background image

 

 

Instruction Manual 

 

P/N 087-0045 Rev. E 01/10 

Masterdock™ 

Docking Station 

 

WARNING 

R

EAD AND FOLLOW THE ENTIRE CONTENT OF THIS MANUAL PRIOR TO 

USE

.

 

F

AILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH

C

OPYRIGHT 

©

 

2009,

 

SCOTT,

 

A

LL 

R

IGHTS 

R

ESERVED

 

Summary of Contents for Masterdock

Page 1: ...P N 087 0045 Rev E 01 10 Masterdock Docking Station WARNING READ AND FOLLOW THE ENTIRE CONTENT OF THIS MANUAL PRIOR TO USE FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH COPYRIGHT 2009 SCOTT A...

Page 2: ...Masterdock Docking Station Instruction Manual ii P N 087 0045 Rev E 01 10 This Page Left Intentionally Blank...

Page 3: ...3 2 Powering the Masterdock 10 3 3 Connecting Calibration Gas 10 3 4 Secure Digital Memory Card 11 3 4 1 Formatting an SD Card 12 3 5 Air Filter 12 3 6 Installing Software 12 4 Operation 13 4 1 Bump T...

Page 4: ...Masterdock Docking Station Instruction Manual iv P N 087 0045 Rev E 01 10 This Page Left Intentionally Blank...

Page 5: ...erdock Wall Mounting Dimensions 9 Figure 3 2 Installing Calibration Gas 10 Figure 3 3 Installing SD Memory Card 11 Figure 4 1 Masterdock Utility Main Display 15 Figure 4 2 Masterdock Utility Operation...

Page 6: ...Masterdock Docking Station Instruction Manual vi P N 087 0045 Rev E 01 10 This Page Left Intentionally Blank...

Page 7: ...truction Manual vii P N 087 0045 Rev E 01 10 List of Tables Table 1 1 Acronym Quick Reference List 5 Table 2 1 Masterdock Components 8 Table 4 1 Status LED Indications 13 Table 5 1 Parts List 19 Table...

Page 8: ...nual viii P N 087 0045 Rev E 01 10 Record of Revisions Revision Date Description A 04 09 Initial release B 08 09 Updated LED indications and troubleshooting table C 09 09 Updated P N s D 10 09 Updated...

Page 9: ...not used in accordance with the instructions If further operational or maintenance details are required but not provided in this manual contact Scott Health and Safety or their agent Scott Health and...

Page 10: ...e user attention Each warning caution or note is labeled and quickly identified using an icon WARNING INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH IF NOT AVOIDED COULD RESULT IN DEATH OR SERIOUS...

Page 11: ...AS THESE CAN CAUSE DAMAGE TO THE SENSORS OF THE PROT G 1 2 2 General Rules for Use of the Masterdock It is critical that this docking station be used and maintained properly Failure to do so could je...

Page 12: ...expressly permitted by SCOTT product manuals or by written authorization from SCOTT To obtain performance under this warranty and as a condition precedent to any duty of SCOTT the purchaser must retur...

Page 13: ...e 1 1 is a quick reference chart to quickly identify any acronym that may be unfamiliar to users Table 1 1 Acronym Quick Reference List Acronym Definition AC Alternating Current DC Direct Current FAT...

Page 14: ...Masterdock Docking Station Instruction Manual 6 of 20 P N 087 0045 Rev E 01 10 This Page Left Intentionally Blank...

Page 15: ...brations and testing for accurate record keeping The Masterdock can be powered using the included AC adapter or by installing four alkaline C cell batteries The Masterdock eliminates the need to conne...

Page 16: ...nents Table 2 1 Masterdock Components Number Component Number Component 1 Air Outlet 7 Bump and Calibration Activation Buttons 2 Calibration Gas Gauge 8 Calibration Gas Dock 3 Status LEDs 9 Air Inlet...

Page 17: ...ation such as mounted on a wall To mount the Masterdock on the wall drill four holes per the dimensions shown in Figure 3 1 Mounting hardware must not exceed 14 5 mm in diameter and be capable of supp...

Page 18: ...charge those batteries when connected to an external source Rechargeable batteries must be removed and charged in an external charger 3 3 Connecting Calibration Gas Insert either 58L or 34L cylinder o...

Page 19: ...o installation Slide the SD card into the slot fully until it clicks and close the cover To remove the SD card push the card in and allow it to release then pull the card out Keep the SD port cover cl...

Page 20: ...Open the My Computer icon on the desk top Locate the SD card it is typically identified as Removable Disk Right click and select Format When the Format Disk window appears set or verify the File Syste...

Page 21: ...Bump to perform a bump test or Cal to perform a calibration The LED above the selected button will turn off and the status LED will begin blinking orange 5 When the status LED lights green the Prot g...

Page 22: ...re 7 Select Operation Setup Port Select the COM number previously identified 4 3 2 Masterdock Utility Modes The Masterdock utility can be used in User Mode or Administrator Mode All options available...

Page 23: ...n Administrator Mode the options to sync time with the PC clock and Calibrate if a Bump test fails become available A toolbar located at the top of the display has three quick use buttons Get Configur...

Page 24: ...rations Used to poll the Masterdock about current information for display including the Firmware Revision Gas Lot Number Serial Number and Location of the Masterdock Operation Mode Used to select eith...

Page 25: ...2 Option Menu Language Used to Select which language for the Masterdock utility to display Figure 4 3 Masterdock Utility Option Menu 4 3 4 3 View Menu Toolbar Used to display or hide the Toolbar Stat...

Page 26: ...tation Instruction Manual 18 of 20 P N 087 0045 Rev E 01 10 4 3 4 4 Help Menu About Masterdock Utility Used to display the current software revision level of the Masterdock Utility Figure 4 5 Masterdo...

Page 27: ...libration Gas 58L 077 0352 5 1 Cleaning and Routine Maintenance The Masterdock is designed to be free of routine maintenance unless operated with batteries As needed replace batteries with C Cell batt...

Page 28: ...card Replace SD memory card OR Synchronize the Masterdock date time using the Masterdock Utility LEDs indicate normal operation Green however unable to perform a Bump Test or Calibration Empty calibra...

Page 29: ...duce time spent on repairs the SCOTT Instruments Service Department requires a Return Maintenance Authorization number be issued prior to any product being shipped for service repairs Contact the Serv...

Page 30: ...Health Safety Monroe Corporate Center PO Box 569 Monroe NC 28111 Telephone 1 800 247 7257 FAX 704 291 8330 www scotthealthsafety com Printed in the USA Copyright 2010 SCOTT All Rights Reserved...

Reviews: