7 Parameter Description SV600 Series User Manual
94
Group P4: Input Terminals
SV600 series inverter has 6 multi-function input terminals DI.
Function
code
Name
Setting range
Default
Property
P4-00
DI1 function selection
0: No function
1: Forward run (FWD)
2: Reverse run (REV)
(Note: Function 1 and 2 need to be used
according to the setting in P4-11, for more
details,please refer to the description of
parameters in Chapter 7)
3: 3-wire operation control
4: Forward JOG running
5: Reverse JOG running
6: Terminal UP
7: Terminal DOWN
8: Freely STOP
9: Fault Reset
10: Run pause
11: External Fault Input(NO Normal Open)
12: Multi-segment instruction terminal 1
13: Multi-segment instruction terminal 2
14: Multi-segment instruction terminal 3
15: Multi-segment instruction terminal 4
16: Acc./Dec. Time Selection Terminal 1
17: Acc./Dec. Time Selection Terminal 2
18: Frequency source switchover
19: UP/DOWN settings clear (Terminal,
Keyboard)
20: Control command switchover terminal 1
21: Acceleration/Deceleration prohibit
22: PID pause
23: PLC status reset
24: Swing Pause
25: Count input
26: Count reset
27: Length count input
28: Length reset
29: Torque control prohibit
30: HDI (Pulse) frequency input
31: Reserved
32: Immediate DC braking
1
★
P4-01
DI2 function selection
2
★
P4-02
DI3 function selection
4
★
P4-03
DI4 function selection
9
★
P4-04
HDI function selection
30
★
P4-05
DI5 function selection
0
★
P4-06
DI6 function selection
0
★