![Scully Connect Quick Start Manual Download Page 1](http://html.mh-extra.com/html/scully/connect/connect_quick-start-manual_1220094001.webp)
Scully Connect
®
Testing Cable
(P/N 092000240)
User Guide
This cable accessory is designed to be field repairable. If any part of the
cable breaks, it can be repaired using the instructions provided.
If a wire breaks on the banana plug end of the cable:
1. Unscrew the fastening termination screw inside
the banana plug and remove any broken pieces
of wire that may be stuck inside.
2. Strip away a ¼” length of insulation from the wire
where it is broken.
3. The exposed wire can be tinned with a soldering
iron or twisted and left as is.
4. Insert the wire into the banana plug and fasten
it using the termination screw.
If a wire breaks on the Scully Connect
®
end of the cable:
1. Insert and push a thin, blunt tool into the connector.
2. Remove any broken pieces of wire that may be
stuck in the connector.
3. Strip away a ¼” length of insulation from the
wire where it is broken.
4. The exposed wire needs to be twisted and
tinned with a soldering iron.
5. Insert the wire into the connector and ensure
that it is properly inserted by gently tugging
on the repaired wire.
603000004 Rev A
November 2018
F I E L D R E P A I R
Scully Signal Company
70 Industrial Way, Wilmington, MA 01887-3479, USA
800 272 8559 • 617 692 8600 •
U.K.
+44 (0) 1606 553805
[email protected]
Europe
+32 (0) 15 56 00 70
[email protected]
India
+91 9821799566
[email protected]
1
1
4