FEATURES:

Large Tank Capacity

Tank capacity 6.0 L / 1.6 gallon.
Tank size:  32.5 x 20.5 x 9.9 cm / 12.7” x 8.1” x 3.9”

Large Tank Capacity

Patented design, basket can be raised and suspended to 

drain water. 

Control panel with capacitive 
sensing technology

Solid panel top. Durable, reliable, resistant to water and 

harsh chemicals.

Drainage valve 

Convenient to use. 

Two industrial grade 
ultrasonic transducers

Uniform distribution of ultrasonic waves, strong cleaning, 

high durability.

Two ceramic heaters

Mounted underneath the bottom of the tank for safe and 

even heating; more durable construction. 

3-color LED display

1 to 30-minute full range timer, 5 temperature settings, actual 

temperature thermometer, degas and solution usage timer. 

Independent control circuit
for each ultrasonic transducer

40% higher cleaning efficiency, not susceptible to 

interference, more durable.

Multiple circuit protectors

When overloaded or improperly used, the protectors shut 

down the power to certain areas to protect the machine.

Moisture-proofed PCB with 
industrial IC

Capable for different working environments with better anti-

interference performance.

Two cooling fans

One for cooling of PCB boards, one for cooling of ultrasonic 

transducers. Improve heat dissipation and beneficial for 

continuous operations.

Multiple optional accessories

Suspendible plastic basket, stainless steel rack and tray, 

indirect cleaning tank, beaker and double beaker holder.

Solid and advanced structural 

design

4.5 mm thick wall housing made from engineering grade 

plastic with tongue-in-groove design for better waterproof 

and drop-proof performance. 

SD-485 US EN R1_StatClean user manual.indd   1

2016-06-09   12:58 PM

Summary of Contents for StatClean

Page 1: ...usage timer Independent control circuit for each ultrasonic transducer 40 higher cleaning efficiency not susceptible to interference more durable Multiple circuit protectors When overloaded or imprope...

Page 2: ...ith capacitive sensing technology Durable reliable resistant to water and harsh chemicals Advanced power off memory that recalls last timer and temperature settings Electrical circuit features 1 Two s...

Page 3: ...SSORIES 6 CONTROL PANEL AND OPERATIONS 7 OPERATION GUIDELINES 9 MEMORY OPERATIONS 11 COMMON CLEANING METHODS 12 PRODUCT EXPLODED VIEW 14 CARE AND MAINTENANCE 16 OPTIONAL ACCESSORIES 17 SPECIFICATIONS...

Page 4: ...e do not cause it to get caught by things such as a cupboard door or a chair leg do not drag across a hot surface If there is damage to the power plug cord housing or other parts of the device do not...

Page 5: ...using the appliance To reduce the risk of injury close supervision is necessary when an appliance is used near children Only use attachments recommended or sold by the manufacturer Do not use outdoor...

Page 6: ...Indicator 5 Solution Usage Remaining Time 6 Solution Warning Light 7 Degas Status 8 Normal Cleaning Status 9 Heater Status 10 Working Status 11 Heater Key 12 Funtion Key 13 On Off Key 14 Decreasing Ke...

Page 7: ...bubbles on the tank walls These will reduce the cleaning effect in the beginning phase of ultrasonic cleaning Turning on the degas function will dissipate the droplets and the air bubbles usually in...

Page 8: ...d pressing the button each time reduces the timer buy 1 minute b When Temp is used pressing the button each time reduces the set temp down to the next level c When h min is used pressing the button ea...

Page 9: ...evel The digital timer will count down to show the remaining cleaning time When it displays 00 00 the cleaning cycle stops To stop cleaning at any time press On Off button twice The unit is equipped w...

Page 10: ...running for 50 minutes OPERATION GUIDELINES When cleaning is completed switch off the power open the lid and retrieve the basket and the items Alternatively raise and suspend the basket above water a...

Page 11: ...g cycle is started It will not stay if the power is turned off f If the On Off key is touched twice during the cleaning cycle the cycle will stop and the timer setting will stop running It ll resume t...

Page 12: ...s Basket can reduce the friction between the items and the tank 2 During cleaning dirt will come off like a cloud and the water will become murky over time When the cloud stops coming the cleaning is...

Page 13: ...ned off automatically after 50 minutes D Special cleaning Silver copper or brass items with oxidation which has darkened the items will need special cleaning Cleaning Method 1 Put the items in the bas...

Page 14: ...14 PRODUCT EXPLODED VIEW SD 485 US EN R1_StatClean user manual indd 14 2016 06 09 12 58 PM...

Page 15: ...Spout ABS 23 Ball valve Standard part 24 Bracket ABS 25 Elbow ABS 26 Valve handle ABS 27 Bottom cover ABS 28 Power PCB 1 94V0 29 Power PCB 2 94V0 30 Cooling fan Standard part 31 Right handle ABS 32 R...

Page 16: ...e heater from running hence to prevent damages to the unit and fire hazard The switch cuts off power for approximately 6 10 minutes then reconnect the power automatically Do not run the unit for exten...

Page 17: ...r to drain water Place the beaker holder with beaker s across the top of the main cleaning tank as shown Add water to the main tank so the water level reaches the beaker s Add solution inside the beak...

Page 18: ...P4862 Tank Capacity 6 0 L 1 6 gallon US Max 5 0 L 1 3 gallon US Min 3 35 L 0 9 gallon US Tank Size 32 3 x 20 5 x 9 9 cm 12 7 x 8 1 x 3 9 Longest Item Fits inside Tank 34 0 cm 13 4 Power Supply 260 W...

Reviews: