CHAPTER 4: OPERATION
087-0067 REV A
SCOTT SAFETY
Model depending, either refer to the LCD or the control panel on the charge station.
These instructions are based on a control panel interface.
Figure 34
Cylinder Charging Controls
4
When system pressure is adequate to fill the breathing air cylinders, unlock the fill
station door by operating the handle (item 1) on the right side of the chamber
(Yellow lock bars not showing). See
.
Table 24
Cylinder Charging Controls
REFERENCE
NUMBER
ITEM
1
SCBA Fill Pressure Analog Gauge - Indicates the SCBA pressure.
2
Manual Air Flow On/Off Knob - Allows air pressure from the storage to the
SCBA cylinder.
3
Pressure Regulator - Controls the pressure output to the SCBA. For use
only by service technician.
4
Compressor Pressure Analog Gauge - Indicates the compressor pressure.
5
Storage Pressure Analog Gauge - Indicates the storage pressure.
6
Schrader Valve - To calibrate CO.
7
Schrader Valve - To take sample of air.
8
Dual Pressure Toggle Switch - Selects between the two pressures.
1
2
3
4
5
6
7
8
Summary of Contents for HushAir Connect 7500
Page 1: ...User Guide 087 0067 Rev A HushAir Connect 7500 COMPRESSOR SYSTEM ...
Page 2: ......
Page 3: ...HushAir Connect 7500 User Guide COMPRESSOR SYSTEM 087 0067 Rev A ...
Page 8: ...IV CONTENTS 087 0067 REV A SCOTT SAFETY ...
Page 12: ...X LIST OF TABLES 087 0067 REV A SCOTT SAFETY ...
Page 42: ...20 CHAPTER 2 INSTALLATION 087 0067 REV A SCOTT SAFETY ...
Page 73: ...Configuring the System 51 SCOTT SAFETY 087 0067 REV A Figure 27 Override Status Screen ...
Page 106: ...84 CHAPTER 5 MAINTENANCE 087 0067 REV A SCOTT SAFETY Figure 48 Oil Drain Location 3 1 2 ...
Page 112: ...90 APPENDIX A SPECIFICATIONS 087 0067 REV A SCOTT SAFETY ...
Page 119: ......