banana plug and fasten
    it using the termination screw.

If a wire breaks on the Scully Connect

®

 end of the cable: 

1. Insert and push a thin, blunt tool into the connector.
2. Remove any broken pieces of wire that may be
    stuck in the connector.
3. Strip away a ¼” length of insulation from the
    wire where it is broken.
4. The exposed wire needs to be twisted and
    tinned with a soldering iron.
5. Insert the wire into the connector and ensure
    that it is properly inserted by gently tugging
    on the repaired wire.

603000004 Rev A

November 2018

F I E L D   R E P A I R

Scully Signal Company

70 Industrial Way, Wilmington, MA 01887-3479, USA
800 272 8559 • 617 692 8600 •

 

[email protected]

U.K.

+44 (0) 1606 553805 
[email protected]

Europe

+32 (0) 15 56 00 70 
[email protected]

India 

+91 9821799566 
[email protected]

1

1

4

Reviews: