background image

TB-9075

 Page 1 of 3

© 2017 DESCO INDUSTRIES, INC.

Employee Owned

SCS 

- 926 JR Industrial Drive, Sanford, NC 27332

East: (919) 718-0000 | West: (909) 627-9634 • Website: 

StaticControl.com

497AJL HEPA Vacuum

Installation, Operation and Maintenance

January 2017

 USER GUIDE TB-9075

Figure 1. 

497AJL

 HEPA Vacuum.

Grounding Instructions

This appliance must be grounded. If it should 

malfunction or break down, grounding provides a 

path of least resistance for electric current to reduce 

the risk of electric shock. This appliance is equipped 

with a cord having an equipment-grounding conductor 

and grounding plug. The plug must be used with an 

appropriate outlet that is properly installed and grounded 

in accordance with all local codes and ordinances.
This appliance is for use on a nominal 120-volt circuit. 

(Check inside each vacuum model motor lid for specific 

information.) Make sure the appliance is connected to 

an outlet having the same configuration as the plug. No 

adapter should be used with this appliance.

Any service on this vacuum cleaner should be performed 

by an authorized service representative.
This product meets ANSI/ESD S20.20 and is designed 

to be used in an ESD protected area; The hose and 

accessories are conductive/dissipative so electrostatic 

charges will be removed when properly grounded 

throught the power cord to electrical outlet ground prong.

Warning:

 Improper connection of the equipment-

grounding conductor can result in a risk of electric shock. 

Check with a qualified electrician or service person if 

you are in doubt as to whether the outlet is properly 

grounded. Do not modify the plug provided with the 

appliance. If the plug does not fit the outlet, have a 

proper outlet installed by a qualified electrician.

Made in the

United States of America

Specifications

Electrical

120VAC, 50/60Hz, 6.0amps

Motor

1 Horsepower

Dimensions

17.8" L x 7.8" W x 9.3" H 

(45.2 cm L x 19.7 cm W x 23.5 cm H)

Weight

11 lbs.

Certification

cULus

To Operate

1.  Release latches and open lid.

2.  Unfasten accessory door and remove vacuum hose, 

electrical cord and hose attachments. 

3. 

Remove filter plug from vacuum inlet (always 

replace when repacking for transport). 

4.  Attach selected accessory to hose. Insert other end 

of hose into inlet.

5.  Latch lid securely.

6.  Insert hooded end of power cord in power cord 

receptacle on vacuum.

7.  Plug cord into power outlet.

8.  Turn on power switch.

Figure 2. How to operate the 

497AJL

 HEPA Vacuum.

5