These hotplates are general purpose hotplates that are robustly con-

structed and designed for continual usage. All Models are controlled 

by an energy regulator which varies the power input to the elements 

enabling finer control at lower surface temperature. There is no sur-

face temperature indication.

PRODUCT DESCRIPTION 

THESE INSTRUCTIONS MUST BE FOLLOWED FOR US TO 

GUARANTEE OUR FULL SUPPORT OF YOUR CLAIM FOR 

PROTECTING AGAINST LOSS FROM CONCEALED DAMAGE. 

THE FORM FOR FILING SUCH A CLAIM WILL BE PROVIDED 

BY THE CARRIER.

UNPACKING 

Unpack the product and check for any damage incurred during 

transit. This should be reported to the responsible carrier, railway or 

postal authority, and a request for a damage report should be made.

1.  Ensure that the unit is placed on a sturdy bench. 
2.  Install the unit away from combustible material and preferably 

at least 300mm away from the wall or adjacent surfaces.

3.  Check that the mains voltage complies with the rated 
      220-240VAC 50Hz-15 amp supply voltage and plug into power 

socket.

4.  To energize the heating elements turn the energy regulator 

knob marked 0 to 6 to the desired setting.

5.  The hotplate element will cycle on and off at the setting 

selected.

6.  To have the heating elements permanently energized, the knob 

should be turned to position 6.

7.  The hotplate top is covered with a special heat resistant 

coating which may smoke initially as the unit is burned in.  
This is normal.

GENERAL INSTALLATION AND OPERATION INFORMATION

Part

No.

1

502 TOP PLATE

2

ELEMENT 1500W 230V

3

ELEMENT CLAMP

4

TERMINAL BLOCK

5

POWER CORD

6

CABLE GRIP

7

ENERGY REGULATOR

8

CONTROL PANEL

9

KNOB

10

CONTROL PANEL INSERT

11

PILOT LIGHT

12

BOTTOM COVER

13

LARGE RUBBER FOOT

14

BODY ASSEMBLY

15

ELEMENT COVER

Description 

MODEL : LABORATORY HOTPLATE

MODEL CODE : 502

1

14

Summary of Contents for 500 R00

Page 1: ...RECEIVE YOUR FULL TWO YEAR WARRANTY MANUFACTURED IN SOUTH AFRICA www scientific co za All Scientific equipment comes with a standard ONE year warranty The 1 Year Extended Warranty is only valid for customers who have registered their warranty online at www scientific co za within the first year after making their purchase WARRANTY ...

Page 2: ...roduct Code see box label Serial number see back of machine ONLY COMPLETE IF YOU DO NOT HAVE WEB ACCESS INTENDED USE Agriculture Automotive Biochemistry Botony Chemistry Cosmetics Electronics Food Genetics Industrial Medical Microbiology Mining Nuclear Paper Packaging Petrochemical Pharmaceutical Physics Power Generation Special Metals Sugar Water Zoology Other Specify ALL SCIENTIFIC EQUIPMENT COM...

Page 3: ...thorized dealer All other Warranties expressed or implied statutory or otherwise in cluding without limitations any implied Warranty of Merchantability or fitness for purpose are excluded The Seller shall in no event be liable for direct indirect or consequential damages in connection with the products This unit is at all times to be used according to the instruction manual and for its normal purp...

Page 4: ... the unit away from combustible material and preferably at least 300mm away from the wall or adjacent surfaces 3 Check that the mains voltage complies with the rated 220 240VAC 50Hz 15 amp supply voltage and plug into power socket 4 To energize the heating elements turn the energy regulator knob marked 0 to 6 to the desired setting 5 The hotplate element will cycle on and off at the setting select...

Page 5: ...CONTAINING ABRASIVE SUBSTANCES DRY CARE FULLY AFTER CLEANING DO NOT USE PRODUCTS CONTAINING AGGRESSIVE CHEMICALS ACIDS OR PRODUCTS WITH CHLORINE CLEANING Care should be taken when operating this appliance as hot surfaces are present which may cause burns Ensure that the power supply cord does not come into contact with hot surfaces It is recommended not to leave the unit in operation unattended EX...

Page 6: ...at level position 8 Do not operate if equipment has been damaged or is malfunc tioning in any way 9 These units are designed to run only on alternating current A C DO NOT CONNECT TO DIRECT CURRENT D C WARNING Electric Shock Hazard Keep water and other liquids from entering the inside of the equipment Liquid inside the equipment could cause an electrical shock Do not spray water or cleaning product...

Page 7: ...POSITIONING DIAGRAM LABORATORY HOT PLATE MODELS 500 501 502 B A C MODEL A B C 500 300 136 305 501 450 136 305 502 600 136 455 EXPLODED DIAGRAM LABORATORY HOT PLATES MODELS 501 4 11 ...

Page 8: ... SERVICE PERSONNEL ONLY MODEL DESCRIPTION VOLTS V Hz POWER WATTS 500 HOTPLATE 300mm 230 50 1500 501 HOTPLATE 450mm 230 50 2000 502 HOTPLATE 600mm 230 50 3000 Part No 1 BODY ASSEMBLY 2 ELEMENT COVER 3 TERMINAL BLOCK 4 CABLE GRIP 5 POWER CORD 6 ELEMENT 7 TOP PLATE 8 ELEMENT CLAMP 9 230V ENEEGY REGULATOR 10 CONTROL PANEL FACIA 11 INSERT 12 PILOT LIGHT 13 CONTROL KNOB 14 BOTTOM COVER 15 LARGE RUBBER F...

Page 9: ...EXPLODED DIAGRAM LABORATORY HOT PLATES MODELS 500 230V L N E E1 4 2 S2 P1 P2 S1 ER H1 WIRING DIAGRAM MODEL LABORATORY HOT PLATE MODEL CODES 500 501 6 9 ...

Page 10: ...TE MODEL CODES 502 LEGEND DESCRIPTION PART NUMBER ER ENERGY REGULATOR 1 ER URS0012 H1 HEAT CONTROL PILOT LIGHT 1 PL GP E1 E2 ELEMENT 1500W 230V 5 2000W M GRILL WIRING DIAGRAM LEGEND MODEL LABORATORY HOT PLATE MODEL CODES 501 LEGEND DESCRIPTION PART NUMBER ER ENERGY REGULATOR 1 ER URS0012 H1 HEAT CONTROL PILOT LIGHT 1 PL GP E1 ELEMENT 1500W 230V 5 1500W 500 WIRING DIAGRAM MODEL LABORATORY HOT PLATE...

Reviews: