37
/57
7.1
QUICKTUNE
QuickTune
software was developed especially for
NOVUS
controllers and indicators. With a user-friendly and practical interface, it
facilitates device configuration and management, and communicates through USB, Bluetooth, and RS485 interfaces (in this case, with the
ClickNGo
CG-485
module) or through a TCP/IP connection.
This manual describes the functionalities related to the device configuration. For more information, check the specific operations manual.
The software can be downloaded free of charge from our website
, in the Download Area.
7.2
QUICKTUNE MOBILE
QuickTune Mobile
is the ideal tool to daily access your
N20K48 Modular Controller
. Available for Android and iOS smartphones, it
allows you to configure or monitor your device. Connection to the device can be made via the Bluetooth interface.
QuickTune Mobile
can be downloaded for free from the Google Play Store or the Apple Store. Once the application has been installed,
you must enable the Bluetooth interface of the smartphone to connect it to the device. For more information about how to enable the
Bluetooth interface of the
N20K48 Modular Controller
, see
section of this manual.
If your smartphone does not support BLE technology, has an Android version less than 6.0, or an iOS version less than 11, the
application will not be available for download.
QuickTune Mobile
uses the native iOS "Files" app for file management.
7.3
CONFIGURING THE DEVICE WITH QUICKTUNE
You can configure your
N20K48 Modular Controller
by clicking the
Read Device
button, located on the
QuickTune
software home
screen (Windows) and the
QuickTune Mobile
app home screen (Android or iOS).
The following sections describe each of the configurable parameters.
7.3.1
BASIC
This screen allows you to configure the main parameters of the controller:
QuickTu
ne
QuickTune Mobile
Basic tab
•
Temperature Unit:
Allows you to define the temperature unit to be used: “Celsius” or “Fahrenheit”.
•
Control Mode:
Allows you to define the control mode of the device: “Manual” or “Automatic” (see
section).
•
Enables control and controller outputs:
Allows you to enable control and outputs.
•
Sensor type of the main input:
Allows you to define the sensor type of the main input (see
section).
•
Lower limit of SP:
Allows you to define the lower limit for the Setpoint adjustment. Allows you to define the minimum value of the
PV indication range and limit the SP adjustment of the available
linear analog signal inputs
(0-20 mA, 4-20 mA, 0-50 mV, 0-5 V
and 0-10 V).
•
Upper limit of SP:
Allows you to define the upper limit for the Setpoint adjustment. Allows you to define the maximum value of the
PV indication range and limit the SP adjustment of the available
linear analog signal inputs
(0-20 mA, 4-20 mA, 0-50 mV, 0-5 V
and 0-10 V).
•
Control Setpoint:
Allows you to define the control setpoint, according to the minimum and maximum limits of the configured SP.
•
OUT.A Function:
Allows you to define
out.A
output function: “Off”, “Control Output 1”, “Control Output 2”, “Alarm 1”, “Alarm 2”,
“Alarm 3”, “Alarm 4”, “Timer 1”, “Timer 2” or “Modbus-Coil” (see
section).
7