NME1854R & FME2404R
January 2000
Page 22
1. The bin control uses devices that sense light,
therefore they must be kept clean enough so that
they can “see”. At least twice a year, remove the
bin control sensors from the base of the ice chute,
and wipe the inside clean, as illustrated.
2. The ice machine senses water level by a probe
located in the water reservoir. At least twice a
year, the probe should be removed from the
reservoir, and the tip wiped clean of mineral
build-up.
SENSOR MAINTENANCE
These units consist of
two separate
Ice Machines; to properly clean and maintain the them, these steps
must be followed for
both
systems.
ICE DISCHARGE
CHUTE
SLIDE IN AND
OUT
ICE LEVEL
SENSORS
Clean the Probe's Tip with ice
machine cleaner and a clean,
soft cloth.
3. Clean the air cooled remote condenser coil when
it becomes restricted.