4.2.2 Sensorposition
Terminal block (max, 100Ncm)
Switching lug
Cover
Counter nut (secures cylindrical screw)
Cylindrical screw to adjust the query position
PG fitting (Ø16; projection over housing floor 5mm)
Proximity switch cable outlet
Proximity switch
The inductive proximity switch IN 80-S is installed.
Adjusting the query position:
• Turn the cylinder head screw clockwise: the switching flag
moves into direction of the screw head
• Turn the cylinder head screw counter clockwise: the switching
flag moves away from the screw head