![SCHUNK TANDEM KSP3 Assembly And Operating Manual Download Page 23](http://html1.mh-extra.com/html/schunk/tandem-ksp3/tandem-ksp3_assembly-and-operating-manual_1215813023.webp)
Assembly and connection
5.3.2 Dynamic pressure monitoring of the jaw end positions (variant "PM")
Dynamic pressure monitoring for the jaw end positions is
integrated via connections 1 and 4 on the bottom.
Connection 1 → monitoring outer end jaw position.
Connection 4 → monitoring inner end jaw position.
The max. pressure for the monitoring functions is 2 bar.
Limit volumetric flow to 10 l/min.
Pressure difference between stroke end positions min. 1 bar.
Circuit diagram for external workpiece clamping:
Connection
Signal output
Jaw end position open
Jaw end position CLOSED
Clamping position
Circuit diagram, pressure sensor
Connection
Jaw end position on
clamping force block
open
Jaw end position closed
Clamping force block
closed
Clamping position
Circuit diagram for internal workpiece clamping:
Connection
Clamping position
Clamping position
Signal output
Jaw end position open
Jaw end position closed
Connection
Jaw end position open
clamping force block
closed
Jaw end position closed
clamping force block
open
Circuit diagram, dynamic pressure
sensor
1
NOTES:
• For variants with a fixed jaw, only the outer jaw end position
can be monitored at connection 1 (see circuit diagram for
external workpiece clamping).
• It is not possible to monitor the clamping position with the
"PM" variant. The "IM" variant (inductive proximity switches) is
required for monitoring the clamping position.
23
04.00 | KSP3, KSP3-LH, KSP3-F | TANDEM Clamping Block | en | 1463318