33
TROUBLESHOOTING
Condition/Problem
Things to Check
Solution
No display/partial display/
unit will not turn on
Check electrical (wall)
outlet
Make sure unit is plugged into a functioning wall outlet.
Check connection on
console
Connection should be secure and undamaged. Replace adapter
or connection at unit if either are damaged.
Check data cable integrity
All wires in cable should be intact. If any are visibly crimped or
cut, replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly. Small
latch on connector should line up and snap into place.
Check console display for
damage
Check for visual sign that console display is cracked or otherwise
damaged. Replace Console if damaged.
Console Display
If Console only has partial display and all connections are fine,
replace the Console.
If the above steps do not resolve the problem, contact your local
distributor for further assistance.
Unit operates but Contact
HR not displayed
HR cable connection at
Console
Be sure cable is connected securely to Console.
Sensor grip
Be sure hands are centered on HR sensors. Hands must be kept
still with relatively equal pressure applied to each side.
Dry or calloused hands
Sensors may have difficulty with dried out or calloused hands.
A conductive electrode cream (heart rate cream) can help make
better conduct. These are available on the web or at medical or
some larger fitness stores.
Handlebar
If tests reveal no other issues, Handlebars should be replaced.
Console displays “E2” error
code
Check data cable integrity
All wires in cable should be intact. If any are cut or crimped,
replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly. Small
latch on connector should line up and snap into place.
Console Electronics
If tests reveal no other issues, contact your local distributor for
further assistance.
No speed/RPM reading,
Console displays “Please
Pedal” error code
Check data cable integrity
All wires in cable should be intact. If any are cut or crimped,
replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly. Small
latch on connector should line up and snap into place.
Check magnet position
(requires shroud removal)
Magnet should be in place on pulley.
Check Speed Sensor
(requires shroud removal)
Speed sensor should be aligned with magnet and connected to
data cable. Realign sensor if necessary. Replace if there is any
damage to the sensor or the connecting wire.
Console shuts off (enters
sleep mode) while in use
Check electrical (wall)
outlet
Make sure unit is plugged into a functioning wall outlet.
Check connection on
console
Connection should be secure and undamaged. Replace adapter
or connection at unit if either are damaged.
Check data cable integrity
All wires in the cable should be intact. If any are cut or crimped,
replace cable.
Summary of Contents for 130i Upright Bike
Page 35: ...35...
Page 36: ...Nautilus Bowflex Schwinn Universal 8002952 100114 B EN...