Refrigeration Line Set Installation
Details of Quick Connect Coupling Assembly
Male Fitting Before Connecting
Male Fitting After Connecting
Quick connect coupling assembly can be as simple as tightening a nut. But if
not done properly, an expensive, not-covered-by-warranty refrigerant leak
will occur. This booklet lists correct assembly steps, shows results of partial
assembly and describes how a leak proof joint is made.
Summary of Contents for Ice Machine none
Page 4: ...Page 4 Coupling Assembly Details Two Threads Showing Barely Pierced Knives Just Showing...
Page 5: ...Page 5 Coupling Assembly Details One Thread Showing Knives Exposed Partly Pierced...
Page 6: ...Page 6 Coupling Assembly Details Threads Flush Knives Visible Pierced but will leak...
Page 7: ...Page 7 Coupling Assembly Details Correctly Tightened Fully Open Fully Open...