![SCHUNK VERO-S NSE-A3 138 Assembly And Operating Manual Download Page 25](http://html1.mh-extra.com/html/schunk/vero-s-nse-a3-138/vero-s-nse-a3-138_assembly-and-operating-manual_1215838025.webp)
Assembly
02.00|1376941_NSE-A3 |en
25
Number of modules
At least nominal hose width
1
4 mm
2, 3, 4
6 mm
from 5
8 mm
When disconnecting hose lines, the relevant openings of the air
supply connections must be protected with seal plugs or sealing
caps to prevent the ingress of dirt or coolant.
Removal from the installation space
Detachable threads facilitate removal of the modules from the
installation space of the clamping stations. To pull off the clamping
module out of the installation space, two levering tools (e.g. long
cylindrical screws) are screwed diagonally into the two available
internal threads of the mounting holes.
Mounting
Mounting in the installation space is with 6 M8 screws for the
version without torque pin V4, or with 5 M8 screws and a fitting
screw for the version with torque pin V4.
The assembly module can be positioned by means of two
centering diameters of the installation space:
Ø 110 H6
in the lower range. For partial and full installation.
Ø 138 H6
in the upper range.
Position orientation for modules with torque pin V4 is achieved
with a fitting screw with a diameter of Ø 9 f7 x 5 mm. In order to
do this, make a Ø9 H7 hole at a distance of 60.5 +/- 0.01 mm from
the axis of the centering diameter (Ø110 H6 / Ø138 H6) on the
mounting bolt circle.
The air connection is via the bottom coupling holes in the unit as
standard.
4.3.1
Summary of Contents for VERO-S NSE-A3 138
Page 26: ...Assembly 26 02 00 1376941_NSE A3 en ...
Page 29: ...Assembly 02 00 1376941_NSE A3 en 29 Usage arrangement of the different types of clamping pins ...
Page 46: ...Assembly Drawings 46 02 00 1376941_NSE A3 en Assembly Drawings Assembly 10 10 1 ...
Page 47: ...Assembly Drawings 02 00 1376941_NSE A3 en 47 Cone seal KVS3 138 10 2 ...