Troubleshooting
03.00 | TCU-P | Assembly and Operating Manual | en | 389462
23
5 Troubleshooting
5.1 Product is not moving
Possible cause
Corrective action
Incorrect air supply.
Check air supply.
5.2 Product does not lock itself?
Possible cause
Corrective action
Proximity switch defective or set incorrect.
Disassemble and clean the product.
Pressure drops below minimum.
Readjust or change sensor.
5.3 Product does not execute the full stroke for the locking?
Possible cause
Corrective action
Dirt between cylinder and cylinder cover.
Disassemble and clean the product.
Pressure drops below minimum.
Check air supply.,
5.4 Locking force decreases during locking
Possible cause
Corrective action
Compressed air can escape.
Check seals, if necessary, disassemble the
product and replace seals.
To much grease in the mechanical
movement space.
Clean and lubricate product.
Pressure drops below minimum.
Check air supply.