Maintenance and care
36
01.00 | | TOOLFIX modular tool mounting device | en | 1510829
8.4 TOOLFIX MONO or VARIO tool adapter – HSK ( E+F )
Monthly: Visual inspection and cleaning of the quick-change
interface (1)
Clean and inspect the quick-change interface (1) of the tool
adapter. In case of damage or heavy wear, the interface must be
replaced (only necessary for adapters of the VARIO series).
Monthly: Cleaning and visual inspection of the toolholder
mounting interface (2)
Clean and inspect the toolholder mounting interface. In case of
damage or heavy wear, the tool adapter must be replaced.
Monthly: Functional check of the tool locking mechanism (3)
Turn the tool locking mechanism counterclockwise until the two
internal chuck jaws are completely retracted into the base body of
the tool adapter. Then turn the locking mechanism clockwise until
the jaws have moved to the inner end position. The hand lever of
the locking mechanism must move smoothly during the complete
clamping stroke. Perform a test clamping with an HSK form E or F
toolholder.