02.00 | KSH3 IM | Assembly and Operating Manual | en | 1477686
33
Maintenance and care
7
Maintenance and care
7.1
Notes
Original spare parts
Only use original SCHUNK spare parts when replacing wearing
parts/spare parts.
Replacement of the housing and base jaws
The base jaws and the guides in the housing are matched to each
other. To replace these parts, send the entire product to SCHUNK
with a repair order.
7.2
Maintenance and lubrication intervals
The following maintenance work should be carried out after the
specified cycle numbers or, at the latest, according to the monthly
data.
Maintenance work
Interval [cycles/months]
Lubrication
10000/1
Basic cleaning
-/6
Leak test
5000/1
Regularly check inductive proximity switches for proper
functioning. Check for damage to connection cables, connection
plugs and the sensor head.
7.3
Greasing areas/lubricants
Greasing areas
Lubricant
Sliding surfaces body – base jaw
LINOMAX 200
Sliding surfaces base jaws– chuck piston
LINOMAX 200
Lubrication nipples
LINOMAX 200
Central lubrication
LINOMAX 200
All seals
RENOLIT HLT 2
Sliding surfaces cylinder piston – housing
RENOLIT HLT 2
(Product information for LINOMAX 200 can be requested from
SCHUNK)
Alternative lubricant
LINOMAX plus can also be used as an alternative to LINOMAX 200.
However, the specified clamping forces exclusively refer to the
LINOMAX 200 used by SCHUNK.
For LINOMAX plus, the clamping forces can be lower.