WATER RESERVOIR
1. Shut off the water supply to the icemaker.
2. Remove front panel and reservoir cover.
3. To remove float only, "A" models: pry the
mounting flanges apart enough to lift one float
pivot pin out of the flange hole, and pull float up
and out of the reservoir. "B" models: disconnect
water inlet tube, push in the tab behind the
reservoir and pull valve assembly out of the
reservoir tank.
4. To remove reservoir, disconnect water inlet
compression fitting at reservoir inlet.
5. Remove drain hose from reservoir.
6. Remove evaporator inlet hose from reservoir.
7. Remove mounting screws from reservoir
bracket, and remove reservoir from icemaker.
8. Reverse to reassemble.
BIN CONTROLS (Ice Level Sensors)
1. Disconnect electrical power.
2. Remove front panel.
3. Remove control box cover.
4. Locate ice chute, at the base of the chute, in
front of and behind it are two plastic bin control
mounts.
5. Slide each bin control to the left, and in the
control box, disconnect the electrical leads
connecting the bin control to the circuit board.
6. Reverse to reassemble, be certain that the bin
controls are aligned so that the ice level sensors
are visible (centered) through the holes in the cube
chute.
FLOAT
ASSEMBLY
FLOAT
MOUNTING
FLANGES
CHUTE
SLIDE BIN
CONTROLS
IN AND OUT
REMOVAL AND REPLACEMENT
Float Valve
Internal
Plunger
B Model
A Model
FM2400RH
August 1994
Page 20