7 Parameter Description SV600 Series User Manual
150
Group PP: Function Code Management
Function
code
Name
Setting range
Default
Property
PP-00
User password
0-65535
0
☆
If it is set to any non-zero number, the password protection function is enabled. After a password
has been set and taken effect, you must enter the correct password in order to enter the menu. If
the entered password is incorrect you cannot view or modify parameters.
If PP-00 is set to 00000, the previously set user password is cleared, and the password protection
function is disabled.
Function
code
Name
Setting range
Default
Property
PP-01
Parameter initialization
0: No action
01: Restore factory settings, excluding motor
parameters
02: Clear record information
04: Back up user current parameters
501: Restore user backup parameters
0
★
01: Restore factory settings, excluding motor parameters
If PP-01 is set to 1, most function codes are restored to the default settings except motor
parameters, frequency reference resolution (P0-22), fault records, accumulative running time
(P7-09), accumulative power-on time (P7-13) and accumulative power consumption (P7-14).
02: Clear record information
If PP-01 is set to 02, the fault records, accumulative running time (P7-09), accumulative power-on
time (P7-13) and accumulative power consumption (P7-14) are cleared.
04: Back up user current parameters
If PP-01 is set to 04, the current parameter settings are backed up, helping you to restore the
setting if incorrect parameter setting is performed.
501: Restore user backup parameters
If FP-01 is set t501, the previous backup user parameters are restored.
Function
code
Name
Setting range
Default
Property
PP-02
Function parameter group
display selection
Units digit: U Group Display Selection
0: Not display
1: Display
Tens digit: Group A Display Selection
0: Not display
1: Display
11
★
The parameter is used to set whether display group U and group A parameters or not.
Function
code
Name
Setting range
Default
Property