USER MANUAL ZHS03
WIRELESS DUAL PADDLE
WALL SWITCH
ZHS03
MANUFACTURER INFORMATION
Dear Customer,
should you require technical advice and your
retailer could not help please contact our
technical support.
Schwaiger GmbH
Würzburger Straße 17 90579 Langenzenn
Hotline: +49 (0) 9101 702-199
www.schwaiger.de [email protected]
BDA_ZHS03_b
Business hours:
Monday to Thursday:
08:00 - 17:00
Friday:
08:00 - 14:30
HOME AUTOMATION
Congratulations and thank you for purchasing the Schwaiger ZHS03 pro-
duct. Below you will find useful operating guidelines.
Product description
Not only can both Z-Wave devices be controlled directly with the Z-Wave.Me wireless wall switch, but
in an IP gateway different scenes can be activated. Although the wireless wall switch controls devices
directly, it cannot as Z-Wave controller manage their networks but always requires an additional con-
troller for inclusion and exclusion. The device can operate in different modes, which are determined
by configuration parameters:
1.
Control groups of other Z-Wave devices with „ON“, „OFF“ and dimming commands.
2.
Control of devices in the vicinity of the fob with „ALL ON“ or „ALL OFF“ - commands.
3.
Activation of pre-defined scenes in gateways or other Z-Wave devices.
Installation guidelines
The device is delivered in working condition with a built-in battery. In this default condition simply
pressing on one of the buttons - since the device is not included in a network and therefore unable
to send a message - will result in an error code (flashing red LED). In this manner the operational
readiness of the device can be tested.
The device distinguishes between two operating modes: standard and
management mode
Standard mode:
In this mode, the wireless wall switch can control other devices or activate scenes.
Management mode:
The device is switched to management mode when all four buttons are held down together for at least
5 seconds. A slow flashing green LED confirms the management mode. In management mode the
buttons have other functions. Without further button operation, the unit will return to standard mode
in 10 seconds. Each operation also ends the management mode.
In management mode the following actions can be performed:
Button 1
Network-wide inclusion: the device can be added to a Z-Wave network from anywhere in the network.
This requires a primary controller that supports explorer frames. This mode lasts 20 seconds and stops
automatically. Touching any key also stops the mode.
Button 2
Sends node information frame and wake-up messages (as outlined in the following chapters).
Button 3
Standard inclusion/exclusion mode: the device is directed by a controller of direct wireless range.
Touching any button stops the mode. An exclusion of the device from a network resets the device to
its factory defaults.
Button 4
Set associations: to assign target devices to one of the 4 association groups
Batteries
This device is battery-operated. Use only batteries of the specified type.
Used batteries contain hazardous substances and must not be disposed of with household waste!
Battery type: 1 x CR2032
Performance of the device in the Z-Wave network
When delivered the device is not connected to a Z-Wave network. It must be integrated into a Z-Wave
network so that it can communicate with other Z-Wave devices. This process is called Z-Wave inclu-
sion. Devices can also be removed from networks again. This process is called Z-Wave exclusion.
Both processes are started from a controller that must be connected to an inclusion and/or exclusion
mode. The manual of the controller contains information on how it is to be connected in these modes.
Devices can only be added when the controller of the Z-Wave network is in inclusion mode. Leaving
the network through exclusion will reset this device to its factory defaults.
Bring your Z-Wave controller in the inclusion mode. Bring your wireless wall switch in management
mode and press button 3. The device is included and/or excluded locally by pressing key 3 in man-
agement mode. In order to include and/or exclude the device network-wide button 1 in management
mode must be pressed.
Confirm
network-
wide
inclusion
Confirm
normal inclu-
sion
Node information
frame
Wake-up
Information
Start
association
mode
1
2
3
4
LED
Batterie
Group 1/2
ON
Group 1/2
OFF
Group 3/4
ON
Group 3/4
OFF
1
2
3
4
LED
Batterie
Operation of the device
Depending on the mode and further configuration the device can be set differently.
Standard mode:
Controlling a group with 2 buttons (This is the default setting). One group (no. 1) of the equipment
is controlled with buttons 1 and 3; the other group (no. 2) is controlled with buttons 2 and 4. Buttons 1
and 2 switch the actuators „ON,“ buttons 3 and 4 switch the actuators „OFF.“ If double-click the setting
parameters #1 or #2 is activated, groups 3 and 4 can be controlled by means of short double clicking.
Dimming of devices is enabled through pressing the buttons for a long time (high-dimming with
buttons 1 and 2, low-dimming with buttons 3 and 4) and/or a short click and pressing for groups
with a double click.
A single click controls groups 1 and 3
A double click controls groups 2 and 4
The device can be mounted on every level and dry sur-
face, either with screws or double-sided tape. First the
base plate is secured to the wall. In the next step, the
switching element is secured to the frame. The electron-
ics module is used to fix the frame to the base plate,
as shown in the figure. Finally, the rocker switches are
mounted on the electronics module.
For a battery change the rocker switches must be re-
moved. The CR battery can be replaced by pressing the
small locking tab above the battery.
Logging in (inclusion) or logging out
(exclusion) of the sensor.
The device operates in normal control mode or in man-
agement mode. Pushing all four buttons for 5 sec. will
turn the device into management mode (indicated by
blinking green LED). The management mode will time
out after 10 seconds if no further button is pushed.
Button 1 confirms standard inclusion or exclusion
started by a primary controller, button 2 issues a Node
Information Frame or wakeup notification, button 4 is
used to add devices into association groups and button
1 confirms inclusion or exclusion in NWI (network wide
inclusion) mode.