![SCHUNK VERO-S NSL3 Assembly And Operating Manual Download Page 28](http://html1.mh-extra.com/html/schunk/vero-s-nsl3/vero-s-nsl3_assembly-and-operating-manual_1215842028.webp)
Assembly
28
03.00 | NSL3 | VERO-S quick-change pallet system | en | 1155408
4.3.7 NSL3 800
The clamping station can be clamped directly onto the machine
table via screws. Permitted areas for appropriate bore holes can
be found in the attached bore hole drawings. Optionally, BRR 50
clamp banks can be purchased. There are already 6 mounting
holes at a distance of 200 x 200. The mounting points are located
in the middle between the clamping modules. Size M10 screws can
be used at the additional mounting points to achieve more rigid
set-up on the machine table when using clamps. There are two
alignment grooves on the bottom of the clamping station to
mount T-nuts used for aligning the clamping stations on the
machine table. These allow for precise alignment along an
alignment groove. The NSL3 800 is equipped with two
interconnected G 1/8" air connections for simultaneously
unlocking all eight clamping points. The air supply can be
connected to either the front or the back of the clamping station.
The opposing connection point is closed with a locking screw.
Supply occurs either via a pneumatic plug connection G1/8" 8/6 or
a sealing nipple for locking couplings type NW 7.4 (accessory). The
clamping station can be retrofitted at the connection points using
a separately available connecting strip (accessory).