Unwrapped Cycle 

Sterilize light loads of solid metal instruments  

such as hand instruments, speculums and  

forceps.

2000 G4: 

This is NOT a sterilization cycle. Refer to 

Operator’s Manual. 

5000 G4: 

Sterilize larger loads of unwrapped metal 

instruments.

Drying PerformanCe

  

four steps to obtaining optimal drying results

After cleaning and drying the  
cassette, treat the interior  
surfaces with STAT-DRI

 Plus. 

Coat Cassette

Use Drying Plate rack   

(5000 only)

For optimal drying performance of wrapped 
instruments, use the drying plate rack  
supplied and insert one bag per plate  
with window side up. 

Set Up Waste Bottle 

Fill this bottle with water to 
the minimum level and set it 
on, or close to the floor.

Plate positions 

for full load  

(10 bags).

With thumbs on the thumb  
pads, push down, pulling up 
with forefingers until lid opens.

opening / Closing  

the Cassette

®

Hold the cassette handle in one 
hand and the carry handle in the 
other. Place the end of the cassette 
into the unit and drop the carry 
handle into its closed position.

inserting Cassette

filling Cassette

 

5000 model

2000 model

5000 model

Gently push cassette inward until 
you hear a click. Never force the 
cassette into the STATim.

2000 and 5000 models

Cycle Starting guide

1

2

3

4

1. 

2. Scroll to    Level     and select.

3.  Adjust the leveler  

feet to move the  
bubble. Level  
will change from  
red to green.

Levelling your Unit

• 

Replace water as needed.  

• 

 For ophthalmic use, drain at the 
end of every workday, leave empty, 
and refill at the start of the next 
workday. 

• 

 Empty the waste bottle every time 
you refill the water reservoir.

• 

 Fill the bottle with water, up to the 
MIN line marking. You may also add 
some chlorine-free disinfectant.

•  

Wash the interior of the cassette with dishwashing soap or a 
mild detergent that does not contain chlorine. 

•  

 Scrub the inside with a cleaning pad designed for use with 
Teflon

®

-coated surfaces. 

•  

After removing all traces of the detergent, treat interior sur-
faces of the cassette with the STAT-DRI

 Plus drying agent to 

enhance drying process. Additional STAT-DRI

 Plus can be 

ordered by requesting 2OZPLUS, 8OZPLUST, or 32OZPL US.

•  

Check the water reservoir filter every week and clean  
if necessary. Replace only if necessary. 

•  

Replace every 500 cycles or  
six months (whichever is first).  
Call for service if wet. 

• 

 Replace every 500 cycles or  
six months (whichever is first). 

•  

Replace every 500 cycles or  
six months (whichever is first),  
or whenever necessary.

Cassette

 
 
 
 
 
 

Water Reservoir 

Filter 

 

Biological Filter 

 

 

Air Filter

 

 

Cassette  Seal   

Water 

Reservoir

 

Waste 

Bottle

toUCh SCreen menU oPtionS

network Connectivity –  
Indicates you are connected to  
the network.

USB Storage Device –  
Access last 5 cycle data and  
last 5 cycle faults. Indicator also 
confirms proper USB connection.

Water Level / Quality Status** – 
Indicator will notify user if water  
is of sufficient quality or quantity  
to proceed with sterilization.

Cassette Status** – Indicator  
will notify user if cassette has  
been properly inserted.

User/technician menu – Access 
unit information and menus to 
change unit settings.

Start Button – Button is 
enabled once a cycle type has 
been selected and used to begin  
a cycle.

StoP Button – Button is enabled 
after a cycle has started and used 
to interrupt a cycle.

Toggle 

UP/DoWn to  

view menu options.

enter 
Push button to view/select 
menu options.

BaCK 
Push button to return  
to previous menu.

Wrapped Cycle

Sterilize solid or hollow metal instruments which 

have been sealed in autoclave bags. 

rubber and Plastics Cycle

air Dry only Cycle (2000 g4) 
heavy Duty Unwrapped Cycle (5000 g4)

Sterilize solid or hollow unwrapped instruments.

  DaiLy

Do not overload cassette.   

StatIM

      

generaL USage 

Operator’s Manual should be consulted before using this autoclave

**  NOTE: Sterilization cycle will not begin if there is an error

USer/teChniCian   

menU anD navigation

generaL maintenanCe

  

to ensure trouble-free performance, follow this preventative maintenance schedule.

  WeeKLy

   every 6 monthS

www.

scican

.com

STATim is a registered trademark and STAT-DRI, Dri-Tec

R

 and Dri-Tec

C

 are trademarks of SciCan Ltd. Teflon is a registered trademark of E.I. Du Pont de Nemours and Company Corporation.

95-112742 Rev. 2.0

Best Practices: SciCan recommends the final user carefully 
choose the most appropriate sterilization cycle according  
to the recommendations of their leading infection control 
authorities and local regulatory guidelines / recommendations.

09-110755 Rev1: Artwork, Dri-Tec-C
Designed:  March 11, 2008

PANTONE 363 C

BLACK

TEXT FONTS:
Dri-Tec: Frutiger Bold
STEAM HEAT DRYING: Copperplate Bold

20% Black
Outline around Dri-Tec

09-110757 Rev1: Artwork, Dri-Tec-R
Designed:  March 11, 2008

PANTONE 280 C

20% Black
Outline around Dri-Tec

BLACK

TEXT FONTS:
Dri-Tec: Frutiger Bold
STEAM HEAT DRYING: Copperplate Bold

2000 and 

5000 models

2000 model

5000 

model

4

8

4

8

4

1

2

3

4

1

2

3

4

1

2

3

4

4

Reviews: